Dassault Falcon Jet Corp

0966-EX-ST-2012

Status: Grant Expired Due to New License

WG9XGP
2013-02-26

Documents and Communications: [refresh]

DescriptionCategoryDate
E-Mail generated [Jan 18 2013]Correspondence2013-01-18
Incoming generated [Jan 28 2013]Correspondence2013-01-28
Grant E-mail Notification generated [Feb 27 2013]Correspondence2013-02-27
GSMConnexOnAirImages2013-01-28
OnAIrText Documents2013-01-30
GSMConneXOnAirText Documents2013-01-28
GSMConneXOnAirText Documents2013-01-28
GSMConnexOnAirText Documents2013-01-28
GSMConnex OnAir system descriptionText Documents2013-01-28
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  Dassault Falcon Jet Corp

Address
Attention: Vu Ha Nguyen
Street Address: 3801 E. 10th Street
P.O. Box:
City: Little Rock
State: AR
Zip Code: 72202-3366
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Nguyen
First Name: Vu Ha
Title: Engineer
Phone Number: 5013012169

Explanation
Please explain in the area below why an STA is necessary:
a STA is necessary to perform ground test on aircraft equipped with the GSMConneX system, which allows to use the cellphone on onboard. This system control the RF transmission onboard aircraft in order to prevent Mobile Phones from accessing terrestrial network.

Purpose of Operation
Please explain the purpose of operation:  Equipment testing functional test: - use the GSMCOnneX system on ground with the frequency jammer in active position - perform one or several calls and texts from A/C to ground and from ground to A/C

Information
Callsign: WG9XGP
Class of Station: FX
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 01/14/2013
Operation End Date: 04/15/2013

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
TriaGnoSys 21T810-02-01-00 1 No
TriaGnoSys 21T811-00-01-00 1 No
TriaGnoSys 21T820-00-01-00 1 No
Miltope 902693-1 1 No

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Vu Ha NGUYEN
Title of Applicant (if any): Engineer
Date: 2012-12-11 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
Little Rock Arkansas North  34  44  9 West  92  14  1 the antenna (leaky line antenna) will be installed on aircraft but test will be performed at the same area 1.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   No
(a) Overall height above ground to tip of antenna in meters:  
(b) Elevation of ground at antenna site above mean sea level in meters:  
(c) Distance to nearest aircraft landing area in kilometers:  
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft:
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 420.00000000-430.00000000 MHz FX N/A 6.300000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 460.00000000-470.00000000 MHz FX N/A 6.300000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 810.00000000-826.00000000 MHz FX N/A 12.600000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 869.00000000-894.00000000 MHz FX N/A 20.000000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 921.00000000-960.00000000 MHz FX N/A 5.000000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1724.90000000-1725.10000000 MHz FX N/A 1.000000 mW G7W
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1805.00000000-1880.00000000 MHz FX N/A 20.000000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1819.90000000-1820.10000000 MHz FX N/A 10.000000 mW G7W
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 1930.00000000-1990.00000000 MHz FX N/A 20.000000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2110.00000000-2170.00000000 MHz FX N/A 16.000000 mW XXN
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 2620.00000000-2690.00000000 MHz FX N/A 16.000000 mW XXN

30328