Northrop Grumman Systems Corporation

1477-EX-ST-2019

Status: Pending

N/A
2019-08-08

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Aug 8 2019]Correspondence2019-08-08
E-Mail generated [Aug 8 2019]Correspondence2019-08-08
ExhibitText Documents2019-08-08
Incoming generated [Aug 21 2019]Correspondence2019-08-21
Grant E-mail Notification generated [Aug 23 2019]Correspondence2019-08-23
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Northrop Grumman Systems Corporation

Address
Attention: DS LAW PLLC
Street Address: 1629 K St NW Ste 300
P.O. Box:
City: Washington
State: DC
Zip Code: 20006-1631
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Werle
First Name: Ron
Title: Manager, Flight Operations
Phone Number: 661-266-5024

Explanation
Please explain in the area below why an STA is necessary:
An STA is necessary to provide communications essential to a Non Contractual Technical Activity (NCTA) exercise to support the Navy Tactical Grid Exercise of 2019 to be held in September. Note: the MIDS LVT (RT1849)- Link 16 used in the 969-1206 MHz band uses notches centered on 1030 MHz and 1090 MHz to protect IFF and TCAS. See attachment.

Purpose of Operation
Please explain the purpose of operation:  The purpose of the operation is to support the Navy NCTA. The communications component being tested and demonstrated during the exercise will use standard CDL, Link-16 communications.

Information
Callsign: WP9XAS
Class of Station: FX MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 09/12/2019
Operation End Date: 02/28/2020

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
MIDS LVT RT1849 6 No
L3 CDL Mini T2 6 No
Rcokwell TTNT TTNT Phase 3 6 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Ron Werle
Title of Applicant (if any): Manager, Flight Operations
Date: 2019-08-08 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Patuxent River Maryland North  38  17  7 West  76  24  30 airborne maximum height 30,000 feet AGL 371.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz FX N/A 200.000000 W P 14M6G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz FX N/A 200.000000 W P 21M4G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz FX N/A 200.000000 W P 42M8G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz FX N/A 200.000000 W P 800KG1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz FX N/A 200.000000 W P 89M5G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz MO N/A 200.000000 W P 14M6G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz MO N/A 200.000000 W P 21M4G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz MO N/A 200.000000 W P 42M8G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz MO N/A 200.000000 W P 800KG1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 969.00000000-1206.00000000 MHz MO N/A 200.000000 W P 89M5G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz FX N/A 300.000000 W P 14M6G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz FX N/A 300.000000 W P 21M4G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz FX N/A 300.000000 W P 42M8G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz FX N/A 300.000000 W P 800KG1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz FX N/A 300.000000 W P 89M5G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz MO N/A 300.000000 W P 14M6G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz MO N/A 300.000000 W P 21M4G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz MO N/A 300.000000 W P 42M8G1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz MO N/A 300.000000 W P 800KG1D GMSK
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14415.00000000-14815.00000000 MHz MO N/A 300.000000 W P 89M5G1D GMSK

43893

© 2024 FCC.report