Fail-Safe Solutions, LLC

0271-EX-ST-2017

Status: Grant Expired Due to New License

WK9XLW
2017-05-11

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Mar 21 2017]Correspondence2017-03-21
Incoming generated [Mar 21 2017]Correspondence2017-03-21
Grant E-mail Notification generated [May 11 2017]Correspondence2017-05-11
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
E-Mail generated [Mar 21 2017]Correspondence2017-03-21
Incoming generated [Mar 21 2017]Correspondence2017-03-21
Grant E-mail Notification generated [May 11 2017]Correspondence2017-05-11
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Project DescrptionImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
Stop Contact InformationImages2017-03-06
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Fail-Safe Solutions, LLC

Address
Attention: Alex Hartley
Street Address: 13919-B N May Ave
P.O. Box: 213
City: Oklahoma City
State: OK
Zip Code: 73134
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Hartley
First Name: Alex
Title: Senior Information Systems Technician
Phone Number: 580-362-6725

Explanation
Please explain in the area below why an STA is necessary:
This authorization is to fulfill a government contract training requirement with an agency of the United States Military.

Purpose of Operation
Please explain the purpose of operation:  The operation supports a Military training exercise with specific frequency sets.

Information
Callsign: WK9XLW
Class of Station: MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 07/01/2017
Operation End Date: 09/30/2017

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
EMCEE Communications TTU100CQ 2 No
Motorola XPR 3500 7 No
Motorola XPR 3500 7 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Donald A Hartley
Title of Applicant (if any): Senior Range Technician
Date: 2017-03-06 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Braggs Oklahoma North  35  40  15 West  95  10  13 Within confines of Camp Gruber, Braggs, OK 10.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 138.05000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 138.42500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 138.65000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 139.10000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 139.35000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Fr
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 139.77500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E f
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 140.05000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 140.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 140.85000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 141.00000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 170.12500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 170.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 171.25000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 172.37500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 172.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 173.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 453.12500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 453.70000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 454.10000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 454.32500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 454.80000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 455.05000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 455.42500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 456.65000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 458.00000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 458.75000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 459.77500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 466.05000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 466.75000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 467.85000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 468.12500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 468.25000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 468.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 469.37500000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 469.75000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 470.55000000- MHz MO 5.000000 W 4.980000 W M 0.00010000 % 12K5F9E Frequency Modulation

69116

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC