Rockwell Collins, Inc.

0116-EX-ST-2014

Status: Grant Expired Due to New License

WH9XHS
2014-03-25

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Feb 20 2014]Correspondence2014-02-20
E-Mail generated [Mar 6 2014]Correspondence2014-03-06
Grant E-mail Notification generated [Mar 26 2014]Correspondence2014-03-26
E-Mail generated [Feb 20 2014]Correspondence2014-02-20
E-Mail generated [Mar 6 2014]Correspondence2014-03-06
Grant E-mail Notification generated [Mar 26 2014]Correspondence2014-03-26
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Rockwell Collins, Inc.

Address
Attention: Laurie Sussman
Street Address: 1300 Wilson Blvd., Suite 200
P.O. Box:
City: Arlington
State: VA
Zip Code: 22209
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Sussman
First Name: Laurie
Title: Government Relations Manager
Phone Number: 703-516-8227

Explanation
Please explain in the area below why an STA is necessary:
Rockwell Collins will be participating in a Technical Experimentation (TE) event conducted by the United States Special Operations Command. This TE event will last three days only.

Purpose of Operation
Please explain the purpose of operation:  Technical Experimentation (TE) event conducted by the United States Special Operations Command. The United States Special Operations Command (USSOCOM) conducts Technical Experimentation (TE) events throughout the Continental United States with government, academic, and private industry representation. These events provide a unique opportunity for technology developers like Rockwell Collins to interact with the Special Operations Forces (SOF) community in a collaborative environment. In this test, TE 14-2, Rockwell Collins will test waveforms over the air to characterize performance and actual wideband HF (WBHF) channel propagation characteristics. In addition, it will test the feasibility of bridging WBHF with U.S. Tactical Digital Information Link (TADILJ), also known as Link-16 by its NATO designation. TE 14-2 offers a unique opportunity to test and evaluate the impacts, limitations, and utility of linking TADILJ/Link-16 with WBHF. This experimental communications capability is under development by Rockwell Collins and the Office of Naval Research and looks at alternative beyond-line-of-sight (BLOS) communications to meet SOF technical objectives of sustainment of operations in an anti-access, anti-denial environment.

Information
Callsign: WH9XHS
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 03/25/2014
Operation End Date: 04/03/2014

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Rockwell Collins RT-4800 1 Yes
Harris PRC-152A Hand-H 1 No
Harris PRC-117G Man Pa 1 No
Rockwell Collins TTR L-band 1 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Laurie Sussman
Title of Applicant (if any): Government Relations Manager
Date: 2014-02-10 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Fort Story Virginia North  36  55  32 West  76  2  38 Fort Story, VA
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 337.50000000- MHz FX 5.000000 W 5.000000 W P 1M20Q1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 1.000000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7674.00000000- kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9690.00000000-10285.00000000 kHz FX N/A 0.100000 kW P 237MQ1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10315.00000000-10755.00000000 kHz FX N/A 0.100000 kW P 237MQ1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10915.00000000-12060.00000000 kHz FX N/A 0.100000 kW P 237MQ1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 1.000000 kW P 48K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 1.000000 kW P 48K0J1D

43936

© 2024 FCC.report