Attachment radhad

This document pretains to SES-LIC-20030127-00082 for License on a Satellite Earth Station filing.

IBFS_SESLIC2003012700082_307262

                                                                                  Exhibit B
Radiation Hazard Report                                                           Page 1 of 4


      Analysis of Non-Ionizing Radiation for a 4.6-Meter Earth
                          Station System
This report analyzes the non-ionizing radiation levels for a 4.6-meter earth station system. The
analysis and calculations performed in this report comply with the methods described in the FCC
Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in 1997
in Edition 97-01. The radiation safety limits used in the analysis are in conformance with the FCC
R&O 96-326. Bulletin No. 65 and the FCC R&O specifies that there are two separate tiers of
exposure limits that are dependant on the situation in which the exposure takes place and/or the
status of the individuals who are subject to the exposure. The Maximum Permissible Exposure
(MPE) limits for persons in a General Population/Uncontrolled environment are shown in Table 1.
The General Population/Uncontrolled MPE is a function of transmit frequency and is for an
exposure period of thirty minutes or less. The MPE limits for persons in an
Occupational/Controlled environment are shown in Table 2. The Occupational MPE is a function of
transmit frequency and is for an exposure period of six minutes or less. The purpose of the
analysis described in this report is to determine the power flux density levels of the earth station in
the far-field, near-field, transition region, between the subreflector or feed and main reflector
surface, at the main reflector surface, and between the antenna edge and the ground and to
compare these levels to the specified MPEs.

               Table 1. Limits for General Population/Uncontrolled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              0.2
                         300-1500                  Frequency (MHz)*(0.8/1200)
                       1500-100,000                           1.0

                    Table 2. Limits for Occupational/Controlled Exposure (MPE)
                  Frequency Range (MHz)          Power Density (mW/cm2)
                          30-300                              1.0
                         300-1500                  Frequency (MHz)*(4.0/1200)
                       1500-100,000                           5.0

          Table 3. Formulas and Parameters Used for Determining Power Flux Densities
     Parameter                    Symbol           Formula                  Value         Units
     Antenna Diameter                D               Input                   4.6          m
     Antenna Surface Area          Asurface         π D2 / 4                16.62         m2
     Subreflector Diameter          Dsr              Input                   61.6         cm
     Area of Subreflector           Asr             π Dsr 2/4             2980.24         cm2
     Frequency                       F               Input                 14250          MHz
     Wavelength                      λ              300 / F               0.021053        m
     Transmit Power                  P               Input                  50.10         W
     Antenna Gain (dBi)             Ges              Input                   55.4         dBi
     Antenna Gain (factor)           G              10Ges/10              346736.8        n/a
     Pi                              π             Constant              3.1415927        n/a
     Antenna Efficiency              η             Gλ2/(π2D2)                0.74         n/a


                                                                                  Exhibit B
Radiation Hazard Report                                                           Page 2 of 4




1.      Far Field Distance Calculation

The distance to the beginning of the far field can be determined from the following equation:

     Distance to the Far Field Region                       Rff = 0.60 D2 / λ                   (1)
                                                                = 603.1 m

The maximum main beam power density in the far field can be determined from the following
equation:

     On-Axis Power Density in the Far Field                 Sff = G P / (4 π Rff 2)             (2)
                                                                = 3.801 W/m2
                                                                = 0.380 mW/cm2

2.      Near Field Calculation

Power flux density is considered to be at a maximum value throughout the entire length of the
defined Near Field region. The region is contained within a cylindrical volume having the same
diameter as the antenna. Past the boundary of the Near Field region, the power density from the
antenna decreases linearly with respect to increasing distance.

