MPE Report

FCC ID: 2ASKIMD6972

RF Exposure Info

Download: PDF

                          Test Report No.: HP190411KF01-FMP




                                                       RF Exposure report
                    Report No.: HP190411KF01-FMP

                          FCC ID: 2ASKIMD6972

               Product Name CD BOOMBOX with Bluetooth® Wireless Technology

                    Test Model: MD6972

               Received Date: 2019-4-11

                       Test Date: 2019-4-11~2019-4-29

                   Issued Date: 2019-5-7

            Applicant Name: ANKANG COMATE TECH CO., LTD

        Applicant Address: North end of Gaoxin No.7 Road, The High-Tech Industrial Zone,
                           Ankang Shaanxi, China

                      Issued By: Hwa-Hsing (Dongguan) Testing Co., Ltd.

                 Lab Address: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang
                              Town, Dongguan, China

                Test Location: No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial Park, HuangJiang
                               Town, Dongguan, China

            FCC Designation
                   Number: CN1255
                                        FCC Part 2 (Section 2.1091)
                     Standards:
                                        KDB 447498 D01
                                        IEEE C95.1

The above equipment has been tested by Hwa-Hsing (Dongguan) Testing Co., Ltd., and found compliance with
the requirement of the above standards. The test record, data evaluation & Equipment Under Test (EUT)
configurations represented herein are true and accurate accounts of the measurements of the sample’s EMC
characteristics under the conditions specified in this report.



       Prepared by :                                                                        Date:               May 05, 2019
                                             Tank Tan//Engineer




     Approved by :                                                                          Date:               May 07, 2019
                                            Harry Li/ Supervisor
This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set
forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical
product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that
you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided,
however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless
specific mention, the uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the
specification.The report must not be used by the client to claim product certification, approval, or endorsement by A2LA or any agency of the federal
government.The report must not be used by the client to claim product certification, approval, or endorsement by TAF or any government agencies.

                                                                                                        Tel: 0769-83078199
  Hwa-Hsing (Dongguan) Testing             No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                                        Web.: www.hwa-hsing.com
  Co., Ltd.                                Park, HuangJiang Town, Dongguan, China
                                                                                                        E-Mail: customerservice.dg@hwa-hsing.com
                                                                 Page 1 of 4                                                 Report Version: V1.1.1


                    Test Report No.: HP190411KF01-FMP



                                               Table of contents

Release control record ............................................................................................... 3
2.    MPE calculation formula .................................................................................. 4
3.    Classification.................................................................................................... 4
4.    Calculation result of maximum conducted power............................................. 4




                                                                                 Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing    No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                 Web.: www.hwa-hsing.com
 Co., Ltd.                       Park, HuangJiang Town, Dongguan, China
                                                                                 E-Mail: customerservice.dg@hwa-hsing.com
                                                   Page 2 of 4                                    Report Version: V1.1.1


                  Test Report No.: HP190411KF01-FMP




                                          Release control record

Issue No.                      Reason for change                                                   Date issued
HP190411KF01-FMP               Original release                                                     May 07, 2019




                                                                                Tel: 0769-83078199
Hwa-Hsing (Dongguan) Testing    No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                Web.: www.hwa-hsing.com
Co., Ltd.                       Park, HuangJiang Town, Dongguan, China
                                                                                E-Mail: customerservice.dg@hwa-hsing.com
                                                  Page 3 of 4                                   Report Version: V1.1.1


                   Test Report No.: HP190411KF01-FMP



1. RF exposure limit

Limits for maximum permissible exposure (MPE)
                                 Limits for general population / uncontrolled exposure
  Frequency range        Electric field strength Magnetic field strength           Power density            Average time
         (MHz)                   (V/m)                   (A/m)                      (mW/cm2)                 (minutes)

      300-1500                       …                          …                     F/1500                      30
   1500-100,000                      …                          …                       1.0                       30

Note: F = Frequency in MHz


2. MPE calculation formula
Pd = (Pout*G) / (4*pi*r2)
Where:
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm



3. Calculation result of maximum conducted power
Classification: The antenna of this product, under normal use condition, is at least 20cm away from
the body of the user. So, this device is classified as Mobile Device.

The antennas provided to the EUT, please refer to the following table:
  Frequency Band                 Antenna Gain (dBi)                   Antenna Type

 2.4GHz Bluetooth                        -0.58                        PCB Antenna


  Frequency band          Max power          Antenna gain            Distance          Power density             Limit
      (MHz)                 (mW)                 (dBi)                 (cm)             (mW/cm2)               (mW/cm2)
 2400~2483.5MHz                 1.592             -0.58                  20               0.000298                 1.0

Conclusion:
Therefore, the worst-case situation is 0.000298 mW/cm2, which is less than “1”. This confirmed that
the device compliance with FCC 1.1310 MPE limit.




                                                                                    Tel: 0769-83078199
 Hwa-Hsing (Dongguan) Testing      No.101, Bld N1, Yuyuan 2Rd, Yuyuan Industrial
                                                                                    Web.: www.hwa-hsing.com
 Co., Ltd.                         Park, HuangJiang Town, Dongguan, China
                                                                                    E-Mail: customerservice.dg@hwa-hsing.com
                                                     Page 4 of 4                                    Report Version: V1.1.1



Document Created: 2019-05-13 09:10:56
Document Modified: 2019-05-13 09:10:56

© 2019 FCC.report