Verizon Wireless

0649-EX-ST-2017

Status: Grant Expired Due to New License

WK9XRG
2017-06-05

Documents and Communications: [refresh]

DescriptionCategoryDate
Grant E-mail Notification generated [Jun 5 2017]Correspondence2017-06-05
Grant E-mail Notification generated [Jun 5 2017]Correspondence2017-06-05
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Verizon Wireless

Address
Attention: Krishnamurthy Sreenath
Street Address: One Verizon Way
P.O. Box:
City: Basking Ridge
State: NJ
Zip Code: 07920
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Sreenath
First Name: Krishnamurthy
Title: PMTS
Phone Number: 908-559-1728

Explanation
Please explain in the area below why an STA is necessary:
An STA is required to conduct a market trial of new communications equipment during a short-term period of six months.

Purpose of Operation
Please explain the purpose of operation:  The purpose of the proposed operations is to conduct a market trial of new communications equipment pursuant to Sections 5.3(k) and 5.602 of the FCCs rules.

Information
Callsign: WK9XRG
Class of Station: FX MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 06/13/2017
Operation End Date: 12/13/2017

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Various NA 80 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Gregory M. Romano
Title of Applicant (if any): VP & Associate General Counsel, Verizon
Date: 2017-05-16 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
North  42  16  36 West  83  44  37 Ann Arbor, MI 5.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MG7W QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MK1W Amplitude

City State Latitude Longitude Mobile Radius of Operation
Ann Arbor Michigan North  42  16  36 West  83  44  37
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MG7W QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MK1W Amplitude

City State Latitude Longitude Mobile Radius of Operation
Ann Arbor Michigan North  42  17  1 West  83  44  16
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MG7W QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MK1W Amplitude

City State Latitude Longitude Mobile Radius of Operation
North  42  17  1 West  83  44  16 Ann Arbor, MI 5.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MG7W QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MK1W Amplitude

City State Latitude Longitude Mobile Radius of Operation
Ann Arbor Michigan North  42  16  27 West  83  44  9
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MG7W QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz FX 5.000000 W 630.950000 W P 800MK1W Amplitude

City State Latitude Longitude Mobile Radius of Operation
North  42  16  27 West  83  44  9 Ann Arbor, MI 5.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   10.00
(b) Orientation in horizontal plane:   360.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MG7N QPSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 16 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MW7W 64 QAM
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27.52500000-28.32500000 GHz MO 0.631000 W 19.950000 W P 800MK1W Amplitude

66669