The distance to the end of the Near Field can be determined from the following equation:

     Extent of the Near Field                               Rnf = D2 / (4 λ)                    (3)
                                                                = 251.3 m

The maximum power density in the Near Field can be determined from the following equation:

     Near Field Power Density                               Snf = 16.0 η P / (π D2)             (4)
                                                                = 8.873 W/m2
                                                                = 0.887 mW/cm2

3.      Transition Region Calculation

The Transition region is located between the Near and Far Field regions. The power density
begins to decrease linearly with increasing distance in the Transition region. While the power
density decreases inversely with distance in the Transition region, the power density decreases
inversely with the square of the distance in the Far Field region. The maximum power density in
the Transition region will not exceed that calculated for the Near Field region. The power density
calculated in Section 1 is the highest power density the antenna can produce in any of the regions
away from the antenna. The power density at a distance Rt can be determined from the following
equation:

     Transition Region Power Density                        St = Snf Rnf / Rt                   (5)
                                                               = 0.887 mW/cm2


                                                                              Exhibit B
Radiation Hazard Report                                                       Page 3 of 4



4.      Region between the Main Reflector and the Subreflector

Transmissions from the feed assembly are directed     toward the subreflector surface, and are
reflected back toward the main reflector. The most    common feed assemblies are waveguide
flanges, horns or subreflectors. The energy between   the subreflector and the reflector surfaces
can be calculated by determining the power density    at the subreflector surface. This can be
determined from the following equation:

     Power Density at the Subreflector                    Ssr = 4000 P / Asr                (6)
                                                              = 67.243 mW/cm2

5.      Main Reflector Region

The power density in the main reflector is determined in the same manner as the power density at
the subreflector. The area is now the area of the main reflector aperture and can be determined
from the following equation:

     Power Density at the Main Reflector Surface      Ssurface = 4 P / Asurface             (7)
                                                               = 12.058 W/m2
                                                               = 1.206 mW/cm2


6.      Region between the Main Reflector and the Ground

Assuming uniform illumination of the reflector surface, the power density between the antenna and
the ground can be determined from the following equation:

     Power Density between Reflector and Ground           Sg = P / Asurface                 (8)
                                                             = 3.015 W/m2
                                                             = 0.301 mW/cm2


                                                                                 Exhibit B
Radiation Hazard Report                                                          Page 4 of 4



7.     Summary of Calculations

           Table 4. Summary of Expected Radiation levels for Uncontrolled Environment
                                            Calculated Maximum
                                        Radiation Power Density Level
Region                                              (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 603.1 m)                    Sff        0.380            Satisfies FCC MPE
2. Near Field (Rnf = 251.3 m)                   Snf        0.887            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)           St         0.887            Satisfies FCC MPE
4. Between Main Reflector and                   Ssr       67.243              Potential Hazard
    Subreflector
5. Main Reflector                               Ssurface   1.206              Potential Hazard
6. Between Main Reflector and Ground            Sg         0.301            Satisfies FCC MPE

            Table 5. Summary of Expected Radiation levels for Controlled Environment
                                           Calculated Maximum
                                          Radiation Power Density
Region                                        Level (mW/cm2)               Hazard Assessment
1. Far Field (Rff = 603.1 m)                   Sff         0.380            Satisfies FCC MPE
2. Near Field (Rnf = 251.3 m)                  Snf         0.887            Satisfies FCC MPE
3. Transition Region (Rnf < Rt < Rff)          St          0.887            Satisfies FCC MPE
4. Between Main Reflector and                  Ssr       67.243              Potential Hazard
    Subreflector
5. Main Reflector                              Ssurface    1.206            Satisfies FCC MPE
6. Between Main Reflector and Ground           Sg          0.301            Satisfies FCC MPE

It is the applicant's responsibility to ensure that the public and operational personnel are not
exposed to harmful levels of radiation.



8.     Conclusions

Based on the above analysis it is concluded that the FCC MPE guidelines have been exceeded (or
met) in the regions of Table 4 and 5. The applicant proposes to comply with the MPE limits by one
or more of the following methods.

The earth station will be located in a Gated and Fenced facility with secured access in and around
the proposed antenna. The extent of the facilities controlled environment will extend to cover the
area around the antenna and ensure the public will not have access to those areas where the 1
mW/cm**2 standard is exceeded.

Finally, occupational exposure will be limited, and the transmitter will be turned off during periods
of maintenance, so that the MPE standard of 5.0 mw/cm**2 will be complied with for those regions
in close proximity to the main reflector, and subreflector, which could be occupied by operating
personnel.



Document Created: 2003-03-10 16:37:21
Document Modified: 2003-03-10 16:37:21

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC