                                           ANALYSIS OF NON-IONIZING RADIATION
                                         FOR A 1.2 METER EARTH STATION ANTENNA

        THIS REPORT ANALYZES THE NON-IONIZING RADIATION LEVELS FOR AN EARTH STATION ANTENNA. THE OFFICES OF
        SCIENCE AND TECHNOLOGY BULLETIN NO. 65, EDITION 97-01, SPECIFIES THAT THE MAXIMUM LEVEL OF NON-IONIZING
        RADIATION THAT A PERSON MY BE EXPOSED TO OVER A SIX MINUTE PERIOD IS AN AVERAGE POWER DENSITY EQUAL TO
        5 mW/cm2 (FIVE MILLIWATTS PER CENTIMETER SQUARED). IT IS THE PURPOSE OF THIS REPORT TO DETERMINE THE
        POWER FLUX DENSITIES OF THE EARTH STATION ANTENNA IN THE FAR FIELD, NEAR FIELD, TRANSITION REGION,
        BETWEEN THE SUBREFLECTOR AND THE MAIN REFLECTOR SURFACE. AT THE MAIN REFLECTOR SURFACE AND
        BETWEEN THE ANTENNA EDGE AND THE GROUND.




                          THE FOLLOWING PARAMETERS WERE USED TO CALCULATE THE VARIOUS POWER FLUX
                       DENSITIES FOR THIS EARTH STATION.


Antenna Diameter,                                 (D)     =         1.20 meters                  120 cm

                                                                               2                        2
Antenna Surface area,                             (Sa)    =         1.13 meters             11309.73 cm

Feed Flange Diameter                              (Df)    =         7.62 cm                   0.0762 meters

                                                                            2                              2
Area of Feed Flange                               (Fa)    =        45.60 cm                    0.005 meters

Frequency in GHz                                                   14.25 GHz
Wavelength at Frequency                           ( )     =         2.11 cm                   0.0211 meters

Transmit Power at Flange                          (P)     =       100.00 Watts

Antenna Gain at Frequency                         (Ges)   =        43.10 dB
Gain converted to power ratio                                   20417.38

Antenna Aperture Efficiency                       (n)     =         0.65 Percentage / 100

1. Far Field Calculations:

Distance to the far field region                  (Rf)    =        41.04 meters

                                                                               2
On axis power density in the far field            (W f)             0.96 mW/cm


2. Near Field Calculations:

Extent of near field                              (Rn)             17.10 meters

                                                                               2
Near field power density                          (W n)             2.30 mW/cm


3. Transition Region Calculations:

The maximum power density in the transition region will not exceed that calculated for the near field
region. The power density in the near field region, as shown above, will not exceed                     2.30 mW/cm2

4. Region between main reflector & subreflector:

                                                                                                    2
Power density at feed flange                                  (W f)                   4385.61 mW/cm

5. Main Reflector Region:

                                                                                                    2
Power density at reflector surface                            (W s)                      3.54 mW/cm

6. Region Between Reflector & Ground:
At a distance of one antenna diameter or more
                                                                                                    2
Power density between reflector & ground                      (W g)                      0.02 mW/cm




                                                                            Table 1

                                                         Summary of Expected Radiation Levels

                                                Based on (5 mW/cm2 ) MPE for Controlled Environment

                                                                           Calculated Maximum
Region                                                                     Radiation Level (mW/cm2 )        Hazard Assessment

1. Far Field, (Rf)=                                                                      0.96               SATISFIES ANSI

2. Near Field, (Rn )=                                                                    2.30               SATISFIES ANSI

3. Transition Region, (Rt)                                                               2.30               SATISFIES ANSI
   Rn < Rt < Rf

4. Between Main Reflector
   and subreflector                                                                   4385.61               POTENTIAL HAZARD

5. Reflector Surface                                                                     3.54               SATISFIES ANSI

6. Between Antenna and Ground                                                            0.02               SATISFIES ANSI


It is the applicants responsibility to ensure that the public and operational
personnel are not exposed to the harmful levels of radiation.