Rockwell Collins, Inc.

0059-EX-ML-2011

Status: Grant Expired Due to New License

WF2XMP
2011-06-15

Filing Notes:

DescriptionDate
To define waveforms for high speed data over HF.2010-08-03

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Apr 21, 2011]Correspondence2011-04-21
Grant E-mail Notification generated [Jun 16 2011]Correspondence2011-06-16
Question 5 Amended FAA Antenna SketchImages2011-03-25
Application Form:
FCC FORM 442
FCC FORM 442 - FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR NEW OR MODIFIED RADIO STATION UNDER PART 5 OF FCC RULES - EXPERIMENTAL RADIO SERVICE (OTHER THAN BROADCAST)
Approved by OMB
3060 - 0065
Expires 09/30/98

Applicant's Name (company):  Rockwell Collins, Inc.        File No.:  0059-EX-ML-2011

Mailing Address
Attention: Laurie Bertenthal
Street Address: 1300 Wilson Blvd., Suite 200
P.O. Box:
City: Arlington
State: VA
Country:
Zip Code: 22209
E-Mail Address: lmberten@rockwellcollins.com

Application Purpose
Application is for:   MODIFICATION OF LICENSE

For Modification indicate below
File No.:   0335-EX-PL-2010  Callsign:   WF2XMP

Government Contract
Is this authorization to be used for fulfilling the requirement of a government contract with an agency of the United States Government?  If "YES", include as an exhibit a narrative statement describing the government project, agency and contract number.  No

Foreign Government Use
Is this authorization to be used for the exclusive purpose of developing radio equipment for export to be employed by stations under the jurisdiction of a foreign government?   If "YES", include the contract number and the name of the foreign government concerned as an exhibit.  No

Research Project
Is this authorization to be used for providing communications essential to a research project? (The radio communication is not the objective of the research project)?  If "YES", include as an exhibit the following information:
  1. A description of the nature of the research project being conducted.
  2. A showing that the communications facilities requested are necessary for the research project involved.
  3. A showing that existing communications facilities are inadequete.
  Yes

Exhibit Information
If all the answers to Items 4, 5, 6 are "NO", include as an exhibit a narrative statement describing in detail the following items:
  1. The complete program of research and experimentation proposed including description of equipment and theory of operation.
  2. The specific objectives sought to be accomplished.
  3. How the program of experimentation has a reasonable promise of contribution to the development, extension, expansion or utilization of the radio art, or is along line not already investigated.

Estimated Duration
Give an estimate of the length of time that will be required to complete the program of experimentation proposed in this application:   60   Months

Environmental Impact
Would a commission grant of this application come within Section 1.1307 of the FCC Rules, such that it may have a significant environmental impact?   If "YES", include as an exhibit an Environmental Assessment as required by Section 1.1311.   No

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit :  
Manufacturer Model Number No. Of Units Experimental
Rockwell Collins HF-80 8 Yes
Rockwell Collins Q9604 Modem 12 Yes
Rockwell Collins FlexNet-4 8 Yes
Rockwell Collins URG III PA 12 Yes

Station ID
Is the equipment listed in Item 10 capable of station identification pursuant to Section 5.115?   No

Applicant Type
Applicant is:  Corporation

Foreign Government
Is applicant a foreign government or a representative of a foreign government?   No

License Denied or Revoked
Has applicant or any party to this application had any FCC station license or permit revoked or any application for permit, license or renewal denied by this Commission?
If "YES", include as an exhibit a statement giving call sign of license or permit revoked and relate circumstances.
  No

Owner and Operator
Will applicant be owner and operator of the station?   Yes

Contact Information
Give the following information of person who can best handle inquiries pertaining to this application:   First Name: Laurie
Last Name: Bertenthal
Title: Government Regulatory Specialist
Phone Number: (703) 516-8227
E-Mail Address: lmberten@rockwellcollins.com

