Attachment Exhibit A

This document pretains to SES-LIC-20050427-00503 for License on a Satellite Earth Station filing.

IBFS_SESLIC2005042700503_430026

                               RADIATION HAZARD CALCULATIONS FOR             1.8 meter EARTH STATION



              Nomenclature              Formula                     Value Unit



       INPUT PARAMETERS

D = Antenna Diameter                                                  1.8 meters

d = Diameter of Feed Mouth                                          0.049 meters

P = Max Power into Antenna                                             8.5 Watts



n = Apperture Effeciency                                             67%

k = Wavelength @ 30 GHz                                            0.0100 meters



      CALCULATED VALUES

A = Area of Reflector                  PI*D^2/4                     2.545 meters^2

l = Length of Near Field                D^2/4k                         81 meters

L = Beginning of Far Field             0.6D^2/k                      194 meters

G = Antenna Gain @ 30 GHz             n(PI*D/k)^2                 214,278 53.3 dBi



a = Area of Feed Mouth                  PI*d^2/4                   0.0019 meters^2



                  POWER DENSITY CALCULATIONS



                                                Maximum Power Density in Region
                Region                                                             Hazard Assessment
                                        Formula               Value (mW/cm^2) (FCC MPE Limit = 5 mW/cm^2)



1 Near Field                             4nP/A                        0.90           < FCC MPE Limit

2 Far Field                          GP/(4(PI)L^2)                    0.38           < FCC MPE Limit

3 Transition                        <= Nr Fld Region                  0.90           < FCC MPE Limit

4 Near Reflector Surface                 4P/A                         1.34           < FCC MPE Limit

5 Between Reflector & Ground              P/A                         0.33           < FCC MPE Limit

6 Between Reflector and Feed             4P/a                      1803.0         > FCC MPE Limit ( See Text )


                                                   RADIATION HAZARD ANALYSIS
                                                    1.8 meter EARTH STATION

   This analysis calculates the non-ionizing radiation levels due to transmission from the earth station.
The Office of Engineering and Technology (OET) Bulletin No. 65 specifies that the Maximum Permissible
Exposure (MPE) limit for the persons in an Occupational/Controlled environment to non-ionizing radiation
averaged over six minutes, is a power density of 5 milli-Watts per centimeter squared.

   The analysis estimates the maximum power density levels in the vicinity of the antenna for six regions:
near field; far field; transition zone; near the reflector surface; between the reflector and the ground; and
between the feed mouth and the reflector.

   A brief discusion for each region is given below. The attached table shows the assumptions, formulae and
calculations for all cases.



1. NEAR FIELD REGION
   The near field (or Fresnel region) is essentially a cylindrical region with its axis co-incident with the
antena boresight. The diameter of this cylinder is equal to that of the antenna. According to OET Bulletin
No. 65, its length is equal to the square of the diameter divided by four times the wavelength. The maximum
value of the on-axis power density is calculated using the equation given in the Bulletin.

2. FAR FIELD REGION
    The far field (or Fraunhofer region) extends outwards from a distance equal to 0.6 times the square of the
reflector diameter divided by the wavelength, according to OET Bulletin No. 65. Power density varies inversely
as the square of the distance. The maximum value of the power density is calculated using the equation given
in the Bulletin.

3. TRANSITION REGION
   The transition region between the near field and the far field regions will have a power density that
maximum essentially decreases inversely as distance. In any case, the maximum power density will not exceed
the value calculated for the near field region, for the purpose of evaluating potential exposure.

4. REGION NEAR REFLECTOR SURFACE
   The power density in the region near the reflector surface can be estimated as equal to four times the power
divided by the area of the reflector surface, assuming that the illumination is uniform and that it would be
possible to intercept equal amounts of energy radiated towards and reflected from the reflector surface.

5. REGION BETWEEN REFLECTOR AND GROUND
   The power density in the region between the reflector and the ground can be estimated as equal to the power
divided by the area of the reflector surface, assuming even illumination over the reflector.

6. REGION BETEEN THE FEED MOUTH AND REFLECTOR
   The radiation from the feed is essentially confined to a conical region whose vertex is located at the
feed mouth and extends to the reflector. Power density is maximum at the feed mouth, and can be estimated
as four times the output power divided by the area of the feed mouth.

   The analysis shows that the power density levels will never exceed the FCC MPE limit even during periods
of maximum output, except in the region between the feed and the reflector. To ensure compliance with the
FCC MPE limit, the earth station transmitter will be turned off whenever maintenance and repair personnel are
required to work within this potentially hazardous area.