Attachment New Rad Haz Report

This document pretains to SES-LIC-20070928-01334 for License on a Satellite Earth Station filing.

IBFS_SESLIC2007092801334_607066

                                                                                   Exhibit
Radiation Hazard Report                                                            Page 1 of 4


      Analysis of Non-Ionizing Radiation for a 6.1-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 6.1-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                 Value             Units
     Antenna Diameter                D               Input                   6.1             m
     Antenna Surface Area          Asurface         π D2 / 4                29.22            m2
     Subreflector Diameter          Dsr              Input                  55.8             cm
     Area of Subreflector           Asr             π Dsr 2/4             2445.45            cm2
     Frequency                       F               Input                 14250             MHz
     Wavelength                      λ              300 / F              0.021053            m
     Transmit Power                  P               Input                 415.00            W
     Antenna Gain (dBi)             Ges              Input                   57.3            dBi
     Antenna Gain (factor)           G              10Ges/10              537031.8           n/a
     Pi                              π             Constant              3.1415927           n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.65            n/a


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 2 of 4




1.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                       Rff = 0.60 D2 / λ                   (1)
                                                                = 1060.5 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                 Sff = G P / (4 π Rff 2)             (2)
                                                                = 15.770 W/m2
                                                                = 1.577 mW/cm2

2.      Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                               Rnf = D2 / (4 λ)                    (3)
                                                                = 441.9 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                               Snf = 16.0 η P / (π D2)             (4)
                                                                = 36.814 W/m2
                                                                = 3.681 mW/cm2

3.      Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                   (5)
                                                               = 3.681 mW/cm2


                                                                              Exhibit
Radiation Hazard Report                                                       Page 3 of 4



4.      Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

     Power Density at the Subreflector                    Ssr = 4000 P / Asr                (6)
                                                              = 678.812 mW/cm2

5.      Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

     Power Density at the Main Reflector Surface      Ssurface = 4 P / Asurface             (7)
                                                               = 56.801 W/m2
                                                               = 5.680 mW/cm2


6.      Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

     Power Density between Reflector and Ground           Sg = P / Asurface                 (8)
                                                             = 14.200 W/m2
                                                             = 1.420 mW/cm2


                                                                                  Exhibit
Radiation Hazard Report                                                           Page 4 of 4



7.     Summary of Calculations

            Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                             Calculated Maximum
                                         Radiation Power Density Level
Region                                               (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1060.5 m)                    Sff        1.577              Potential Hazard
2. Near Field (Rnf = 441.9 m)                    Snf        3.681              Potential Hazard
3. Transition Region (Rnf < Rt < Rff)            St         3.681              Potential Hazard
4. Between Main Reflector and                    Ssr      678.812              Potential Hazard
    Subreflector
5. Main Reflector                                Ssurface   5.680              Potential Hazard
6. Between Main Reflector and Ground             Sg         1.420              Potential Hazard

             Table 5. Summary of Expected Radiation levels for Controlled Environment
                                            Calculated Maximum
                                           Radiation Power Density
Region                                         Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 1060.5 m)                   Sff         1.577            Satisfies FCC MPE
2. Near Field (Rnf = 441.9 m)                   Snf         3.681            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)           St          3.681            Satisfies FCC MPE
4. Between Main Reflector and                   Ssr      678.812              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface    5.680             Potential Hazard
6. Between Main Reflector and Ground            Sg          1.420            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



8.     Conclusions

Based on the above analysis it is concluded that harmful levels of radiation will not exist in regions
normally occupied by the public or the earth station's operating personnel. The transmitter will be
turned off during antenna maintenance so that the FCC MPE of 5.0 mW/cm2 will be complied with
for those regions with close proximity to the reflector that exceed acceptable levels.

The antenna will be located in a gated and fenced facility, where only personnel with knowledge of
the radiation hazard potential will have access.



Document Created: 2007-11-27 12:57:29
Document Modified: 2007-11-27 12:57:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC