Test reports

FCC ID:

Test Report

Download: PDF

                             Global United Technology Services Co., Ltd.
                                                                                  Report No.: GTS201908000149F01


                               Test Report (Bluetooth)
 Applicant:                            Orange View Limited
                                       Suite 603,6/F,Laws Commerical Plaza,788 Cheung Sha Wan
 Address of Applicant:
                                       Road,Kowloon, Hong Kong
 Manufacturer/Factory:                 Orange View Limited
 Address of                            Suite 603,6/F,Laws Commerical Plaza,788 Cheung Sha Wan
 Manufacturer/Factory:                 Road,Kowloon, Hong Kong
 Equipment Under Test (EUT)
   Product Name:                       Aicool Smart Trash Can

   Model No.:                          Hero

   Trade Mark:                         AICOOL

 FCC ID:                               2AUD5-Hero

 Applicable standards:                 FCC CFR Title 47 Part 15 Subpart C Section 15.247

 Date of sample receipt:               Aug 15,2019

 Date of Test:                         Aug 15,2019-Aug 23,2019

 Date of report issued:                Aug 23,2019

 Test Result :                         PASS *
* In the configuration tested, the EUT complied with the standards specified above.




Authorized Signature:




   Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.
                                                                                                              Page 1 of 32


                                                                               Report No.: GTS201908000149F01

2      Version
            Version No.                                Date                              Description
                00                                  Aug 23,2019                            Original




Prepared By:                                                       Date:                 Aug 23,2019

                                     Project Engineer



Check By:                                                          Date:                 Aug 23,2019

                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 2 of 32


                                                                                                              Report No.: GTS201908000149F01

3         Contents
                                                                                                                                                            Page
1       COVER PAGE ........................................................................................................................................... 1
2       VERSION .................................................................................................................................................. 2
3       CONTENTS .............................................................................................................................................. 3
4       TEST SUMMARY ..................................................................................................................................... 4
5       GENERAL INFORMATION ...................................................................................................................... 5
    5.1         GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2         TEST MODE ........................................................................................................................................ 7
    5.3         DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.4         TEST FACILITY.................................................................................................................................... 7
    5.5         TEST LOCATION ................................................................................................................................. 7
6       TEST INSTRUMENTS LIST ..................................................................................................................... 8
7       TEST RESULTS AND MEASUREMENT DATA.................................................................................... 10
    7.1     ANTENNA REQUIREMENT ................................................................................................................... 10
    7.2     CONDUCTED EMISSIONS ................................................................................................................... 11
    7.3     CONDUCTED OUTPUT POWER ........................................................................................................... 14
    7.4     CHANNEL BANDWIDTH ...................................................................................................................... 16
    7.5     POWER SPECTRAL DENSITY ............................................................................................................. 18
    7.6     BAND EDGES .................................................................................................................................... 20
       7.6.1 Conducted Emission Method ..................................................................................................... 20
       7.6.2 Radiated Emission Method ........................................................................................................ 21
    7.7     SPURIOUS EMISSION......................................................................................................................... 23
       7.7.1 Conducted Emission Method ..................................................................................................... 23
       7.7.2 Radiated Emission Method ........................................................................................................ 25
8       TEST SETUP PHOTO ............................................................................................................................ 32
9       EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 32




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                      Page 3 of 32


                                                                               Report No.: GTS201908000149F01

4      Test Summary
                 Test Item                             Section in CFR 47                         Result
          Antenna requirement                           15.203/15.247 (c)                         Pass
    AC Power Line Conducted Emission                          15.207                              Pass
        Conducted Output Power                             15.247 (b)(3)                          Pass
           Channel Bandwidth                               15.247 (a)(2)                          Pass
         Power Spectral Density                             15.247 (e)                            Pass
                Band Edge                                    15.247(d)                            Pass
           Spurious Emission                              15.205/15.209                           Pass
Remarks:
1. Pass: The EUT complies with the essential requirements in the standard.
2. Test according to ANSI C63.10:2013



