Question 9 Statement of Environmental Impact

0644-EX-PL-2011 Text Documents

ELTA North America

2011-12-21ELS_121755

ELTA North America Request for FCC Experimental License

Form 442 File Number: 0644-EX-PL-2011
Form 442 Confirmation Number: EL939980
21 December 2011


Question 9: Statement of Environmental Impact

ELTA North America (N.A.) will occupy a section of the building located at 11840 West Market
Place, Fulton, MD. The building is a new, single-story structure, with multiple bays, and is
constructed of concrete block with a web girder and steel pan roof. The surrounding area is a
mixed use development of retail, office, educational, and residential buildings. The adjacent
property consists of similar single-story buildings to the north and south of the site, a public
school campus to the west, and an open field to the east. Further north is a residential
neighborhood and the Johns Hopkins University (JHU) Applied Physics Laboratory (APL)
campus. Further east is a small urban development with multistory buildings. The antenna will
be mounted on top of a four to six foot mast which will be located on the roof. The radar
equipment will be remotely controlled from inside the building.

It is the policy of ELTA N.A. that company personnel, customers, or members of the public are
not subjected to RF power density levels that exceed the Maximum Permissible Exposure (MPE)
limits as given in Part 1.1310 of the FCC Rules. Experimental testing will only be conducted
with appropriate controls in place, and no personnel will be on the roof during transmissions that
will exceed the MPE levels. ELTA N.A. will have an RF Safety Plan which describes the
procedures and controls necessary to comply with MPE levels during operations and
maintenance. Measurements will also be used to confirm that MPE levels are not exceeded.

ELTA N.A. conducted a worst-case analysis of power density levels in the area surrounding the
transmitting antenna based on the FCC's OET Bulletin Number 651. The applicable radar
parameters and results are shown in Tables 1 and 2, respectively. The MPE limit is exceeded for
areas within 5.3 and 11.8 feet for controlled and uncontrolled exposure limits, respectively. With
the building height of approximately 19 feet, personnel on the ground will be beyond the
distance where the power density exceeds the MPE limit. For personnel on the roof, the roof has
controlled access; therefore, appropriate controls will be implemented for areas within 5.3 ft
during test periods. Measurements will be made to confirm the emission levels.




1
 Cleveland, Robert F., et al., Evaluating Compliance with FCC Guidelines for Human Exposure to Radiofrequency
Electromagnetic Fields, Edition 97-01, OET BULLETIN 65, Washington D.C.: Federal Communications
Commission, Office of Engineering and Technology, August 1997.


               Table 1 – Power Density Analysis
                     Parameter                Value
         Operational frequency, MHz           10250
         Transmitter output power (peak), W    10
         Antenna gain (mainbeam), dBi          18
         Ground reflection factor              1.6


           Table 2 – Power Density Analysis Results
              Parameter                  Controlled   Uncontrolled
Maximum Permissible Exposure, mW/cm2         5             1
Minimum required distance, meters           1.6           3.6
Minimum required distance, feet             5.3          11.8