  Operation Manual
               RF Deactivator

                 DAV 200


The Deactivator DAV-200 deactivates any standard 8.2MHz deactivatable Labels. The
Deactivator sends short bursts of approximate 10 μs. After this period the transmitter is
switched off and the receiver becomes active. If a non- deactivated Label or Tag is near the
deactivator antenna plate an ECHO signal is received and an audible internal Buzzer alarm
is given (Option: external Buzzer).
The electronic unit is line-synchronized via the power supply PSD-300.




DAV 200 2018-11                                  Page 2


                      X3    X2           X1




        

        

        

         




         To DAV 300              To DAV 300




DAV 200 2018-11            Page 3


"LUucaATRON®                                                 powered by


   Installation Rules


   Distances

   Observe a minimum of 50¢em away from Antenna Pad to:

         — Electronic Devices:

                — Credit card Readers

                — Cash Registers

                — Computer Systems

                — All electronic Devices

   All the above devices could lead to malfunctions.



  A minimum distance from Antenna Pad to metal parts:

   — Side of antenna 4 em

   — Under the antenna 3 em



   Caution:     The deactivation height is reduced with metal parts near the
                Antenna Pad.


                               




     -




              DAV 200                          X3


         X2

         X1
                                                    Cable 2 x 0.75
                                                    mm2
                                                    < 1 meter


                                                    .



                 PSD 300




                    Optional External Buzzer




    To DAV 300




DAV 200 2018-11                                            Page 5


"LUucaATRON®                                         omiraro |

   Pad (DAP 300) Mounting

   a.) On top of counter




   b.) Insert into counter top




   c.) Below the counter top




           SCREW     E                  ‘          =
                                                   SCHEW
                 BRACKET         DEACTIVATOR PAD




                 Please ensure that the cutting is
                 not bigger than specified


              PSD 300

                   SYNC
                  12VDC
                    GND
                   SYNC




       

       


DAV 200 2018-11           Page 7


            DAV 200
      X2                                      X3

      X1

                                              Cable 2 x 0.75 mm2
                                              < 1 meter

                                                                   Copper wire 1-1.5 mm2
                                              .                    30cm x 30cm



                 PSD 300                                           .



                   Signal from Scanner (Contact)
                                                    Pin 1  Signal
                                                    Pin 4  GND
                                                    Contact open deactivation enabled
                                                    Contact closed  deactivation disabled

    To DAV 300
                   Optional External Buzzer




    To DAV 300




DAV 200 2018-11                                          Page 8


Jumper setting:
     J1 Factory setting (default is OUT)

      J2, J3 & J4, J5 Matching of deactivation coil (for our standard pad
                        DAP 300 no setting is required)

      J6  Factory setting (default is OUT)

      J7 Power line synchronization active (default IN)

      J8  Factory setting (default is OUT)

      J9 internal Buzzer (IN – Buzzer ON (default), OUT – Buzzer OFF)




DAV 200 2018-11                               Page 9


                  8.2




DAV 200 2018-11         Page 10


This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more of
the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which
the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.

Caution: Any changes or modifications to this device not explicitly approved
by manufacturer could void your authority to operate this equipment.

This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference,
and (2) this device must accept any interference received, including
interference that may cause undesired operation.

This equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment.
This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.