Attachment Rad'n Hazard Study

This document pretains to SES-LIC-20100124-00110 for License on a Satellite Earth Station filing.

IBFS_SESLIC2010012400110_795568

                                                                                  Radiation Analysis


                            Analysis of Non-ionizing Radiation
                         For General Dynamics 1.80 Meter Antenna

This report analyzes the non-ioninizing radiation levels for an earth station using the VertexRSI
antenna. The equations used in these calculations are presented in the Office of Science and
Technology Bulletin No. 65, Oct. 1985 as revised in 1997 in Edition 97-01. The purpose of this
analysis is to determine the power flux densities in the far field, near field, transition region, between
the sub- and main-reflector surface, and between the antenna edges and ground. Per FCC R&O 96-
326, the maximum level of non-ionizing radiation is limited to a power density of 5 milliwatts per
square centimeter over any 6 minute in a controlled environment. The maximum level of non-ionizing
radiation is limited to a power density of 1 milliwatt per square centimeter over any 30 minutes in a
uncontrolled environment.

                                            Antenna Diameter            180   cm
                                      Antenna Aperture Area          25471    cm2
                                        Subreflector Diameter             0   cm
                                          Area of Subreflector            0   cm2
                                                    Frequency         14.25   GHz
                                                   Wavelength          2.10   cm
                              Total Transmit Power at Flange            500   Watts
                                                 Antenna Gain         45.90   dB
                                  Antenna Aperture Efficiency        53.8%
                 Height of Object to be cleared by main beam              3   m

Far Field Calculations

                         Distance to the beginning of far field       9249 cm
                                                                                 2
                         On axis power density in the far field      18.09 mW/cm

Near Field Calculations

                              Distance to the end of near field        3854 cm
                                                                                   2
                                    Near Field Power Density          42.24 mW/cm
                                     Controlled Environment:         Non-Compliant with FCC Limits
                                   Uncontrolled Environment:         Non-Compliant with FCC Limits

Transition Region Calculation

The transition region is located between the near and far field regions. As stated above, the power
density begins to decrease with distance in the transition region. While the power density decreases
inversely with distance in the transition region, the power density decreases inversely with the square
of the distance in the far field region. The maximum power density in the transition region will not
exceed that calculated for the near field region.




1/7/2010                                      Page 1 of 2


                                                                                  Radiation Analysis


Region between Main Reflector and Subreflector

Transmissions from the feed horn are directed toward the subreflector surface, and are reflected back
toward the main reflector. The energy density between the subreflector and main reflector surfaces
can be calculated by determining the power density at the subreflector surface.

                                                                                  2
                            Power density at subreflector edge          N/A mW/cm

Main Reflector Region

The power density in the main reflector region is determined in the same manner as the power
density in the subreflector above.

                                                                                  2
                      Power density at the main reflector edge        39.26 mW/cm

Region between Main Reflector and Ground

Assuming uniform illumination of the reflector surface, the power density between antenna and
ground can be calculated as follows:

                                                                                      2
                Power density between Reflector and Ground            19.63 mW/cm
                                    Controlled Environment:          Non-Compliant with FCC Limits
                                  Uncontrolled Environment:          Non-Compliant with FCC Limits

Safety region in front of Antenna

Considering walking along the antenna boresight, the distances one has to obtain from the antenna to
achieve safe power density levels are, respectively,

                    Controlled Environment; distance on-axis         175.95 m
                  Uncontrolled Environment; distance on-axis         393.44 m

Similarly, when a path is followed parallel to the antenna's boresight axis yet removed from the center
axis by a distance equal to the antenna diameter, the power density is reduced by at least 20 dB (per
Bulletin 65).
The safety region in front of the antenna is finally defined by the following distance from a vertical axis
through the antenna center as

                                                Elevation Angle    Minimum distance
                                                              5        33.2 m
                                                            10         16.6 m
                                                            20          8.3 m
                                                            30          5.5 m
                                                            40          4.1 m



1/7/2010                                       Page 2 of 2