Harris Corporation

0619-EX-ST-2017

Status: Grant Expired Due to New License

WL9XJG
2017-06-12

Documents and Communications: [refresh]

DescriptionCategoryDate
Grant E-mail Notification generated [Jun 13 2017]Correspondence2017-06-13
Supplemental STA ExhibitText Documents2017-05-31
Exhibit 1 Request for STAText Documents2017-05-11
Further Supplement and AmendmentText Documents2017-06-06
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Harris Corporation

Address
Attention: Attn: Bill LeBeau, Holland & Knight LLP
Street Address: 800 17th Street, N.W., Suite 1100
P.O. Box:
City: Washington
State: DC
Zip Code: 20006
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: LeBeau
First Name: Bill
Title: FCC Legal Counsel to Applicant
Phone Number: (202)862-5965

Explanation
Please explain in the area below why an STA is necessary:
See Exhibit 1

Purpose of Operation
Please explain the purpose of operation:  Experimental interoperability testing and demonstrations of wideband waveform for the US Air Force

Information
Callsign: WL9XJG
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 07/28/2017
Operation End Date: 08/31/2017

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
Harris Corp RF-7800H 2 Yes

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Stephen Kaiser
Title of Applicant (if any): Applications Engineer
Date: 2017-05-11 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Yigo Guam North  13  35  15 East  144  55  28
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10200.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10400.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10600.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 10800.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 11550.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 12090.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 13850.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 14550.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15760.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15860.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 15960.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16060.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 16160.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 17450.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0V1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18040.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 18610.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 19460.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20460.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 20960.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 21860.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 22860.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23160.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 23460.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 24460.00000000- kHz FX 1.500000 kW 1.500000 kW P 24K0J1D

49054

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC