Toggle navigation
FCC.report
IBFS
ELS
FCC ID
Contact
About
FCC.report
›
ELS
›
Hughes Network Systems, Inc.
›
0651-EX-ST-2004
Hughes Network Systems, Inc.
0651-EX-ST-2004
Status: Denied/Dismissed
WD2XFP
2004-11-18
Documents and Communications:
[
refresh
]
Description
Category
Date
E-Mail generated [Nov 17 2004]
Correspondence
2004-11-17
Dismissal Without Prejudice generated [Nov 18 2004]
Correspondence
2004-11-18
Cancellation Request
Text Documents
2004-11-18
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY
Applicant Name
Name of Applicant:
Hughes Network Systems, Inc.
Address
Attention:
Steven Doiron
Street Address:
11717 Exploration Lane
P.O. Box:
City:
Germantown
State:
MD
Zip Code:
20876
Country:
E-Mail Address:
[email protected]
Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:
Last Name:
Janka
First Name:
John
Title:
Attorney
Phone Number:
202-637-2200
Explanation
Please explain in the area below why an STA is necessary:
HNS is applying for this STA with this modification for an experimental license to ensure that testing of additional terminal types can continue. The purpose of this STA is to facilitate commercial production of SPACEWAY terminals so that the terminals will be available upon launch of the satellite.
Purpose of Operation
Please explain the purpose of operation:
Testing of Ka band earth station terminals in the SPACEWAY satellite system using the HNS Ka band Satellite Simulation Test Range at the HNS headquarters in Germantown, MD.
Information
Callsign:
WD2XFP
Class of Station:
FX
Nature of Service:
Experimental
Requested Period of Operation
Operation Start Date:
08/16/2004
Operation End Date:
11/16/2004
Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:
Manufacturer
Model Number
No. Of Units
Experimental
Hughes Network Systems, Inc.
1033128-1
40
No
Hughes Network Systems, Inc.
1033084-1
40
No
Hughes Network Systems, Inc.
1035636-1
40
No
Hughes Network Systems, Inc.
1035813-1
40
No
Hughes Network Systems, Inc.
1030593-1
40
No
Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form):
Title of Applicant (if any):
Date:
2004-11-12 16:56:08.653
Station Location
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 43
West 77 14 41
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.90
(b) Orientation in horizontal plane:
302.00
(c) Orientation in vertical plane:
2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
19700.00000000-20200.00000000 MHz
FX
10.000000 nW 385.000000 uW
M
500MG7W
QPSK
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 46
West 77 14 49
1.00
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
1.10
(b) Orientation in horizontal plane:
125.00
(c) Orientation in vertical plane:
-2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 67.200000 kW
M
20M9G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 67.200000 kW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
1.000000 W 16.800000 kW
M
650KG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 46
West 77 14 49
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.60
(b) Orientation in horizontal plane:
125.00
(c) Orientation in vertical plane:
2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 233.000000 kW
M
20M9G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 233.000000 kW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
1.000000 W 58.200000 kW
M
650KG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 46
West 77 14 49
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.45
(b) Orientation in horizontal plane:
125.00
(c) Orientation in vertical plane:
2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
10.000000 W 1.300000 MW
M
20M9G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
4.000000 W 520.000000 kW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
1.000000 W 130.000000 kW
M
650KG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 46
West 77 14 49
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.70
(b) Orientation in horizontal plane:
125.00
(c) Orientation in vertical plane:
-2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
4.000000 W 153.800000 kW
M
20M9G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
4.000000 W 153.800000 kW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
Modified
29500.00000000-30000.00000000 MHz
FX
1.000000 W 38.500000 kW
M
650KG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 46
West 77 14 49
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.70
(b) Orientation in horizontal plane:
125.00
(c) Orientation in vertical plane:
-2.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 88.500000 kW
M
20M9G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
4.000000 W 88.500000 kW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29500.00000000-30000.00000000 MHz
FX
1.000000 W 22.100000 kW
M
650KG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 45
West 77 14 52
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.70
(b) Orientation in horizontal plane:
132.00
(c) Orientation in vertical plane:
0.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
19.70000000-20.20000000 GHz
FX
50.000000 mW 2.900000 kW
M
500MG7W
City
State
Latitude
Longitude
Mobile
Radius of Operation
Germantown
Maryland
North 39 10 45
West 77 14 52
Datum:
NAD 83
Is a directional antenna (other than radar) used?
Yes
Exhibit submitted:
No
(a) Width of beam in degrees at the half-power point:
0.20
(b) Orientation in horizontal plane:
132.00
(c) Orientation in vertical plane:
0.00
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?
No
(a) Overall height above ground to tip of antenna in meters:
(b) Elevation of ground at antenna site above mean sea level in meters:
(c) Distance to nearest aircraft landing area in kilometers:
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29.50000000-30.00000000 GHz
FX
1.000000 W 473.000000 kW
M
650KG7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29.50000000-30.00000000 GHz
FX
4.000000 W 1.892000 MW
M
2M61G7W
Action
Frequency
Station Class
Output Power/ERP
Mean Peak
Frequency Tolerance (+/-)
Emission Designator
Modulating Signal
New
29.50000000-30.00000000 GHz
FX
35.000000 W 16.560000 MW
M
20M9G7W
68649
© 2024 FCC.report