Attachment RAD HAZ

This document pretains to SES-LIC-20110726-00870 for License on a Satellite Earth Station filing.

IBFS_SESLIC2011072600870_907854

EXHIBIT A1 - ANALYSIS OF NON-IONIZING RADIATION, 1.8 m Ku

HARMFUL LEVELS OF RADIATION WILL NOT EXIST IN REGIONS NORMALLY
OCCUPIED BY PERSONNEL.
     CRITERIA: ANSI SPECIFICATIONS REQUIRE THAT PERSONNEL NOT BE
                                                                    2
     EXPOSED TO LEVELS OF NON-IONIZING RADIATION EXCEEDING 5 mW / cm .

THE FOLLOWING ANALYSES SUPPORT THIS DETERMINATION:

FAR FIELD ANALYSIS:
ANTENNA DIAMETER           = 1.8 Meters
ANTENNA GAIN               = 47.0 dBi (lin 50,119)
LAMBDA                     = 3*108 Meters / 14.25*109 Hz = 0.0210526
EFFICIENCY                 = h = G/(p*D/l)2 = 0.708
POWER MAX AT FLANGE        = 500 Watts (27.0 dBW)
DISTANCE TO FAR FIELD      = 2*D2/l
                           = 6.48 / 0.0210526
                           = 307.8 Meters
ON-AXIS POWER DENSITY      = G*P/4*p*Far Field Distance2
                           = 50,119 * 500 / 12.56637 * 94,741
                           = 21.05 W/m2
                           = 2.11 mW/cm2
LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED


NEAR FIELD ANALYSIS (Parallel Beam Region & Transition Region):
PARALLEL BEAM REGION ANALYSIS:
DISTANCE TO END OF PARALLEL BEAM (CYLINDER) REGION:
                           = DIAMETER2 / 2.5 * l
                           = 3.24 / 0.0526315
                           = 61.6 Meters
POWER DENSITY AT END OF PARALLEL BEAM REGION
                           = P / CYLINDRICAL PARALLEL BEAM AREA
                           = 500 / 3.24
                           = 154.32 W / m2
                           = 15.4 mW / cm2
LEVEL IS GREATER THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED
ANTENNA IS MOUNTED 10’ IN THE AIR ON TRUCK, NO PERSONNEL WILL
OCCUPY THE PARALLEL BEAM REGION DURING OPERATION.

TRANSITION REGION ANALYSIS:
THIS REGION WILL DECREASE INVERSELY WITH DISTANCE BEGINNING AT THE
END OF THE PARALLEL BEAM REGION AND NOT EXCEED 15.4 mW / cm2


Exhibit A1-pg2


MAIN REFLECTOR ANALYSIS:
                           = P / REFLECTOR AREA
                           = 500 / 3.24
                           = 154.32 W / m2
                           = 15.4 mW/cm2
LEVEL IS GREATER THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED
ANTENNA IS MOUNTED 10’ IN THE AIR ON TRUCK, NO PERSONNEL WILL
OCCUPY THE MAIN REFLECTOR OR THE FEED TO REFLECTOR REGION
DURING OPERATION.

RF POWER WILL BE TURNED OFF DURING ANY ANTENNA MAINTENANCE
REQUIRING PERSONNEL TO OCCUPY ANY HAZARDOUS REGION BETWEEN
THE FEED HORN, REFLECTOR, AND TRANSITION ZONE.

AS A TRANSPORTABLE UNIT, PRECAUTIONS WILL BE TAKEN TO VERIFY THAT
THE ANTENNA IS NOT POINTING TOWARD ANY POPULATED AREA.

PREPARED AND SUBMITTED BY:



BASIL F. PINZONE, JR. 07/26/2011
TECHNICAL CONSULTANT


EXHIBIT A2 - ANALYSIS OF NON-IONIZING RADIATION, 2.4 m C-Band

HARMFUL LEVELS OF RADIATION WILL NOT EXIST IN REGIONS NORMALLY
OCCUPIED BY PERSONNEL.
     CRITERIA: ANSI SPECIFICATIONS REQUIRE THAT PERSONNEL NOT BE
     EXPOSED TO LEVELS OF NON-IONIZING RADIATION EXCEEDING 5 mW / cm2.

THE FOLLOWING ANALYSES SUPPORT THIS DETERMINATION:

FAR FIELD ANALYSIS:
ANTENNA DIAMETER           = 2.4 Meters
ANTENNA GAIN               = 41.8 dBi (lin 15,135)
LAMBDA                     = 3*108 Meters / 6.175*109 Hz = 0.048583
EFFICIENCY                 = h = G/(p*D/l)2 = 0.628
POWER MAX AT FLANGE        = 358 Watts (25.54 dBW)
DISTANCE TO FAR FIELD      = 2*D2/l
                           = 11.52 / 0.048583
                           =237.1 Meters
ON-AXIS POWER DENSITY      = G*P/4*p*Far Field Distance2
                           = 15,135 * 358 / 12.56637 * 56,216
                           = 7.67 W/m2
                           = 0.77 mW/cm2
LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED


NEAR FIELD ANALYSIS (Parallel Beam Region & Transition Region):
PARALLEL BEAM REGION ANALYSIS:
DISTANCE TO END OF PARALLEL BEAM (CYLINDER) REGION:
                           = DIAMETER2 / 2.5 * l
                           = 5.76 / 0.12146
                           = 47.42 Meters
POWER DENSITY AT END OF PARALLEL BEAM REGION
                           = P / CYLINDRICAL PARALLEL BEAM AREA
                           = 358 / 5.76
                           = 62.15 W / m2
                           = 6.22 mW / cm2
LEVEL IS GREATER THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED.
ANTENNA IS MOUNTED 8’ IN THE AIR. NO PERSONNEL WILL OCCUPY THE
PARALLEL BEAM REGION DURING OPERATION.

TRANSITION REGION ANALYSIS:
THIS REGION WILL DECREASE INVERSELY WITH DISTANCE BEGINNING AT THE
END OF THE PARALLEL BEAM REGION AND WILL NOT EXCEED 6.22 mW / cm2


Exhibit A2-pg2


MAIN REFLECTOR ANALYSIS:
                           = P / REFLECTOR AREA
                           = 358 / 5.76
                           = 62.15 W / m2
                           = 6.22 mW/cm2
LEVEL IS GREATER THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED.
ANTENNA IS MOUNTED 8’ IN THE AIR. NO PERSONNEL WILL OCCUPY THE MAIN
REFLECTOR OR THE FEED TO REFLECTOR REGION DURING OPERATION.

RF POWER WILL BE TURNED OFF DURING ANY ANTENNA MAINTENANCE
REQUIRING PERSONNEL TO OCCUPY ANY HAZARDOUS REGION BETWEEN
THE FEED HORN, SUB-REFLECTOR, REFLECTOR, AND TRANSITION ZONE.

AS A TRANSPORTABLE UNIT, PRECAUTIONS WILL BE TAKEN TO VERIFY THAT
THE ANTENNA IS NOT POINTING TOWARD ANY POPULATED AREA.


PREPARED AND SUBMITTED BY:



BASIL F. PINZONE, JR. 07/26/11
TECHNICAL CONSULTANT



Document Created: 2011-07-26 16:00:03
Document Modified: 2011-07-26 16:00:03

© 2024 FCC.report