Drug Abuse Question
APPLICANT ANTI-DRUG ABUSE CERTIFICATION:   By checking "YES", the individual applicant certifies that he or she is eligible for this license. This requires that he or she is not subject to a denial of federal benefits, including FCC benefits, as a result of a drug offense conviction pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. 862. A non-individual applicant, e.g., corporation. partnership or other unincorporated association, certifies that no party to the application is subject to a denial of federal benefits, pursuant to that section. For definition of a "party" for these purposes, see 47CFR 1.2002(b).   Yes

Certification
THE APPLICANT CERTIFIES THAT:
  1. Copies of the FCC Rule Parts 2 and 5 are on hand; and
  2. Adequete financial appropriations have been made to carry on the program of experimentation which will be conducted by qualified personnel; and
  3. All operations will be on an experimental basis in accordance with Part 5 and other applicable rules, and will be conducted in such a manner and at such a time as to preclude harmful interference to any authorized station; and
  4. Grant of the authorization requested herein will not be construed as a finding on the part of the Commission:
    1. that the frequencies and other technical parameters specified in the authorization are the best suited for the proposed program of experimentation, and
    2. that the applicant will be authorized to operate on any basis other than experimental, and
    3. that the Comission is obligated by the results of the experimental program to make provision in its rules including its table of frequency allocations for applicant's type of operation on a regularly licensed basis.
THE APPLICANT FURTHER CERTIFIES THAT:
  1. All the statements in the application and attached exhibits are true, complete and correct to the best of the applicant's knowledge; and
  2. The applicant is willing to finance and conduct the experimental program with full knowledge and understanding of the above limitations; and
  3. The applicant waives any claim to the use of any particular frequency or of the electromagnetic spectrum as against the regulatory power of the USA.

Name of Applicant: Rockwell Collins, Inc.
Signature (Authorized person filing form): Laurie Bertenthal
Signature Date (Authorized person filing form): 03/25/2011
Title of Person Signing Application: Government Regulatory Specialist
Classification: Authorized employee
WILLFUL FALSE STATEMENTS MADE ON THIS FORM ARE PUNISHABLE BY FINE AND/OR IMPRISONMENT (U.S. CODE, TITLE 18, SECTION 1001), AND/OR REVOCATION OF ANY STATION LICENSE OR CONSTRUCTION PERMIT (U.S. CODE, TITLE 47, SECTION 312(A)(1)), AND/OR FORFEITURE (U.S. CODE, TITLE 47, SECTION 503).
NOTIFICATION TO INDIVIDUALS UNDER PRIVACY ACT OF 1974 AND THE PAPERWORK REDUCTION ACT OF 1980
Information requested through this form is authorized by the Communications Act of 1934, as amended, and specified by Section 308 therein. The information will be used by Federal Communications Commission staff to determine eligibility for issuing authorizations in the use of the frequency spectrum and to effect the provisions of regulatory responsibilities rendered by the Commission by the Act. Information requested by this form will be available to the public unless otherwise requested pursuant to 47 CFR 0.459 of the FCC Rules and Regulations. Your response is required to obtain this authorization.
Public reporting burden for this collection of information is estimated to average four (4) hours per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing the burden to the Federal Communications Commission, Records Management Branch, Paperwork Reduction Project (3060-0065), Washington DC 20554. DO NOT send completed applications to this address. Individuals are not required to respond to this collection unless it displays a currently valid OMD control number.
THE FOREGOING NOTICE IS REQUIRED BY THE PRIVACY ACT OF 1974, P.L. 93-579, DECEMBER 31, 1974, 5 U.S.C. 552a(e)(3), AND THE PAPERWORK REDUCTION ACT OF 1980, P.L. 96-511, DECEMBER 11, 1980, 44 U.S.C. 3507.

Station Location
City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Cedar Rapids Iowa North  42  0  38 West  91  38  45 855 35th Street N.E. LINN
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  Yes
(a) Width of beam in degrees at the half-power point:   60.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   33.00
(b) Elevation of ground at antenna site above mean sea level in meters:   183.00
(c) Distance to nearest aircraft landing area in kilometers:   22.50
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   There are trees in the vicinity of the antenna, but they are not as tall as the 100 foot antenna tower.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Oxford Junction Iowa North  41  57  41 West  90  53  37 1485 100th Ave., Building 189 CLINTON
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  No
(a) Width of beam in degrees at the half-power point:   60.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   33.00
(b) Elevation of ground at antenna site above mean sea level in meters:   183.00
(c) Distance to nearest aircraft landing area in kilometers:   72.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   There are trees in the vicinity of the antenna, but they are not as tall as the 100 foot antenna tower.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Richardson Texas North  32  59  43 West  96  39  37 3200 E. Renner Rd. COLLIN
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  No
(a) Width of beam in degrees at the half-power point:   80.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   33.00
(b) Elevation of ground at antenna site above mean sea level in meters:   159.00
(c) Distance to nearest aircraft landing area in kilometers:   16.30
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   There are trees in the vicinity of the antenna, but they are not as tall as the antenna tower, which has flashing safety lights installed at the tip of the antenna.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Las Cruces New Mexico North  32  16  44 West  106  45  14 1050 Stewart Street DONA ANA
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  No
(a) Width of beam in degrees at the half-power point:   65.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   29.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1194.00
(c) Distance to nearest aircraft landing area in kilometers:   15.60
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   There are trees in the vicinity of the antenna, but they are not as tall as the antenna tower, which has flashing safety lights installed at the tip of the antenna.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Benson Arizona North  32  27  29 West  110  9  8 Sibyl Road COCHISE
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  Yes
(a) Width of beam in degrees at the half-power point:   60.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   32.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1307.00
(c) Distance to nearest aircraft landing area in kilometers:   16.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   The antenna tower has a wide open view 360 degrees. The terrain is open flat to the nearest mountain 10 miles away due east, 90 degrees from 98 degrees to 360 it is relatively open flat terrain.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Benson Arizona North  32  27  29 West  110  9  8 Sibyl Road COCHISE
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  Yes
(a) Width of beam in degrees at the half-power point:   160.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   32.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1307.00
(c) Distance to nearest aircraft landing area in kilometers:   16.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   The antenna tower has a wide open view 360 degrees. The terrain is open flat to the nearest mountain 10 miles away due east, 90 degress from 98 degrees to 360 it is relatively open flat terrain.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

City State Latitude Longitude Mobile Street (or other indication of location) County Radius of Operation
0 Benson Arizona North  32  27  29 West  110  9  8 Sibyl Road COCHISE
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:  Yes
(a) Width of beam in degrees at the half-power point:   80.00
(b) Orientation in horizontal plane (degrees from True North):  360.00
(c) Orientation in vertical plane (degrees from horizontal): 
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   32.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1307.00
(c) Distance to nearest aircraft landing area in kilometers:   16.00
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:   The antenna tower has a wide open view 360 degrees. The terrain is open flat to the nearest mountain 10 miles away due east, 90 degress from 98 degrees to 360 it is relatively open flat terrain.
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2398.00000000-3171.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3260.00000000-4050.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4576.00000000-4611.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 4636.00000000-4950.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5100.00000000-5315.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5760.00000000-5960.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6060.00000000-6160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6770.00000000-6970.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7410.00000000-7483.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7650.00000000-7698.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7990.00000000-8060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9050.00000000-9350.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000-10400.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000-10800.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000-12090.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000-14550.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000-15860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000-16060.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000-17450.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000-18610.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000-20460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000-21860.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000-23160.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000-24460.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 25230.00000000-26490.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26910.00000000-27440.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 27990.00000000-29720.00000000 kHz FX N/A 25.000000 kW M 24K0J1D 19200 symbol rate

331342

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC