Attachment Exhibit C

This document pretains to SES-AMD-20150211-00073 for Amended Filing on a Satellite Earth Station filing.

IBFS_SESAMD2015021100073_1076096

                                          ISAT US Inc.
                                         FCC Form 312
                                            Exhibit C
                                    Response to Question Q28



1. Radiation Hazard Analysis for the antenna manufactured by Intellian,
model: GX60
This section analyzes the non-ionizing radiation levels for the Intellian GX60 earth station included in this
application. The analysis and calculations performed in this Exhibit comply with the methods described
in the FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and revised in
1997 in Edition 97-01.
Bulletin No. 65 and the FCC R&O 96-326 specifies two Maximum Permissible Exposure (MPE) limits
that are dependent on the situation in which the exposure takes place and/or the status of the individuals
who are subject to the exposure. These are described below:

    •   General Population/Uncontrolled environment MPE limit is 1 mW/cm2. The General Population /
        Uncontrolled MPE is a function of transmit frequency and is for an exposure period of thirty
        minutes or less.
    •   Occupational/Controlled environment MPE limit is 5 mW/cm2. The Occupational MPE is a
        function of transmit frequency and is for an exposure period of six minutes or less.
The analysis provided in this report determined the power flux density levels of the earth station in the 1)
far-field, 2) near-field, 3) transition region, 4) region between the feed and main reflector surface, 5) at
the main reflector surface, and 6) between the antenna edge and the ground.



Section 1.1 – Detailed calculations


Input Parameter                                        Value          Units            Symbol
Antenna Diameter                                       0.65           m                D
Antenna Transmit Gain                                  43.9           dBi              G
Transmit Frequency                                     30000          MHz              f
Antenna Feed Flange Diameter                           4              cm               d
Power Input to the Antenna                             5              Watts            P

Calculated Parameter                                   Value          Units            Symbol     Formula
Antenna Surface Area                                   0.3318         m²               A          πD²/4
Area of Antenna Flange                                 19.2437        cm²              a          πd²/4
Antenna Efficiency                                     0.5887         real             η          gλ²/(π²D²)
Gain Factor                                            24547.0892     real             g          10^(G/10)
Wavelength                                             0.0100         m                λ          300/f


Antenna Field Distances
Calculated Parameter                                 Value          Units           Symbol     Formula
Near-Field Distance                                  10.5625        m               Rnf        D²/(4λ)
Distance to Far-Field                                25.35          m               Rff        0.6D²/λ
Distance of Transition Range                         10.5625        m               Rt         Rt=Rnf


Power Flux Density
Calculated Parameter                                 Value          Units           Symbol     Formula
Power Density in the Near Field                      3.5483         mW/cm²          Snf        16ηP/(πD²)
Power Density in the Far Field                       1.5199         mW/cm²          Sff        gP/(4πRff²)
Power Density in the Transition Region               3.5483         mW/cm²          St         Snf*Rnf/Rt
Power Density at the Feed Flange                     1039.3038      mW/cm²          Sfa        4P/a
Power Density at Main Reflector                      6.0273         mW/cm²          Ssurface   4P/A
Power Density between Reflector and Ground           1.5068         mW/cm²          Sg         P/A




Section 1.2 – Summary of Results


Region                            Calculated     Limit Controlled    Limit Uncontrolled
                                    Power          Environment         Environment
                                   Density         ≤ 5 mW/cm2           ≤ 1 mW/cm2
                                  (mW/cm2)
Near Field                          3.5483          meets limit         exceeds limit
Far Field                           1.5199          meets limit         exceeds limit
Transition Region                   3.5483          meets limit         exceeds limit
Feed Flange                       1039.3038        exceeds limit        exceeds limit
Main Reflector                      6.0273         exceeds limit        exceeds limit
Between Reflector and Ground        1.5068          meets limit         exceeds limit


As summarized in the above tables, the Intellian GX60 antenna meets the FCC’s MPE levels for
controlled environments except for at the feed flange as well as at the main reflector. Since the antenna
will be enclosed within a radome, these areas will not be accessible while the antenna is in operation.
Training of personnel with access to the antenna would include consideration of the operation mode of the
antenna and information on how to prevent radiation exposure, including disabling the communications
system. When maintenance of the antenna is required and the radome is removed, the trained technicians
will turn off the transmit power before performing work in these areas. In addition, the antenna will be
installed at an elevation that is not accessible by the general population on the vessels, and any areas
where the limits for uncontrolled environments could be exceeded will be restricted to trained personnel.
Therefore, the general population will be protected.
In conclusion, the results show that the Intellian GX60 antenna, in a controlled environment, and under
the proper mitigation procedures, meets the guidelines specified in § 1.1310 of the Regulations.


Moreover, the applicant agrees to take all necessary measures to ensure that the antenna does not create
potential exposure of humans to radiofrequency radiation in excess of the FCC exposure limits.



