DISH Operating LLC,

LETTER submitted by DISH Operating L.L.C.

Section 1.1204(a)(10(ii) Letter

2012-10-09

This document pretains to SAT-MOD-20100329-00058 for Modification on a Satellite Space Stations filing.

IBFS_SATMOD2010032900058_970649

      Stephanie A. Roy
      202 429 6278
      sroy@steptoe.com

      1330 Connecticut Avenue, NW
      Washington, DC 20036-1795
      202 429 3000 main
      www.steptoe.com




October 9, 2012

VIA IBFS

Marlene H. Dortch
Secretary
Federal Communications Commission
445 12th Street, SW
Washington, DC 20554

Re:       DISH Operating L.L.C.; File Nos. SAT-MOD-20100329-00058, SAT-AMD-20100610-00127
          (Call Sign 2740)


Dear Ms. Dortch:

       With this letter, and pursuant to Section 1.1204(a)(10)(ii) of the Commission’s rules, DISH
Operating LLC (“DISH”) reports on a telephone call held between representatives of DISH and Karl
Kensinger and Chip Fleming of the International Bureau on matters relating to the above-referenced file
numbers. In addition to the undersigned, also present on the call were Alison Minea, Darren Hamilton,
and Shane Scott on behalf of DISH.

         On the call, Bureau staff asked DISH to provide additional information with respect to data
submitted to the Commission in DISH’s September 28, 2012 response to a September 13, 2012 inquiry
received from the Satellite Division of the International Bureau. Specifically, Bureau staff asked DISH
to report on any gaseous helium (“GHe”) that will remain in the oxidizer tanks of the EchoStar 7
satellite at its end-of-life (“EOL”). Based on the volume of oxidizer tank #1, and assuming the
remaining oxidizer mass is distributed approximately equally across both tanks based on historical
pressure/temperature data, DISH calculates that, at EOL, the mass of GHe in a single oxidizer tank will
be about 0.865 kg. Accordingly, the combined total mass of GHe distributed approximately equally
across both oxidizer tanks will be about 1.73 kg. This value takes into account the vapor pressure of
oxidizer at the historical pressure/temperature values.


Marlene H. Dortch
October 9, 2012
Page 2


         Bureau staff also asked DISH to estimate the amount of GHe that will remain in each of the two
pressurant tanks at EchoStar 7’s EOL. DISH’s best estimate is that approximately ½ of the reported
total remaining mass of GHe (as set forth in DISH’s letter of September 28, 2012) will remain in each
pressurant tank at EOL.

       DISH asks that the chart submitted in its September 28, 2012 letter be considered updated with
the above information.

       Please contact the undersigned should you have any questions with respect to the information
submitted in this letter.



                                                   Respectfully submitted,

                                                              /s/

                                                   Stephanie A. Roy
                                                   Counsel for DISH Operating L.L.C.

Cc:    Karl Kensinger
       Chip Fleming



Document Created: 2012-10-09 16:14:26
Document Modified: 2012-10-09 16:14:26