                           Current Technologies, LLC
                    Experimental License Progress Report #13

        Under its experimental license, Current Technologies, LLC (“Current”) has
been operating its proprietary broadband over powerline (“BPL”) communications
equipment installed on both low voltage and medium voltage electric power
distribution lines. This BPL equipment forms a communications path that safely
bypasses the step-down transformer segregating the low and medium voltage
power lines. These experimental operations continue to validate the capabilities
of BPL technology. Current’s proprietary BPL equipment continuously delivers
always-on, symmetrical broadband speeds to virtually all of the existing electrical
outlets in the customer premises.

      Current’s experimental BPL operations to date have enabled Current to
develop and verify or certify its BPL equipment under applicable FCC Part 15
emissions requirements and to commence the manufacture and distribution of
commercial equipment. Current has received no interference complaints, nor
has any interference been detected, during any of its experimental operations.

        Most of the activity during this reporting period has focused on detailed
engineering, testing, verification, and certification of Current’s third-generation
BPL equipment, including development of components that delivers improved
“Smart Grid” functionality that increases the reliability, security and efficiency of
electric distribution networks. These experimental operations have validated
significant cost reductions and functionality improvements in Current’s BPL
systems. During this reporting period Current received FCC certification for three
new equipment configurations.

       Current has continued to test equipment operating on frequencies both
above and below 30 MHz. The results continue to confirm that peak emission
levels emanate from the precise point on which Current’s BPL equipment is
coupled to the electric distribution line and that such emissions dissipate in a
monotonically decreasing fashion as the measurement point moves further from
the equipment coupling point. Specifically, RF signal strength from Current’s low
and medium voltage BPL equipment falls off with the inverse square of distance,
so that the devices act quantitatively like point source emitters.

        Testing continues to confirm that maximum radiated emissions for
equipment operating both above and below 30 MHz comply with applicable Part
15 emissions limits and are similar at all tested installation sites with no
statistically significant variations. All measurements are taken in accordance with
the procedures prescribed in 47 CFR § 15.31 and the Commission’s October 28,
2004 Report and Order in Docket No. 04-37.