Measurement Uncertainty
            Test Item                      Frequency Range                 Measurement Uncertainty         Notes
        Radiated Emission                    30MHz-200MHz                         3.8039dB                  (1)
        Radiated Emission                     200MHz-1GHz                         3.9679dB                  (1)
        Radiated Emission                     1GHz-18GHz                           4.29dB                   (1)
        Radiated Emission                     18GHz-40GHz                          3.30dB                   (1)
    AC Power Line Conducted
                                            0.15MHz ~ 30MHz                        3.44dB                   (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 4 of 32


                                                                               Report No.: GTS201908000149F01

5      General Information
5.1 General Description of EUT
      Product Name:                      Aicool Smart Trash Can
      Model No.:                         Hero
      Test sample(s) ID:                 GTS201908000149-1
      Sample(s) Status:                  Engineering sample
      Serial No.:                        N/A
      Hardware Version:                  N/A
      Software Version:                  SmartRF Studio7 1,0,3,0
      Operation Frequency:               2402~2480MHz
      Channel Numbers:                   40
      Channel Separation:                2MHz
      Modulation Type:                   GFSK
      Antenna Type:                      PCB antenna
      Antenna Gain:                      -3dBi
      Power Supply:                      Adapter information:input100-240V~50/60Hz 0.65A Max
                                         Output:18V/2A




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 5 of 32


                                                                                 Report No.: GTS201908000149F01

Operation Frequency each of channel
 Channel       Frequency        Channel       Frequency       Channel          Frequency   Channel        Frequency
     1          2402MHz            11         2422MHz            21            2442MHz       31           2462MHz
     2          2404MHz            12         2424MHz            22            2444MHz       32           2464MHz
   .
   ..…



                  .
                  ..…



                                 .
                                 ..…



                                                 .
                                                 ..…



                                                                .
                                                                ..…



                                                                                 .
                                                                                 ..…



                                                                                            .
                                                                                            ..…



                                                                                                            .
                                                                                                            ..…
     9          2418MHz            19         2438MHz            29            2458MHz       39           2478MHz
    10          2420MHz            20         2440MHz            30            2460MHz       40           2480MHz
Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
middle frequency, and the highest frequency of channel were selected to perform the test, and the selected
channel see below:

         Channel                        Frequency
   The lowest channel                   2402MHz
   The middle channel                   2440MHz
  The Highest channel                   2480MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 6 of 32


                                                                               Report No.: GTS201908000149F01

5.2 Test mode
       Transmitting mode            Keep the EUT in continuously transmitting mode
       Remark: During the test, the test voltage was tuned from 85% to 115% of the nominal rated supply
       voltage, and found that the worst case was under the nominal rated supply condition. So the report just
       shows that condition’s data.
5.3 Description of Support Units
       Adapter information:input100-240V~50/60Hz 0.65A Max Output:18V/2A

5.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC —Registration No.: 381383
       Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in files. Registration 381383.
       ● NVLAP (LAB CODE:600179-0)
       Global United Technology Services Co., Ltd., is accredited by the National Voluntary Laboratory
       Accreditation Program (NVLAP). LAB CODE:600179-0
5.5 Test Location
       All tests were performed at:
       Global United Technology Services Co., Ltd.
       Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
       Baoan District, Shenzhen, Guangdong, China 518102
       Tel: 0755-27798480
       Fax: 0755-27798960




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 7 of 32


                                                                               Report No.: GTS201908000149F01

6       Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date       Cal.Due date
Item       Test Equipment          Manufacturer              Model No.
                                                                                  No.       (mm-dd-yy)      (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron      9.2(L)*6.2(W)* 6.4(H)   GTS250      July. 03 2015    July. 02 2020
             Chamber
 2         Control Room          ZhongYu Electron      6.2(L)*2.5(W)* 2.4(H)   GTS251           N/A              N/A
 3       EMI Test Receiver       Rohde & Schwarz              ESU26            GTS203      June. 26 2019    June. 25 2020
                                 SCHWARZBECK
 4       BiConiLog Antenna                                  VULB9163           GTS214      June. 26 2019    June. 25 2020
                                MESS-ELEKTRONIK
          Double -ridged         SCHWARZBECK
 5                                                        BBHA 9120 D          GTS208      June. 26 2019    June. 25 2020
          waveguide horn        MESS-ELEKTRONIK
6          Horn Antenna          ETS-LINDGREN                 3160             GTS217      June. 26 2019    June. 25 2020
7        EMI Test Software           AUDIX                     E3               N/A             N/A              N/A
8          Coaxial Cable              GTS                     N/A              GTS213      June. 26 2019    June. 25 2020
9          Coaxial Cable              GTS                     N/A              GTS211      June. 26 2019    June. 25 2020
10          Coaxial cable             GTS                     N/A              GTS210      June. 26 2019    June. 25 2020
11         Coaxial Cable              GTS                     N/A              GTS212      June. 26 2019    June. 25 2020
12     Amplifier(100kHz-3GHz)          HP                    8347A             GTS204      June. 26 2019    June. 25 2020
13     Amplifier(2GHz-20GHz)           HP                   84722A             GTS206      June. 26 2019    June. 25 2020
                                                          AFS33-18002
14      Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      June. 26 2019    June. 25 2020
                                                          650-30-8P-44
15           Band filter             Amindeon                 82346            GTS219      June. 26 2019    June. 25 2020
16         Power Meter                Anritsu               ML2495A            GTS540      June. 26 2019    June. 25 2020
17        Power Sensor                Anritsu               MA2411B            GTS541      June. 26 2019    June. 25 2020
         Wideband Radio
18                               Rohde & Schwarz             CMW500            GTS575      June. 26 2019    June. 25 2020
       Communication Tester
19            Splitter                 Agilent               11636B            GTS237      June. 26 2019    June. 25 2020
20        Loop Antenna                ZHINAN                ZN30900A           GTS534      June. 26 2019    June. 25 2020
            Breitband
21                               SCHWARZBECK               BBHA 9170           GTS579      Oct. 20 2018     Oct. 19 2019
           hornantenne
22           Amplifier                 TDK                  PA-02-02           GTS574      Oct. 20 2018     Oct. 19 2019
23           Amplifier                 TDK                  PA-02-03           GTS576      Oct. 20 2018     Oct. 19 2019
       PSA Series Spectrum
24                               Rohde & Schwarz               FSP             GTS578      June. 26 2019    June. 25 2020
             Analyzer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 8 of 32


                                                                                  Report No.: GTS201908000149F01

Conducted Emission
                                                                                  Inventory    Cal.Date    Cal.Due date
Item         Test Equipment            Manufacturer            Model No.
                                                                                     No.      (mm-dd-yy)    (mm-dd-yy)
  1         Shielding Room          ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)      GTS252     May.15 2019 May.14 2022
  2        EMI Test Receiver              R&S                  ESCI 7             GTS552    June. 26 2019 June. 25 2020
  3         Coaxial Switch          ANRITSU CORP               MP59B              GTS225    June. 26 2019 June. 25 2020
                                    SCHWARZBECK
  4      Artificial Mains Network                              NSLK8127           GTS226      June. 26 2019 June. 25 2020
                                         MESS
  5         Coaxial Cable                 GTS                    N/A              GTS227           N/A           N/A
  6        EMI Test Software             AUDIX                   E3                N/A             N/A           N/A
  7         Thermo meter                  KTJ                   TA328             GTS233      June. 26 2019 June. 25 2020
                                       Elektronik-
  8         Absorbing clamp                                     MDS21             GTS229      June. 26 2019 June. 25 2020
                                     Feinmechanik
  9                ISN              SCHWARZBECK                NTFM 8158          GTD565      June. 26 2019 June. 25 2020


 RF Conducted Test:

                                                                                            Cal.Date          Cal.Due date
 Item       Test Equipment          Manufacturer        Model No.          Serial No.
                                                                                           (mm-dd-yy)         (mm-dd-yy)

  1      MXA Signal Analyzer          Agilent           N9020A               GTS566     June. 26 2019     June. 25 2020

  2       EMI Test Receiver            R&S              ESCI 7               GTS552     June. 26 2019     June. 25 2020

  3       Spectrum Analyzer           Agilent           E4440A               GTS533     June. 26 2019     June. 25 2020

          MXG vector Signal
  4                                   Agilent           N5182A               GTS567     June. 26 2019     June. 25 2020
             Generator
          ESG Analog Signal
  5                                   Agilent           E4428C               GTS568     June. 26 2019     June. 25 2020
             Generator

  6     USB RF Power Sensor           DARE             RPR3006W              GTS569     June. 26 2019     June. 25 2020


  7         RF Switch Box            Shongyi          RFSW3003328            GTS571     June. 26 2019     June. 25 2020

        Programmable Constant
  8       Temp & Humi Test           WEWON         WHTH-150L-40-880          GTS572     June. 26 2019     June. 25 2020
              Chamber



 General used equipment:
                                                                                  Inventory      Cal.Date        Cal.Due date
Item             Test Equipment                 Manufacturer        Model No.
                                                                                     No.        (mm-dd-yy)        (mm-dd-yy)
 1       Humidity/ Temperature Indicator           KTJ               TA328        GTS243      June. 26 2019     June. 25 2020
 2                  Barometer                   ChangChun            DYM3         GTS255      June. 26 2019     June. 25 2020




 Global United Technology Services Co., Ltd.
 No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
 Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
 Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 9 of 32


                                                                               Report No.: GTS201908000149F01

7      Test results and Measurement Data
7.1 Antenna requirement
       Standard requirement:           FCC Part15 C Section 15.203 /247(c)
       15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
       responsible party shall be used with the device. The use of a permanently attached antenna or of an
       antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
       so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
       electrical connector is prohibited.
       15.247(c) (1)(i) requirement:
       (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
       operations may employ transmitting antennas with directional gain greater than 6dBi provided the
       maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
       directional gain of the antenna exceeds 6dBi.
       E.U.T Antenna:
       The antenna is PIFA antenna, the best case gain of the antenna is -3dBi, reference to the appendix II
       for details.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 10 of 32


 GTS
                                                                                            Report No.: GTS201908000149F01
7.2     Conducted Emissions
      Test Requirement:                FCC Part15 C Section 15.207
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            150KHz to 30MHz
      Class / Severity:                Class B
      Receiver setup:                  RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                                          Limit (dBuV)
                                          Frequency range (MHz)                           Guasi—peak                  Average

                                                 0.15—0.5                   66 to 56*                                56 to 46"
                                                   0.5—5                       56                                       46
                                                   5—30                        60                                       50
                                       * Decreases with the logarithm of the frequency.
      Test setup:                                              Reference Plane
                                              LISN                                       LISN
                                                               40cm         80cm     —I

                                          aux                                             m           AC power
                                           Equipment              E.U.T
                                                                                   EMI
                                                                                   Receiver
                                              Test table/Insulation plane


                                       Remark
                                       EUT Eqvioment Under Test
                                       LISN Line Impedence Stabilzation Network
                                       Test table height=0 Bm

      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test environment:                Temp.:             25 °C             Humid.:             52%         Press.:        1012mbar
      Test voltage:                    AC 120V, 60Hz
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                              Page 11 of 32


                                                                               Report No.: GTS201908000149F01
Measurement data

 Mode:                    Bluetooth mode                                   Probe:          Line




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 12 of 32


                                                                               Report No.: GTS201908000149F01


 Mode:                    Bluetooth mode                                   Probe:          Neutral




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak
     emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
   both limits and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 13 of 32


                                                                               Report No.: GTS201908000149F01
7.3 Conducted Output Power
      Test Requirement:                FCC Part15 C Section 15.247 (b)(3)
      Test Method:                     ANSI C63.10:2013 and KDB558074 D01 DTS Meas Guidance V05r02
      Limit:                           30dBm
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass




Measurement Data
     Test channel            Peak Output Power (dBm)                 Limit(dBm)                Result
        Lowest                          -1.179
        Middle                          -1.472                         30.00                    Pass
        Highest                         -1.961




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 14 of 32


                                                                               Report No.: GTS201908000149F01
Test plot as follows:




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 15 of 32


                                                                                Report No.: GTS201908000149F01
7.4 Channel Bandwidth
      Test Requirement:                FCC Part15 C Section 15.247 (a)(2)
      Test Method:                     ANSI C63.10:2013 and KDB558074 D01 DTS Meas Guidance V05r02
      Limit:                           >500KHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement Data


