Per CFR 47, section 1.1307.b(1), Table 1, all applications for experimental operations
with an ERP greater than 100 watts require evaluation for compliance with human
exposure limits defined in section 1.1310, and if exceeded require submission of an
Environmental Assessment as defined in section 1.1311.

The below calculations define the minimum safe working distance for both Occupational
and General Public, which are based on the maximum permissible exposure limits of 5
mW/cm2 and 1 mW/cm2 respectively. These calculations were conducted using the
highest gain antenna used in this operation. The antenna is patch antenna array with a
maximum 8 degree beam width.

TX Peak Power (mW)                   5000.00
TX Peak Power (dBm)                    36.99
Maximum Antenna Gain dBi               23.00
EIRP (dBm)                             59.99
Maximum Duty Cycle (Dc)                 1.00

EIRP Watts                            997.63
Avg EIRP Watts                        997.63

TX Avg Power mW (Pavg)
Pp*Dc                                5000.00

Non Dimensional Antenna
Gain
       dBi/10
Gt = 10                         199.5262315
                               Occupational            General Public
Minimum Safe Distance -
Meters                                  1.27                              2.85

Distance in Centimeters (R)              127                               285

AVG Power Density
mW/CmCm
Pd At distance=R
                   2
(Pavg*Gt)/(4*Pi)*R              4.922125677                       0.977395692
                                Max Value 5              Max Value 1


                       Environmental Assessment
                           Insitu Proprietary
The antenna will be operated in a controlled area, and will be directed towards the aircraft
in flight. Only authorized occupational workers will be allowed access to the area of
operation. In addition the transmitter will be secured prior to conducting maintenance,
and the area will be monitored during the operation to ensure that personnel are clear of
any radiation hazard area.