Toggle navigation
FCC.report
IBFS
ELS
FCC ID
Contact
About
FCC.report
›
ELS
›
T-Mobile USA, Inc.
›
1430-EX-ST-2017
T-Mobile USA, Inc.
1430-EX-ST-2017
Status: Grant Expired Due to New License
WL9XWZ
2017-10-23
Documents and Communications:
[
refresh
]
Description
Category
Date
Grant E-mail Notification generated [Oct 12 2017]
Correspondence
2017-10-12
Narrative
Text Documents
2017-10-03
Grant E-mail Notification generated [Oct 12 2017]
Correspondence
2017-10-12
Narrative
Text Documents
2017-10-03
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY
Applicant Name
Name of Applicant:
T-Mobile USA, Inc.
Address
Attention:
Chris Wieczorek
Street Address:
601 Pennsylvania Ave NW, N Bldg, Suite 800
P.O. Box:
20004
City:
Washington
State:
DC
Zip Code:
20004
Country:
E-Mail Address:
[email protected]
Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:
Last Name:
Dombrowsky
First Name:
Thomas
Title:
Senior Engineering Advisor
Phone Number:
2027994039
Explanation
Please explain in the area below why an STA is necessary:
T-Mobile USA, Inc. hereby respectfully requests experimental special temporary authority from November 12, 2017 to May 12, 2018. The experiments will operate in AWS-3 spectrum that is held by the Commission as well as utilizing 700 MHz, PCS, and AWS spectrum licensed to T-Mobile in the market. The testing will be in a highly controlled field environment that will help T-Mobile to allow the pre-commercial testing of new products outside of a lab environment but in a controlled and managed manner.
Purpose of Operation
Please explain the purpose of operation:
T-Mobile is working with equipment vendors to conduct product testing. The trials at the location listed below will allow T-Mobile to test prototype equipment in outdoor and indoor setting prior to equipment certification. The trials will consist of a base station that will use the transmission parameters detailed below in Section C. Mobile units will operate within three kilometers of the base station. T-Mobile anticipates using as many as 36 mobile units at the location.
Information
Callsign:
WL9XWZ
Class of Station:
FX MO
Nature of Service:
Experimental
Requested Period of Operation
Operation Start Date:
10/23/2017
Operation End Date:
04/23/2018
Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:
Manufacturer
Model Number
No. Of Units
Experimental
Ericsson
TA8AKRC161418-1
1
No
Ericsson
TA8AKRC16160-1
1
No
Ericsson
TA8AKRC161583-1
1
No
Experimental
Experimental
36
No
Nokia
VBNFRIJ-01
1
No
Samsung
A3LSMG950U
10
No
Samsung
A3LSMG955U
10
No
Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form):
Steve Sharkey
Title of Applicant (if any):
VP, Government Affairs Tech. & Engineering Policy
Date:
2017-09-27 00:00:00.0
Station Location
City
State
Latitude
Longitude
Mobile
Radius of Operation
El Paso
Texas
North 31 48 50
West 106 23 39
15.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
Yes
(a) Overall height above ground to tip of antenna in meters:
47.50
(b) Elevation of ground at antenna site above mean sea level in meters:
1193.20
(c) Distance to nearest aircraft landing area in kilometers:
0.72
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Existing tower (registration number 1013931). Experiment will not modify existing tower.
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
1755.00000000-1760.00000000 MHz
MO
250.000000 mW 500.000000 mW
P
0.00100000 %
5M00F7D
See attachment
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2155.00000000-2160.00000000 MHz
FX
1.000000 W 4.000000 W
P
0.00100000 %
5M00F7D
See attachment
City
State
Latitude
Longitude
Mobile
Radius of Operation
Augusta
Georgia
North 33 28 3
West 81 59 1
15.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
1765.00000000-1770.00000000 MHz
MO
250.000000 mW 500.000000 mW
P
0.00100000 %
5M00F7D
See attachment
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2165.00000000-2170.00000000 MHz
FX
1.000000 W 4.000000 W
P
0.00100000 %
5M00F7D
See attachment
City
State
Latitude
Longitude
Mobile
Radius of Operation
Augusta
Georgia
North 33 18 47
West 81 57 54
15.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
No
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
(b) Orientation in horizontal plane:
(c) Orientation in vertical plane:
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
1765.00000000-1770.00000000 MHz
MO
250.000000 mW 500.000000 mW
P
0.00100000 %
5M00F7D
See attachment
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
2165.00000000-2170.00000000 MHz
FX
1.000000 W 4.000000 W
P
0.00100000 %
5M00F7D
See attachment
31526