     Test channel             Channel Bandwidth
                                                                   Limit(KHz)                   Result
                                   (MHz)
        Lowest                       0.6900
        Middle                       0.6609                           >500                       Pass
        Highest                      0.6739




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 16 of 32


                                                                               Report No.: GTS201908000149F01
Test plot as follows:




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 17 of 32


                                                                               Report No.: GTS201908000149F01
7.5 Power Spectral Density
      Test Requirement:                FCC Part15 C Section 15.247 (e)
      Test Method:                     ANSI C63.10:2013 and KDB558074 D01 DTS Meas Guidance V05r02
      Limit:                           8dBm/3kHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement Data


     Test channel           Power Spectral Density
                                                               Limit(dBm/3kHz)                 Result
                                (dBm/3kHz)
        Lowest                       -17.721
        Middle                       -19.075                          8.00                      Pass
        Highest                      -19.527




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 18 of 32


                                                                               Report No.: GTS201908000149F01
Test plot as follows:




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 19 of 32


                                                                               Report No.: GTS201908000149F01
7.6 Band edges
7.6.1 Conducted Emission Method
      Test Requirement:                FCC Part15 C Section 15.247 (d)
      Test Method:                     ANSI C63.10:2013 and KDB558074 D01 DTS Meas Guidance V05r02
      Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                       spread spectrum intentional radiator is operating, the radio frequency
                                       power that is produced by the intentional radiator shall be at least 20 dB
                                       below that in the 100 kHz bandwidth within the band that contains the
                                       highest level of the desired power, based on either an RF conducted or a
                                       radiated measurement.
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Test plot as follows:




                      Lowest channel                                            Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 20 of 32


                                                                               Report No.: GTS201908000149F01

7.6.2 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209 and 15.205
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            All of the restrict bands were tested, only the worst band’s (2310MHz to
                                       2500MHz) data was showed.
      Test site:                       Measurement Distance: 3m
      Receiver setup:                     Frequency         Detector       RBW        VBW           Value
                                                              Peak        1MHz        3MHz           Peak
                                        Above 1GHz
                                                              RMS         1MHz        3MHz         Average
      Limit:                                     Frequency             Limit (dBuV/m @3m)           Value
                                                                               54.00               Average
                                                Above 1GHz
                                                                               74.00                 Peak
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass

Measurement Data
Test channel:                                                Lowest
Peak value:
                 Read       Antenna        Cable      Preamp                                  Over
Frequency                                                            Level     Limit Line
                 Level       Factor        Loss        Factor                                 Limit     Polarization
  (MHz)                                                            (dBuV/m)    (dBuV/m)
                (dBuV)       (dB/m)        (dB)         (dB)                                  (dB)
 2390.00         41.29        27.59        5.38        30.18         44.08      74.00        -29.92         Horizontal
 2400.00         57.86        27.58        5.39        30.18         60.65      74.00        -13.35         Horizontal
 2390.00         41.69        27.59        5.38        30.18         44.48      74.00        -29.52          Vertical
 2400.00         59.72        27.58        5.39        30.18         62.51      74.00        -11.49          Vertical
Average value:
              Read          Antenna        Cable      Preamp                                  Over
Frequency                                                            Level     Limit Line
              Level          Factor        Loss        Factor                                 Limit     Polarization
  (MHz)                                                            (dBuV/m)    (dBuV/m)
             (dBuV)          (dB/m)        (dB)         (dB)                                   (dB)
 2390.00      32.20           27.59        5.38        30.18         34.99      54.00        -19.01         Horizontal
 2400.00      43.35           27.58        5.39        30.18         46.14      54.00         -7.87         Horizontal
 2390.00      32.03           27.59        5.38        30.18         34.82      54.00        -19.18          Vertical
 2400.00      44.84           27.58        5.39        30.18         47.63      54.00         -6.37          Vertical


Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 21 of 32


                                                                               Report No.: GTS201908000149F01
Test channel:                                                Highest
Peak value:
                 Read       Antenna        Cable      Preamp                                  Over
Frequency                                                            Level     Limit Line
                 Level       Factor        Loss        Factor                                 Limit     Polarization
  (MHz)                                                            (dBuV/m)    (dBuV/m)
                (dBuV)       (dB/m)        (dB)         (dB)                                  (dB)
 2483.50         43.21        27.53        5.47        29.93  46.28        74.00             -27.72
                                                                                                  Horizontal
 2500.00         42.68        27.55        5.49        29.93  45.79        74.00             -28.21
                                                                                                  Horizontal
 2483.50         43.79        27.53        5.47        29.93  46.86        74.00             -27.14Vertical
 2500.00         43.53        27.55        5.49        29.93  46.64        74.00             -27.36Vertical
Average value:
              Read       Antenna      Cable     Preamp                                Over
Frequency                                                     Level      Limit Line
              Level       Factor      Loss       Factor                               Limit      Polarization
  (MHz)                                                     (dBuV/m) (dBuV/m)
             (dBuV)       (dB/m)      (dB)        (dB)                                (dB)
 2483.50      35.01        27.53      5.47       29.93        38.08        54.00     -15.92       Horizontal
 2500.00      33.24        27.55      5.49       29.93        36.35        54.00     -17.65       Horizontal
 2483.50      36.09        27.53      5.47       29.93        39.16        54.00     -14.84        Vertical
 2500.00      33.03        27.55      5.49       29.93        36.14        54.00     -17.86        Vertical
Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. The pre-test were performed on lowest, middle and highest frequencies, only the worst case’s (lowest
    and highest frequencies) data was showed.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 22 of 32


                                                                               Report No.: GTS201908000149F01
7.7 Spurious Emission
7.7.1 Conducted Emission Method
      Test Requirement:                FCC Part15 C Section 15.247 (d)
      Test Method:                     ANSI C63.10:2013 and KDB558074 D01 DTS Meas Guidance V05r02
      Limit:                           In any 100 kHz bandwidth outside the frequency band in which the
                                       spread spectrum intentional radiator is operating, the radio frequency
                                       power that is produced by the intentional radiator shall be at least 20 dB
                                       below that in the 100 kHz bandwidth within the band that contains the
                                       highest level of the desired power, based on either an RF conducted or a
                                       radiated measurement.
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 23 of 32


                                                                               Report No.: GTS201908000149F01
Test plot as follows:
Lowest channel




                                                   30MHz~25GHz
Middle channel




                                                   30MHz~25GHz
Highest channel




                                                   30MHz~25GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 24 of 32


                                                                                 Report No.: GTS201908000149F01

7.7.2 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            9kHz to 25GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                       Frequency            Detector         RBW        VBW             Value
                                          9KHz-150KHz          Quasi-peak         200Hz      600Hz      Quasi-peak
                                         150KHz-30MHz          Quasi-peak         9KHz       30KHz      Quasi-peak
                                          30MHz-1GHz           Quasi-peak        120KHz     300KHz      Quasi-peak
                                                                   Peak           1MHz       3MHz            Peak
                                           Above 1GHz
                                                                   Peak           1MHz       10Hz           Average
      Limit:                                                                                         Measurement
                                               Frequency             Limit (uV/m)         Value
                                                                                                      Distance
                                         0.009MHz-0.490MHz           2400/F(KHz)           QP               300m
                                         0.490MHz-1.705MHz          24000/F(KHz)           QP               30m
                                          1.705MHz-30MHz                    30             QP               30m
                                            30MHz-88MHz                   100              QP
                                           88MHz-216MHz                   150              QP
                                           216MHz-960MHz                  200              QP
                                                                                                            3m
                                            960MHz-1GHz                   500              QP
                                                                          500            Average
                                             Above 1GHz
                                                                          5000            Peak
      Test setup:                      For radiated emissions from 9kHz to 30MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 25 of 32


                                                                               Report No.: GTS201908000149F01
                                       For radiated emissions from 30MHz to1GHz




                                       For radiated emissions above 1GHz




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test environment:                Temp.:        25 C         Humid.:      52%        Press.:      1012mbar
      Test voltage:                    AC 120V, 60Hz
      Test results:                    Pass


Measurement data:

Remark:
Pre-scan all kind of the place mode (X-axis, Y-axis, Z-axis), and found the Y-axis which it is worse case.


