Attachment Supplement Infor Rad

This document pretains to SES-LIC-20080204-00112 for License on a Satellite Earth Station filing.

IBFS_SESLIC2008020400112_620716

RADIATION HAZARD ANALYSIS AND REPORT


This exhibit contains a report of the analysis of the radio frequency (RF) hazard present
during the operation of the proposed radio and antenna system.

The hub facility will utilize an Andrew 3.7 m earth station antenna and a 200 watt power
amplifier.

While the radiation hazard analysis for the hub antenna was conducted using the full
output power of the power amplifier, it should be noted that in actual operation the output
power will typically be reduced by several dB.


Analysis of Non-Ionizing Radiation for a 3.7 m Earth Station System

This report analyzes the non-ionizing radiation levels for a 3.7 m earth station system.
The analysis and calculations performed in this report are in compliance with the
methods described in the FCC Office of Engineering and Technology Bulletin No. 65.

Bulletin No. 65 specifies that there are two separate tiers of exposure limits that are
dependant upon the situation in which the exposure takes place and/or the status of the
individuals who are subject to the exposure. The two tiers are General Population /
Uncontrolled environment, and an Occupational / Controlled environment.

The applicable exposure limit for the General Population / Uncontrolled environment at
this frequency of operation is 1 mW/cm^2.

The applicable exposure limit for the Occupational / Controlled environment at this
frequency of operation is 5 mW/cm^2.

Definition of terms

The terms are used in the formulas here are defined as follows:

Ssurface = maximum power density at the antenna surface
Snf = maximum near-field power density
St = power density in the transition region
Sff = power density (on axis)
Rnf = extent of near-field
Rff = distance to the beginning of the far-field
R = distance to point of interest
Pa = 200 W                     power amplifier maximum output in Watts
Lfs = 0.45 dB                  loss between amplifier and antenna input in dB
P = 180.314 W                  power input to the antenna in Watts
                               (200 W / 10^(0.45 dB / 10))
               2
A = 10.752 m                   physical area of the aperture antenna
G = 1.954 x 105                power gain relative to an isotropic radiator
D = 3.7 m                      diameter of antenna in meters
F = 14,250                     frequency in MHz
= 0.021 m                     wavelength in meters (300/FMHz )
= 0.64                        aperture efficiency


Antenna Surface. The maximum power density directly in front of an antenna (e.g., at
the antenna surface) can be approximated by the following equation:

Ssurface = (4 * P) / A

        = (4 * 180.314) / 10.752 m2

        = 67.08 W/m2

        = 6.708 mW/cm2


Near Field Region. In the near-field or Fresnel region, of the main beam, the power
density can reach a maximum before it begins to decrease with distance. The extent of
the near field can be described by the following equation (D and in same units):

Rnf     = D2 / (4 * )

        = 3.72 / (4 * 0.021)

        = 162.681 m


The magnitude of the on-axis (main beam) power density varies according to location in
the near field. However, the maximum value of the near-field, on-axis, power density
can be expressed by the following equation:

Snf     = (16 * * P) / (* D2)

        = (16 * 0.65 * 283.178) / (* 4.52)

        = 42.93 W/m2

        = 4.293 mW/cm2


Far-Field Region. The power density in the far-field or Fraunhofer region of the
antenna pattern decreases inversely as the square of the distance. The distance to the start
of the far field can be calculated by the following equation:

Rff     = (0.6 * D2) / 

        = (0.6 * 3.72) / 0.021

        = 390.435 m


The power density at the start of the far-field region of the radiation pattern can be
estimated by the equation:

Sff    = (P * G) / (4 * * Rff 2)

       = (180.314 * 1.954 x 105) / (4 * * 390.4352)

       = 0.78 W/m2

       = 0.078 mW/cm2


Transition Region. Power density in the transition region decreases inversely with
distance from the antenna, while power density in the far field (Fraunhofer region) of the
antenna decreases inversely with the square of the distance. The transition region will
then be the region extending from Rnf to R ff. If the location of interest falls within this
transition region, the on-axis power density can be determined from the following
equation:

St     = (Snf * Rnf) / R

       = (4.293 mW/cm2 * 162.681 m) / R

       = (698.416 m * mW/cm2) / R where R is the location of interest in meters


Summary of expected radiation levels for an Uncontrolled environment


Region                         Maximum Power Density                 Hazard Assessment

Far field (Rff ) = 390.435 m          0.078 mW/cm2                   Satisfies FCC MPE

Near field (Rnf) = 162.681 m          4.298 mW/cm2                   Potential Hazard

Transition region (Rt )
(Rt) = Rnf < Rt < Rff                 4.293 mW/cm2                   Potential Hazard

Main Reflector Surface (Ssurface)     6.708 mW/cm2                   Potential Hazard

Note, power density level in the area between the feed and the reflector surface is greater
than the reflector surface and is assumed to be a potential hazard.



Summary of expected radiation levels for a Controlled environment


Region                         Maximum Power Density                 Hazard Assessment

Far field (Rff ) = 390.435 m          0.078 mW/cm2                   Satisfies FCC MPE

Near field (Rnf) = 162.681 m          4.298 mW/cm2                   Satisfies FCC MPE

Transition region (Rt )
(Rt) = Rnf < Rt < Rff                 4.298 mW/cm2                   Satisfies FCC MPE

Main Reflector Surface (Ssurface)     6.708 mW/cm2                   Potential Hazard



Conclusions

The proposed earth station system will be located on a building rooftop with controlled
access and will be serviced by trained personnel. The radio and amplifier system will be
turned off when servicing the antenna system. Based on the above analysis it is
concluded that harmful radiation levels will not exist in regions normally occupied by the
public.

Note: The levels above are based on the full 200 W output power of the power amplifier
system. In actual operation the amplifier output level will typically be reduced by several
dB.



Document Created: 2008-02-07 11:04:18
Document Modified: 2008-02-07 11:04:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC