Panasonic Avionics Corporation

0079-EX-ST-2015

Status: Grant Expired Due to New License

WI9XHC
2015-02-23

Documents and Communications: [refresh]

DescriptionCategoryDate
Grant E-mail Notification generated [Feb 24 2015]Correspondence2015-02-24
Dismissal Without Prejudice generated [Jan 27 2015]Correspondence2015-01-27
Narrative StatementText Documents2015-01-23
AFTRCC Coordination ConcurrenceText Documents2015-02-11
FAA Non Governmental Trucking NumberText Documents2015-02-11
Letter Correcting Geographic CoordinatesText Documents2015-02-10
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Panasonic Avionics Corporation

Address
Attention: Mr. Mark DeFazio
Street Address: 26200 Enterprise Way
P.O. Box:
City: Lake Forest
State: CA
Zip Code: 92630
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Nalda
First Name: Carlos
Title: Counsel
Phone Number: 202-626-6659

Explanation
Please explain in the area below why an STA is necessary:
Panasonic Avionics Corporation (Panasonic) requests a 180-day experimental Special Temporary Authority (STA) commencing on or about February 6, 2015, to conduct ground testing in support of Panasonic’s Global Communications Suite (GCS) featuring the eXConnect Ku-band earth stations aboard aircraft (ESAA) system to provide broadband connectivity onboard aircraft in flight. It is requested that the experimental STA be granted to conduct the testing onboard parked aircraft the Sussex County Airport, Georgetown, DE. Panasonic is seeking to conduct electromagnetic interference ground testing of multiple, simulated transmit portable electronic devices (T-PEDs) onboard parked aircraft at the two airfields. Over the past few years, Panasonic has sought and obtained a series of separate, but related experimental STAs and two-year licenses to conduct T-PED EMI testing at multiple airfields. The instant application for an experimental STA is another in this series, seeking to add the Sussex County Airport, Georgetown, DE as a test site as requested by Panasonic’s airline customer.

Purpose of Operation
Please explain the purpose of operation:  T-ped testing It is the case that passengers are bringing onboard aircraft more and many types of personal communications devices (or transmit portable devices – T-PEDs), whether they be mobile phones and smartphones, Wi-Fi enabled laptop computers, tablets, etc. The use and proliferation of these devices of the traveling public is only expected to grow. It is therefore critical that the potential for interference to aircraft avionics, navigation and other systems from the onboard use of these devices be ascertained. The results of the proposed T-PED EMI tests will be used for the certification of Panasonic’s The purpose of the proposed testing is to conduct continued T-PED EMI testing onboard certain models of commercial aircraft at an additional airfield as requested by Panasonic’s airline customer: Sussex County Airport, Georgetown, DE.

Information
Callsign: WI9XHC
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 02/18/2015
Operation End Date: 08/05/2015

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
AeroMobile TBD 5 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Mark DeFazio
Title of Applicant (if any): Manager, GCS Regulatory and Business Operations
Date: 2015-01-23 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Georgetown Delaware North  38  41  27 West  75  21  21 Temporary fixed around parked aircraft 0.50
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 410.00000000-420.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 450.00000000-460.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 450.40000000-457.60000000 MHz MO 31.700000 W 29.500000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 479.00000000-484.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 614.00000000-698.00000000 MHz MO 31.700000 W 29.600000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 614.00000000-698.00000000 MHz MO 31.700000 W 29.600000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 776.00000000-794.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 806.00000000-849.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 824.00000000-849.00000000 MHz MO 31.700000 W 29.500000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 824.00000000-849.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 870.00000000-925.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 876.00000000-915.00000000 MHz MO 31.700000 W 29.500000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1427.90000000-1447.90000000 MHz MO 3.160000 W 1.060000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1427.90000000-1447.90000000 MHz MO 3.160000 W 1.060000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1447.90000000-1462.90000000 MHz MO 3.160000 W 1.060000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1447.90000000-1462.90000000 MHz MO 3.160000 W 1.060000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1613.80000000-1626.50000000 MHz MO 15.800000 W 13.700000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1626.50000000-1660.50000000 MHz MO 3.160000 W 1.060000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1626.50000000-1660.50000000 MHz MO 3.160000 W 1.060000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1710.00000000-1785.00000000 MHz MO 15.800000 W 13.700000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1710.00000000-1785.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1850.00000000-1910.00000000 MHz MO 15.800000 W 13.700000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1850.00000000-1910.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1900.00000000-1920.00000000 MHz MO 4.000000 W 1.800000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1920.00000000-1980.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2010.00000000-2025.00000000 MHz MO 4.000000 W 1.800000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2110.00000000-2170.00000000 MHz MO 4.000000 W 1.800000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2300.00000000-2400.00000000 MHz MO 3.160000 W 1.060000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2300.00000000-2400.00000000 MHz MO 3.160000 W 1.060000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2400.00000000-2497.00000000 MHz MO 5.000000 W 2.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2500.00000000-2685.00000000 MHz MO 15.800000 W 13.700000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2500.00000000-2685.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3400.00000000-3600.00000000 MHz MO 15.800000 W 13.700000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 3400.00000000-3600.00000000 MHz MO 15.800000 W 13.700000 W P 1M00N0N Continuous Wave
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5150.00000000-5250.00000000 MHz MO 5.000000 W 2.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5250.00000000-5350.00000000 MHz MO 5.000000 W 2.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5470.00000000-5725.00000000 MHz MO 5.000000 W 2.900000 W P 1M00P0N Pulse
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 5725.00000000-5825.00000000 MHz MO 5.000000 W 2.900000 W P 1M00P0N Pulse

72599