   9kHz~30MHz

The low frequency, which started from 9 kHz to 30 MHz, was pre-scanned and the result which was 20 dB
lower than the limit line per 15.31(o) was not reported.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 26 of 32


                                                                                 Report No.: GTS201908000149F01

     Below 1GHz

    Mode:                 Bluetooth mode                                       Polarization:      Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 27 of 32


                                                                                 Report No.: GTS201908000149F01


 Mode:                    Bluetooth mode                                       Polarization:      Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 28 of 32


                                                                                      Report No.: GTS201908000149F01
      Above 1GHz
Test channel:                                                      Lowest
Peak value:
                     Read         Antenna        Cable       Preamp                                     Over
Frequency                                                                   Level      Limit Line
                     Level         Factor        Loss         Factor                                    Limit   polarization
  (MHz)                                                                   (dBuV/m)     (dBuV/m)
                    (dBuV)         (dB/m)        (dB)          (dB)                                     (dB)
     4804.00         36.35          31.78        8.60         32.09         44.64         74.00        -29.36        Vertical
     7206.00        31.20          36.15         11.65        32.00         47.00         74.00        -27.00        Vertical
     9608.00        30.91          37.95         14.14        31.62         51.38         74.00        -22.62        Vertical
 12010.00              *                                                                  74.00                      Vertical
 14412.00              *                                                                  74.00                      Vertical
     4804.00        40.45          31.78          8.60        32.09         48.74         74.00        -25.26       Horizontal
     7206.00        32.87          36.15         11.65        32.00         48.67         74.00        -25.33       Horizontal
     9608.00        30.24          37.95         14.14        31.62         50.71         74.00        -23.29       Horizontal
 12010.00              *                                                                  74.00                     Horizontal
 14412.00       *                                                                         74.00                     Horizontal
Average value:
              Read               Antenna         Cable       Preamp                                     Over
Frequency                                                                   Level      Limit Line
              Level               Factor         Loss        Factor                                     Limit   polarization
   (MHz)                                                                  (dBuV/m)     (dBuV/m)
             (dBuV)               (dB/m)         (dB)          (dB)                                     (dB)
  4804.00     25.35                31.78         8.60         32.09         33.64        54.00         -20.36        Vertical
     7206.00        19.99          36.15         11.65        32.00         35.79        54.00         -18.21        Vertical
     9608.00        19.13          37.95         14.14        31.62         39.60        54.00         -14.40        Vertical
 12010.00              *                                                                 54.00                       Vertical
 14412.00              *                                                                 54.00                       Vertical
     4804.00        29.47          31.78         8.60         32.09         37.76        54.00         -16.24       Horizontal
     7206.00        22.10          36.15         11.65        32.00         37.90        54.00         -16.10       Horizontal
     9608.00        18.78          37.95         14.14        31.62         39.25        54.00         -14.75       Horizontal
 12010.00              *                                                                 54.00                      Horizontal
 14412.00              *                                                                 54.00                      Horizontal
Remarks:
1.     Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.     “*”, means this data is the too weak instrument of signal is unable to test.
3.     The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 29 of 32


                                                                                    Report No.: GTS201908000149F01

Test channel:                                                    Middle
Peak value:
                  Read         Antenna         Cable       Preamp                                     Over
Frequency                                                                 Level      Limit Line
                  Level         Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                 (dBuV/m)     (dBuV/m)
                 (dBuV)         (dB/m)         (dB)          (dB)                                     (dB)
 4884.00          36.96          31.85         8.67         32.12         45.36        74.00         -28.64        Vertical
 7326.00          31.60          36.37         11.72        31.89         47.80        74.00         -26.20        Vertical
 9768.00          31.27          38.35         14.25        31.62         52.25        74.00         -21.75        Vertical
 12210.00            *                                                                 74.00                       Vertical
 14652.00            *                                                                 74.00                       Vertical
 4884.00          41.18          31.85         8.67         32.12         49.58        74.00         -24.42       Horizontal
 7326.00          33.33          36.37         11.72        31.89         49.53        74.00         -24.47       Horizontal
 9768.00          30.66          38.35         14.25        31.62         51.64        74.00         -22.36       Horizontal
 12210.00            *                                                                 54.00                      Horizontal
 14652.00       *                                                                      54.00                      Horizontal
Average value:
              Read             Antenna         Cable       Preamp                                     Over
Frequency                                                                 Level      Limit Line
              Level             Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                 (dBuV/m)     (dBuV/m)
             (dBuV)             (dB/m)         (dB)          (dB)                                     (dB)
 4884.00      25.85              31.85         8.67         32.12         34.25        54.00         -19.75        Vertical
 7326.00          20.33          36.37         11.72        31.89         36.53        54.00         -17.47        Vertical
 9768.00          19.43          38.35         14.25        31.62         40.41        54.00         -13.59        Vertical
 12210.00            *                                                                 54.00                       Vertical
 14652.00            *                                                                 54.00                       Vertical
 4884.00          30.04          31.85         8.67         32.12         38.44        54.00         -15.56       Horizontal
 7326.00          22.49          36.37         11.72        31.89         38.69        54.00         -15.31       Horizontal
 9768.00          19.13          38.35         14.25        31.62         40.11        54.00         -13.89       Horizontal
 12210.00            *                                                                 54.00                      Horizontal
 14652.00            *                                                                 54.00                      Horizontal
Remarks:
1.   Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   “*”, means this data is the too weak instrument of signal is unable to test.
3.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 30 of 32


                                                                                    Report No.: GTS201908000149F01

Test channel:                                                    Highest
Peak value:
                  Read         Antenna         Cable       Preamp                                     Over
Frequency                                                                 Level      Limit Line
                  Level         Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                 (dBuV/m)     (dBuV/m)
                 (dBuV)         (dB/m)         (dB)          (dB)                                     (dB)
 4960.00          37.16          31.93         8.73         32.16          45.66       74.00         -28.34        Vertical
 7440.00          31.73          36.59         11.79        31.78          48.33       74.00         -25.67        Vertical
 9920.00          31.38          38.81         14.38        31.88          52.69       74.00         -21.31        Vertical
 12400.00            *                                                                 74.00                       Vertical
 14880.00            *                                                                 74.00                       Vertical
 4960.00          41.41          31.93         8.73         32.16          49.91       74.00         -24.09       Horizontal
 7440.00          33.47          36.59         11.79        31.78          50.07       74.00         -23.93       Horizontal
 9920.00          30.79          38.81         14.38        31.88          52.10       74.00         -21.90       Horizontal
 12400.00            *                                                                 74.00                      Horizontal
 14880.00       *                                                                      74.00                      Horizontal
Average value:
              Read             Antenna         Cable       Preamp                                     Over
Frequency                                                                 Level      Limit Line
              Level             Factor         Loss        Factor                                     Limit   polarization
  (MHz)                                                                 (dBuV/m)     (dBuV/m)
             (dBuV)             (dB/m)         (dB)          (dB)                                     (dB)
 4960.00      26.08              31.93         8.73         32.16          34.58       54.00         -19.42        Vertical
 7440.00          20.49          36.59         11.79        31.78          37.09       54.00         -16.91        Vertical
 9920.00          19.57          38.81         14.38        31.88          40.88       54.00         -13.12        Vertical
 12400.00            *                                                                 54.00                       Vertical
 14880.00            *                                                                 54.00                       Vertical
 4960.00          30.30          31.93         8.73         32.16          38.80       54.00         -15.20       Horizontal
 7440.00          22.66          36.59         11.79        31.78          39.26       54.00         -14.74       Horizontal
 9920.00          19.30          38.81         14.38        31.88          40.61       54.00         -13.39       Horizontal
 12400.00            *                                                                 54.00                      Horizontal
 14880.00            *                                                                 54.00                      Horizontal
Remarks:
1.   Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2.   “*”, means this data is the too weak instrument of signal is unable to test.
3.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 31 of 32


                                                                               Report No.: GTS201908000149F01
8      Test Setup Photo
      Reference to the appendix I for details.

9      EUT Constructional Details
      Reference to the appendix II for details.

                                                    ------End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 32 of 32



Document Created: 2019-09-11 04:21:03
Document Modified: 2019-09-11 04:21:03

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC