E-Mail generated [Dec 1 2016]

0267-EX-CN-2016 Correspondence

General Dynamics

2016-12-01ELS_185004

To: Gil Estrella
E-Mail: Gil.Estrella@gd-ms.com
From: Doug Young
Date: December 01, 2016

Subject: Request for Info - File #0267-EX-CN-2016
----------------------------------------------------------------------------------------------------------------------------
Message:

It appears that you have used a d = 0 meters (antenna against outside wall) in the formula in 8.3.28(f) of
the NTIA Manual. This means that your EIRP should be 39.3 pW, which equals 24 pW ERP. You have
entered 63.1 pW ERP in Form 442. Your antenna would have to be roughly 19 meters from the nearest
outside wall to be allowed to use 63.1 pW ERP, but I don’t see that in your calculations. Explain.

The items indicated above must be submitted before processing can continue on the above referenced
application. Failure to provide the requested information within 30 days of December 01, 2016 may result
in application dismissal pursuant to Section 5.67 and forfeiture of the filing fee pursuant to Section
1.1108.

DO NOT Reply to this email by using the 'Reply' button. In order for your response to be processed
expeditiously, you must upload your response via the Internet at https://apps.fcc.gov/oetcf/els/index.cfm
by clicking on the "Reply to Correspondence" hyperlink.


Responses to this correspondence must contain the Reference number : 34858



Document Created: 2016-12-01 10:07:35
Document Modified: 2016-12-01 10:07:35