BNSF Railway Co.

0268-EX-ST-2016

Status: Grant Expired Due to New License

WJ9XNW
2016-04-07

Documents and Communications: [refresh]

DescriptionCategoryDate
Grant E-mail Notification generated [Apr 5 2016]Correspondence2016-04-05
FAA Antenna PhotoImages2016-03-07
FAA Antenna PhotoImages2016-03-07
Base Antenna Tower StructureImages2016-03-03
Application Form:
OET Special Temporary Authority Report
FEDERAL COMMUNICATIONS COMMISSION
APPLICATION FOR SPECIAL TEMPORARY AUTHORITY

Applicant Name
Name of Applicant:  BNSF Railway Co.

Address
Attention: BNSF Telecom FCC
Street Address: 4515 Kansas Ave.
P.O. Box:
City: Kansas City
State: KS
Zip Code: 66106
Country:
E-Mail Address: [email protected]

Best Contact
Give the following information of person who can best handle inquiries pertaining to this application:  
Last Name: Barrett
First Name: Jim
Title: Authorized Employee
Phone Number: 817-352-6450

Explanation
Please explain in the area below why an STA is necessary:
BNSF is requesting an Experimental Special Temporary Authorization for the purpose of UAV Command and Control testing.

Purpose of Operation
Please explain the purpose of operation:  An experimental Special Temporary Authorization is requested for the purpose of communicating command and control messages to unmanned aerial vehicles (UAV).

Information
Callsign: WJ9XNW
Class of Station: FX MO
Nature of Service: Experimental

Requested Period of Operation
Operation Start Date: 04/07/2016
Operation End Date: 09/29/2016

Manufacturer
List below transmitting equipment to be installed (if experimental, so state) if additional rows are required, please submit equipment list as an exhibit:  
Manufacturer Model Number No. Of Units Experimental
ARINC / Rockwell Collins CNPC-1000 10 Yes
ARINC / Rockwell Collins CNPC 1000 10 Yes

Certification
Neither the applicant nor any other party to the application is subject to a denial of Federal benefits that includes FCC benefits pursuant to Section 5301 of the Anti-Drug Abuse Act of 1988, 21 U.S.C. Section 862, because of a conviction for possession or distribution of a controlled substance. The applicant hereby waives any claim to the use of any particular frequency or electromagnetic spectrum as against the regulatory power of the United States because of the prvious use of the same, whether by license or otherwise, and requests authorization in accordance with this application. (See Section 304 of the Communications Act of 1934, as amended.) The applicant acknowledges that all statements made in this application and attached exhibits are considered material representations, and that all the exhibits part hereof and are incorporated herein as if set out in full in this application; undersigned certifies that all statements in this application are true, complete and correct to the best of his/her knowledge and belief and are made in good faith. Applicant certifies that construction of the station would NOT be an action which is likely to have a significant environmental effect. See the Commission's Rules, 47 CFR1.1301-1.1319.
Signature of Applicant (Authorized person filing form): Jim Barrett
Title of Applicant (if any): Authorized Employee
Date: 2016-02-29 00:00:00.0

Station Location
City State Latitude Longitude Mobile Radius of Operation
PLAYAS New Mexico North  31  54  10 West  108  31  29 24.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   30.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1421.00
(c) Distance to nearest aircraft landing area in kilometers:   3.87
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: None
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.88125000-896.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.93125000-896.94375000 kHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.98125000-896.99375000 kHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.88125000-897.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.93125000-897.94375000 MHz FX 1.420000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.98125000-897.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.88125000-935.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.93125000-935.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.98125000-935.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.88125000-936.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.93125000-936.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 936.98125000-936.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D

City State Latitude Longitude Mobile Radius of Operation
PLAYAS New Mexico North  31  54  10 West  108  31  29 24.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   27.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1421.00
(c) Distance to nearest aircraft landing area in kilometers:   3.87
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: None
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.88125000-896.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.93125000-896.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 896.98125000-896.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 896.98125000-896.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.88125000-897.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.93125000-897.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.98125000-897.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.88125000-935.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.88125000-935.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.93125000-935.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.98125000-935.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.98125000-935.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.88125000-936.89375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.93125000-936.94375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
Modified 936.98125000-936.99375000 MHz FX 1.410000 W 1.410000 W P 8K20F3D

City State Latitude Longitude Mobile Radius of Operation
North  31  54  10 West  108  31  29 Playas, NM 24.00
Datum:  NAD 83
Is a directional antenna (other than radar) used?   No
Exhibit submitted:   No
(a) Width of beam in degrees at the half-power point:  
(b) Orientation in horizontal plane:  
(c) Orientation in vertical plane:  
Will the antenna extend more than 6 meters above the ground, or if mounted on an existing building, will it extend more than 6 meters above the building, or will the proposed antenna be mounted on an existing structure other than a building?   Yes
(a) Overall height above ground to tip of antenna in meters:   91.00
(b) Elevation of ground at antenna site above mean sea level in meters:   1421.00
(c) Distance to nearest aircraft landing area in kilometers:   3.87
(d) List any natural formations of existing man-made structures (hills, trees, water tanks, towers, etc.) which, in the opinion of the applicant, would tend to shield the antenna from aircraft: None
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.88125000-896.89375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.93125000-896.94375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 896.98125000-896.99375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.88125000-897.89375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.93125000-897.94375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 897.98125000-897.99375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.88125000-935.89375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.93125000-935.94375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 935.98125000-935.99375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.88125000-936.89375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.93125000-936.94375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D
Action Frequency Station Class Output Power/ERP Mean Peak Frequency Tolerance (+/-) Emission Designator Modulating Signal
New 936.98125000-936.99375000 MHz MO 1.160000 W 1.160000 W P 8K20F3D