Narrative Statement for requirement 7

0267-EX-CN-2018 Text Documents

Itron

2018-04-04ELS_207515

Complete Program of Research and experimentation proposed
US3 makes a sewer overflow sensor designed to alert the City of Houston when sewer levels exceed an
acceptable threshold. The device will be installed in Combined Sewer Overflow (CSO) and Sanitary
Sewer Overflow (SSO) locations to monitor regulated flow conditions.
When the sewer level exceeds the acceptable threshold, the ultrasonic sensor detects this, and a voltage
output signal will be sent as an alarm, over the OpenWay Riva network, to the US3 application.

Description of equipment and theory of
operation
The waterproof enclose contains:
    •   Itron Riva DEV LE
    •   batteries to power device
    •   Batteries to power External Devices
    •   TTL Relay
    •   antenna
    •   connection to the ultrasonic sensor
    •   Connection to a Single point level
        sensor
Outside the orange enclosure, there is a
secondary float sensor that hangs at the alarm level in case the ultrasonic sensor fails to detect the
dangerous water level as it rises.

Specific objectives sought to be accomplished
Our objective in seeking an experimental license is to provide the customer with
early units while the radio in the device is modified to achieve Single-modular
transmitter certification.

How the program of experimentation has a reasonable promise of contribution to
the development, extension, expansion, or utilization of the radio art, or is along a
line not already investigated
Our program will enable the use of radio to improve timely detection of
conditions that could cause public health issues.



Document Created: 2018-04-03 12:54:04
Document Modified: 2018-04-03 12:54:04

© 2025 FCC.report