                                                            Radiation Hazard Analysis

                                         Operator:              SES
                              Location Designation:             MCI Mt Jackson                    FCC Callsign:
                                           County:              Shenandoah                             SES ID:
                                             Town:              Quicksburg                                STA:
                                         State/Zip:             VA             22847
                           Input Values                             Value          Unit                                Band          Frequency
                                D = Aperture Diameter                9.10            Meters                             L            1000-2000
                             d = Subreflector Diameter               0.56            Meters                              S           2000-4000
                                    G = Antenna Gain                 66.4                dBi                            C            4000-8000
                                     FCC Designation                  Ka             Band                               X           8000-12500
                                        F = Frequency               28.000           GHz                                Ku          12500-18000
                          P = Transmitter Power Watts:               150             Watts                              K           18000-25500
                    R ua = closest point to uncontrolled area         50            meters                              Ka          26500-40000
                    Elevation angle at closest point R ua             10            Degrees                             O           40000-50000
                                          Height (AGL)              12.00           meters                              V           50000-75000

                   OET 65 Calculated Values                       Formula            Value            Unit
                                                                      c
                                         λ= Wavelength                               0.0107     meters
                                                                      F
                                     G = Antenna Gain              10 (G/10)      4365158.322   (W) linear
                                                                   Gl2/4p
                            h = Apperture Efficiency                                     61%    percentage
                                                                    pD2/4
                                 A = Area of reflector               pR2            65.039      meters 2
                              a = area of subreflector                pr2          2463.009     cm 2
                                                                      D2           1933.522     meters
                             R nf = Near-Field Region
                                                                      4l             336        Meters AGL
                                                                     >Rnf          1933.522     >meters
                              R t = Transition Region
                                                                     <Rff          4640.454     <meters
                                                                    0.6D2          4640.454     meters
                               R ff = Far Field Region
                                                                       l             806        Meters AGL

                                                                                                                           Exposure Limits
                Radiation Analysis Zone                           Formula            Level           Value        General Public   Occupational
                                                                                                                   <1mW/cm2         <5mW/cm2
                                                                      4P                                          >FCC MPE See     >FCC MPE See
       1                           Power Subreflector                               243.605         mW/cm2
                                                                       a                                             Note 1           Note 2
                                                                      4P
       2                               Antenna Surface                               0.923          mW/cm2          <FCC MPE         <FCC MPE
                                                                       A
                                                                       P
       3                      Main Reflector Ground                                  0.231          mW/cm2          <FCC MPE         <FCC MPE
                                                                       A
                                                                     4h P
       4            S nf =Near-Field Power Density                                   0.565          mW/cm2          <FCC MPE         <FCC MPE
                                                                       A
       5        S t = Max Transition Power Density                   < Snf           0.565          mW/cm2          <FCC MPE         <FCC MPE
                                                                      PG
       6         S ff = Max Far field Power Density                                  0.242          mW/cm2          <FCC MPE         <FCC MPE
                                                                    4pRff2
       7           Off Access Level Near Field                    Snf - 20 dB       0.00565         mW/cm2          <FCC MPE         <FCC MPE

      Notes
           1. The antenna is installed in a controlled location access is restricted to authorized personnel only. The antenna is
              marked with RF Radiation Hazard signage.
           2. Inside the controlled area, MPE levels exceed the MPE exposure for occupational levels. The levels will be reduced
              to safe MPE by removing power to the transmitters when work is performed on or around the antenna. This area
              can only be accessed by qualified personnel.
           3. The field develops 12 meters above ground level at the minimum elevation angle which is not accessable to the
              general public.