The MITRE Corporation

0660-EX-ST-2016

Status: Grant Expired Due to New License

WH2XCI
2016-06-16

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [May 25 2016]Correspondence2016-05-25
Incoming generated [Jun 15 2016]Correspondence2016-06-15
Grant E-mail Notification generated [Jun 17 2016]Correspondence2016-06-17
Transmit Site location and Transmit Antenna Description and DrawingText Documents2016-05-02
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  The MITRE Corporation

Address
Attention: Lucien Teig
Street Address: 202 Burlington Road
P.O. Box:
City: Bedford
State: MA
Zip Code: 01730
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Scheible
First Name: Maureen
Title: Principle Investigator
Phone Number: 315-838-2662

Explanation
Please explain in the area below why an STA is necessary:
The MITRE Corporation seeks a Special Temporary Authority to transmit from two locations in Alaska from 20-24 June. USNORTHCOM is conducting a test between these two location and have asked the MITRE team conducting advanced beyond line of sight (BLOS) High Frequency (HF) communications to be part of the test. As such, we will need transmit authority for those 5 days in that location.

Purpose of Operation
Please explain the purpose of operation:  Test a series of over-the-air (OTA) MIMO. The MITRE Corporation is seeking an FCC Experimental License to transmit data from 20-24 June 2016 within the HF band between 6 MHz and 11 MHz. The test is planned to include a series of over-the-air (OTA) MIMO demonstrations, each testing new waveforms. We will attempt to test whether we can use both X and O modes to carry independent communications channels and then determine the carrying capability of each at different bandwidths. A stretch goal is to extend to wider bandwidth waveforms, up to 1 MHz. (Researchers’ note: we understand that this wideband waveform may run up against other users and possibly cause interference. We plan to transmit at as low a power as possible and on a not-to-interfere basis). We will also perform ionospheric sounding for channel characterization and to ensure we are operating on a not to interfere basis. Many of our waveforms will be small that 1 MHz bandwidth, but we request bandwidth up to that for experimentation purposes.

Information
Callsign: WH2XCI
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 06/20/2016
Operation End Date: 06/24/2016

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Ettus USRP N210 4 No
AR Modular RF KMA2040M22 4 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Maureen Scheible
Title of Applicant (if any): Portfolio Manager
Date: 2016-05-02 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Anchorage Alaska North  61  14  39 West  149  48  40 0.50
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   6.00
(b) Elevation of ground at antenna site above mean sea level in meters:   57.00
(c) Distance to nearest aircraft landing area in kilometers:   0.75
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: Antenna on top of building passed the Antenna Structure Registration TOWAIR Slope Test - does not need registration.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 100KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 100KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 100KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KW7D

City State Latitude Longitude Mobile Radius of Operation
Barrow Alaska North  71  17  27 West  156  46  54 0.10
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   6.00
(b) Elevation of ground at antenna site above mean sea level in meters:   3.00
(c) Distance to nearest aircraft landing area in kilometers:   0.60
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: Antenna passed the Antenna Structure Registration TOWAIR Slope Test - does not need registration. See Figure 1A for diagram of antenna in attached amendment.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.32000000-6.52500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 205KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.68500000-7.30000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 615KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.40000000-8.25000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 850KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.45000000-8.81500000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 365KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 8.96500000-9.40000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 435KW7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KD7D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KQ3N
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10.10000000-11.00000000 MHz FX 200.000000 W 200.000000 W P 0.00100000 % 900KW7D

78068