BlockDiagram and Description

0327-EX-PL-2010 Text Documents

BridgeWave Communications, Inc.

2010-08-10ELS_109351

                                         FlexPort™- 23 Block Diagram
                    Digital Board          Signal Processing Unit (SPU)          Radio Frequency Unit (RFU)

                                                       Control
                                                                            µP               RX LO PLL,
        µP                                             Interface
                                                                                         RX Channel Selection


                                                                           RX IF            Down
                                                                     ADC
                                                                           AMP             Converter


                           Framing,                                                           LNA
    Ethernet               Coding &                  Digital




                                                                                                                    Antenna
                                                                                                         Diplexer
     Switch              Configuration         Signal Processing           Reference
                            Circuit          Modulator-Demodulator         Oscillator
                                                    Circuit
                                                                                            TX Amp


               x5
               ports                                                         TX IF            UP
                                                                     DAC
                                                                             AMP           Converter


                                                                                              TX LO PLL,
                                                   Main                                   TX Channel Selection
                               Power                                       Power
                                                  Power
                               Supply                                      Supply
   Ethernet &                                     Supply
   SFP Ports



Traffic Interface                                 DC Input




                                               BridgeWave CONFIDENTIAL


                      FP-23 Technical Description
 TX
1.    Ethernet traffic payload enters the TX side through transceiver interfaces. Ethernet traffic goes into
      the managed Ethernet switch on the Digital board. The Ethernet switch passes the data to the
      framing, coding & configuration circuit.
2.    The framed and coded traffic data is then sent to the SPU board.
3.    The digital traffic data is modulated in the SPU and then Digital to Analog Converted (DAC) ,
      producing the TX IF signal.
4.    The TX IF signal is then passes through a TX IF AGC and is for up-converted and amplified in the
      Radio Frequency Unit (RFU).
5.    The RF TX signal then passes through the Diplexer and out the Antenna.

 RX

1.    The RF Receive signal comes through the antenna and diplexer into the LNA and is down-converted
      to IF Frequency
2.    The RX IF signal then passes through a RX IF AGC amplifier in the RFU.
3.    The RX IF signal is Analog to Digital Converted (ADC) on the SPU and demodulated.
4.    The RX demodulator then outputs the framed and coded data to the DIGITAL board.
5.    The DIGITAL board removes framing and coding and then the traffic then goes to the Ethernet
      switch
6.    The Ethernet traffic payload exits the system via transceiver interfaces.