Bandwidth Calculation

0535-EX-PL-2006 Text Documents

Cellco Partnership

2007-08-14ELS_83425

                                                                          FCC Form 442
                                                                              Exhibit 2
                                                                            Page 1 of 2
                                 Bandwidth Calculation

The occupied bandwidth of the CDMA transmission signal from the type accepted base
station was determined by measuring the 99% power bandwidth per 47CFR Section 2.02.
This measurement supports the experimental license application for the Verizon Wireless
Southlake Lab. The nominal bandwidth of a CDMA signal is 1.25 MHz (+/- 625 KHz.)
around the center frequency of the transmitted signal. The measurement resulted in an
occupied bandwidth with the expected bandwidth. These channels will be operated at
very low power within an RF shielded room on a non-interfering basis.

Test Setup

The spectral plot was taken with an Agilent E7495B Base Station Test Set which was
located within the RF shielded enclosure. The test equipment input was cabled to the RF
shield room bulkhead connector which is directly cabled to the base station through a RF
switch box. The signal level presented to the test set was approximately -68 dBm, which
is the same as normally presented to an antenna within the RF shield room. The test set
was programmed to calculate the power bandwidth with a 99% power setting.

Test Results

The resulting bandwidth calculated by the base station test set was 1.196 MHz. This is
less than the nominal bandwidth of 1.2288 MHz of a Cellular CDMA signal.
The following screen capture from the test set spectral plot shows the measurement
results.


FCC Form 442
    Exhibit 2
  Page 2 of 2



Document Created: 2007-08-14 11:59:29
Document Modified: 2007-08-14 11:59:29

© 2024 FCC.report