  EXHIBIT A - ANALYSIS OF NON-IONIZING RADIATION, 4.8 Meters

HARMFUL LEVELS OF RADIATION WILL NOT EXIST IN REGIONS NORMALLY
OCCUPIED BY PERSONNEL.
     CRITERIA: ANSI SPECIFICATIONS REQUIRE THAT PERSONNEL NOT BE
     EXPOSED TO LEVELS OF NON-IONIZING RADIATION EXCEEDING 5 mW / cm2.

THE FOLLOWING ANALYSES SUPPORT THIS DETERMINATION:

FAR FIELD ANALYSIS:
ANTENNA DIAMETER           = 4.8 Meters
ANTENNA GAIN               = 48.1 dBi (lin 64,565)
LAMBDA                     = 3*108 Meters / 6.175*109 Hz = 0.048583
EFFICIENCY                 = η = G/(π*D/λ)2 = 0.67
POWER MAX AT FLANGE        = 450 Watts (26.5 dBW)
DISTANCE TO FAR FIELD      = 2*D2/λ
                           = 46.08 / 0.048583
                           =948.5 Meters
ON-AXIS POWER DENSITY      = G*P/4*π*Far Field Distance2
                           = 64,565 * 450 / 12.56637 * 758,792
                           = 2.57 W/m2
                           = 0.257 mW/cm2

LEVEL IS LESS THAN THE 5 mW/cm2 MAXIMUM ANSI LEVEL PERMITTED


NEAR FIELD ANALYSIS (Parallel Beam Region & Transition Region):

PARALLEL BEAM REGION ANALYSIS:
DISTANCE TO END OF PARALLEL BEAM (CYLINDER) REGION:
                         = DIAMETER2 / 2.5 * λ
                         = 23.04 / 0.12146
                         = 189.7 Meters
POWER DENSITY AT END OF PARALLEL BEAM REGION
                         = P / CYLINDRICAL PARALLEL BEAM AREA
                         = 450 / 18.1
                         = 24.86 W / m2
                         = 2.49 mW / cm2

LEVEL IS LESS THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED
ANTENNA IS MOUNTED 55’ IN THE AIR ON A SECURED ROOFTOP. NO
PERSONNEL WILL OCCUPY THE PARALLEL BEAM REGION DURING OPERATION.


Exhibit A-pg2

TRANSITION REGION ANALYSIS:
THIS REGION WILL DECREASE INVERSELY WITH DISTANCE BEGINNING AT THE
END OF THE PARALLEL BEAM REGION AND WILL NOT EXCEED 2.49 mW / cm2


MAIN REFLECTOR ANALYSIS:
                            = P / REFLECTOR AREA
                            = 450 / 18.1
                            = 24.8 W / m2
                            = 2.48 mW/cm2

LEVEL IS LESS THAN THE 5 mW/m2 MAXIMUM ANSI LEVEL PERMITTED.
ANTENNA IS MOUNTED 55’ ABOVE GROUND ON A SECURED ROOFTOP.

NO PERSONNEL WILL OCCUPY THE MAIN REFLECTOR OR THE FEED TO
REFLECTOR REGION DURING OPERATION.


RF POWER WILL BE TURNED OFF DURING ANY ANTENNA MAINTENANCE
REQUIRING PERSONNEL TO OCCUPY ANY HAZARDOUS REGION BETWEEN
THE FEED HORN, SUB-REFLECTOR AND REFLECTOR.

PRECAUTIONS WILL BE TAKEN TO VERIFY THAT THE ANTENNA IS NOT
POINTING TOWARD ANY POPULATED AREA.