JAXON ENGINEERING and MAINTENANCE

1557-EX-ST-2020

Status: Pending

WQ9XRA
2020-10-07

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Oct 7 2020]Correspondence2020-10-07
E-Mail generated [Oct 7 2020]Correspondence2020-10-07
E-Mail generated [Oct 7 2020]Correspondence2020-10-07
E-Mail generated [Oct 9 2020]Correspondence2020-10-09
E-Mail generated [Oct 16 2020]Correspondence2020-10-16
Incoming generated [Oct 15 2020]Correspondence2020-10-15
Incoming generated [Oct 15 2020]Correspondence2020-10-15
Incoming generated [Oct 15 2020]Correspondence2020-10-15
Incoming generated [Oct 16 2020]Correspondence2020-10-16
Grant E-mail Notification generated [Oct 28 2020]Correspondence2020-10-28
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  JAXON ENGINEERING and MAINTENANCE

Address
Attention: Matt Day
Street Address: 8570 Criterion Drive, Suite 118
P.O. Box:
City: Colorado Springs
State: CO
Zip Code: 80920
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Hibbeler
First Name: Richard
Title: Manager
Phone Number: (703)726-5671

Explanation
Please explain in the area below why an STA is necessary:
To provide RF tests beginning November 5th, 2020 thru May 5th 2021. Testing will include 800 discrete frequencies evenly spaced between 100 kHz and 1 GHz. Each frequency will be a CW carrier, running for 30 mS. We can block out any interfering frequencies, as may be required by the FCC

Purpose of Operation
Please explain the purpose of operation:  RF testing in support of Defense Threat Reduction Agencys EMREP program. Jaxon Engineering is conducting tests for the DOD to determine RF integrity that houses sensitive electronic equipment that controls power grids.

Information
Callsign: WQ9XRA
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 11/05/2020
Operation End Date: 05/05/2021

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Agilent Network Analyzer E5071C 3 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Matt Day
Title of Applicant (if any): Authorized Representative
Date: 2020-10-07 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Corpus Christi Texas North  27  51  1 West  97  36  55
Datum:  NAD 83
Is a directional antenna (other than radar) used?   Yes
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:   60.00
(b) Orientation in horizontal plane:   180.00
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 0.10000000-5.90000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 6.20000000-7.20000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 7.45000000-9.40000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 9.90000000-11.60000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 12.10000000-13.57000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13.87000000-15.10000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15.80000000-17.48000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 17.90000000-18.90000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19.02000000-21.45000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 21.85000000-25.67000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 26.10000000-123.11250000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 123.58750000-225.00000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 328.60000000-335.00000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 399.90000000-758.00000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 768.00000000-788.00000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 798.00000000-1000.00000000 MHz FX N/A 39.811000 W M 0.00100000 % N0N CW