2. Radiation Hazard Analysis for the antenna manufactured by Intellian,
model: GX100
This section analyzes the non-ionizing radiation levels for the Intellian GX100 earth station included in
this application. The analysis and calculations performed in this Exhibit comply with the methods
described in the FCC Office of Engineering and Technology Bulletin, No. 65 first published in 1985 and
revised in 1997 in Edition 97-01.
Bulletin No. 65 and the FCC R&O 96-326 specifies two Maximum Permissible Exposure (MPE) limits
that are dependent on the situation in which the exposure takes place and/or the status of the individuals
who are subject to the exposure. These are described below:

    •   General Population/Uncontrolled environment MPE limit is 1 mW/cm2. The General Population /
        Uncontrolled MPE is a function of transmit frequency and is for an exposure period of thirty
        minutes or less.
    •   Occupational/Controlled environment MPE limit is 5 mW/cm2. The Occupational MPE is a
        function of transmit frequency and is for an exposure period of six minutes or less.
The analysis provided in this report determined the power flux density levels of the earth station in the 1)
far-field, 2) near-field, 3) transition region, 4) region between the feed and main reflector surface, 5) at
the main reflector surface, and 6) between the antenna edge and the ground.



Section 2.1 – Detailed calculations


Input Parameter                                        Value          Units            Symbol
Antenna Diameter                                       1.03           m                D
Antenna Transmit Gain                                  47.6           dBi              G
Transmit Frequency                                     30000          MHz              F
Antenna Feed Flange Diameter                           5.8            Cm               d
Power Input to the Antenna                             5              Watts            P

Calculated Parameter                                   Value          Units            Symbol     Formula
Antenna Surface Area                                   0.8332         m²               A          πD²/4
Area of Antenna Flange                                 26.420         cm²              a          πd²/4
Antenna Efficiency                                     0.5496         Real             η          gλ²/(π²D²)
Gain Factor                                            57543.9937     Real             g          10^(G/10)
Wavelength                                             0.0100         m                λ          300/f

Antenna Field Distances
Calculated Parameter                                   Value          Units            Symbol     Formula
Near-Field Distance                                    26.5225        m                Rnf        D²/(4λ)


Distance to Far-Field                                  63.654         m               Rff        0.6D²/λ
Distance of Transition Range                           26.5225        m               Rt         Rt=Rnf




Power Density
Calculated Parameter                                   Value          Units           Symbol     Formula
Power Density in the Near Field                        1.3193         mW/cm²          Snf        16ηP/(πD²)
Power Density in the Far Field                         0.5651         mW/cm²          Sff        gP/(4πRff²)
Power Density in the Transition Region                 1.3193         mW/cm²          St         Snf*Rnf/Rt
Power Density at the Feed Flange                       757.0018       mW/cm²          Sfa        4P/a
Power Density at Main Reflector                        2.4004         mW/cm²          Ssurface   4P/A
Power Density between Reflector and Ground             0.6001         mW/cm²          Sg         P/A



Section 2.2 – Summary of Results


Region                             Calculated     Limit Controlled     Limit Uncontrolled
                                     Power          Environment          Environment
                                    Density
                                                    ≤ 5 mW/cm2            ≤ 1 mW/cm2
                                   (mW/cm2)

Near Field                           1.3193          meets limit          exceeds limit

Far Field                            0.5651          meets limit           meets limit
Transition Region                    1.3193          meets limit          exceeds limit

Feed Flange                         757.0018        exceeds limit         exceeds limit

Main Reflector                       2.4004          meets limit          exceeds limit

Between Reflector and Ground         0.6001          meets limit           meets limit


As summarized in the above table, the Intellian GX100 antenna meets the FCC’s MPE levels for
controlled environments except for at the feed flange for the antenna. Since the antenna will be enclosed
within a radome, the feed flange area will not be accessible while the antenna is in operation. Training of
personnel with access to the antenna would include consideration of the operation mode of the antenna
and information on how to prevent radiation exposure, including disabling the communications system.
When maintenance of the antenna is required and the radome is removed, the trained technicians will turn
off the transmit power before performing work in these areas. In addition, the antenna will be installed at
an elevation that is not accessible by the general population on the vessels, and any areas where the limits
for uncontrolled environments could be exceeded will be restricted to trained personnel. Therefore, the
general population will be protected.


In conclusion, the results show that the Intellian GX100 antenna, in a controlled environment, and under
the proper mitigation procedures, meets the guidelines specified in § 1.1310 of the Regulations.
Moreover, the applicant agrees to take all necessary measures to ensure that the antenna does not create
potential exposure of humans to radiofrequency radiation in excess of the FCC exposure limits.



Document Created: 2015-02-05 13:43:46
Document Modified: 2015-02-05 13:43:46

© 2024 FCC.report