RADHAZ

1100-EX-ST-2017 Text Documents

Insitu

2017-08-03ELS_196167

Per CFR 47, section 1.1307.b(1), Table 1, all applications for
experimental operations with an ERP greater than 100 watts
require evaluation for compliance with human exposure
limits defined in section 1.1310, and if exceeded require
submission of an Environmental Assessment as defined in
section 1.1311.

The below calculations define the minimum safe working
distance for both Occupational and General Public, which are
based on the maximum permissible exposure limits of 5
mW/cm 2 and 1 mW/cm 2 respectively.

The antenna directional antenna operated in a controlled
area, and will be directed towards the aircraft in flight. Only
authorized occupational workers will be allowed access to
the area of operation. In addition the transmitter will be
secured prior to conducting maintenance, and the area will
be monitored during the operation to ensure that personnel
are clear of any radiation hazard area.




Transmitter Peak Power (Watts):      .7
Maximum Antenna Gain (dBi):          26.5
Duty Cycle (%):                      1
Transmitter Power (dBm):             28.451
EIRP (dBm):                          54.951
Non-dimensional Antenna Gain:        446.6836
Transmitter Avg Power (Watts):       0.007
EIRP Watts:                          312.6785
Avg EIRP Watts:                      3.1268

Minimum Safe Distance                        Occupational             General Public
Meters:

Feet:

                                     0.0705                       0.1577
                                     0.2314                       0.5175



Document Created: 2016-08-29 10:50:02
Document Modified: 2016-08-29 10:50:02