        EXHIBIT A - ANALYSIS OF NON-IONIZING RADIATION

HARMFUL LEVELS OF RADIATION WILL NOT EXIST IN REGIONS NORMALLY
OCCUPIED BY PERSONNEL.
     CRITERIA: ANSI SPECIFICATIONS REQUIRE THAT PERSONNEL NOT BE
     EXPOSED TO LEVELS OF NON-IONIZING RADIATION EXCEEDING 5 mW / cm2.

THE FOLLOWING ANALYSES SUPPORT THIS DETERMINATION:

FAR FIELD ANALYSIS:

EFFICIENCY                 = η = G/(π*D/λ)2 = 0.605
ANTENNA GAIN               = 49.0 dBi (lin 79,433)
ANTENNA DIAMETER           = 2.4 Meters
LAMBDA                     = 3*108 Meters / 14.25*109 Hz = 0.0210526
POWER MAX AT FLANGE        = 40 Watts (16.0 dBW)
DISTANCE TO FAR FIELD      = 2*D2/λ
                           = 11.52 / 0.0210526
                           = 547 Meters
ON-AXIS POWER DENSITY      = G*P/4*π*Far Field Distance2
                           = 79,433 * 40 / 12.56637 * 299,209
                           = 0.845 W/m2
                           = 0.085 mW/cm2
LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED


NEAR FIELD ANALYSIS (Parallel Beam Region & Transition Region):

PARALLEL BEAM REGION ANALYSIS:
DISTANCE TO END OF PARALLEL BEAM (CYLINDER) REGION:
                           = DIAMETER2 / 2.5 * λ
                           = 5.76 / 0.0526315
                           = 109 Meters
POWER DENSITY AT END OF PARALLEL BEAM REGION
                           = P / CYLINDRICAL PARALLEL BEAM AREA
                           = 40 / 4.52
                           = 8.85 W / m2
                           = 0.089 mW / cm2
LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED

TRANSITION REGION ANALYSIS:
THIS REGION WILL DECREASE INVERSELY WITH DISTANCE BEGINNING AT THE
END OF THE PARALLEL BEAM REGION AND REDUCE TO 0.085 mW / cm2


MAIN REFLECTOR ANALYSIS:
                           = P / REFLECTOR AREA
                           = 40 / 4.52
                           = 8.85 W / m2
                           = 0.089 mW/cm2
LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED


FEED TO SUB-REFLECTOR / REFLECTOR ANALYSIS:
POWER DENSITY AT FEED FLANGE = P / FEED AREA
                         = 40 / 0.2172
                         = 184 W/m2
                         = 18.4 mW/cm2

LEVEL IS GREATER THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED.
NO PERSONNEL WILL OCCUPY THE FEED TO SUB TO MAIN REFLECTOR
REGION DURING OPERATION.

RF POWER WILL BE TURNED OFF DURING ANY ANTENNA MAINTENANCE
REQUIRING PERSONNEL TO OCCUPY ANY HAZARDOUS REGION BETWEEN
THE FEED HORN, SUB-REFLECTOR, REFLECTOR.




PREPARED AND SUBMITTED BY:



BASIL F. PINZONE, JR. 08/01/2006