Exhibit

5444-EX-RR-1997 Text Documents

AMERICAN BROADCASTING COMPANIES, INC.

1999-03-01ELS_3608

                                            Exhibit 1
                                Radiation Hazard Summary Table
                               Washington News Bureau INMARSAT

                                        Calculated
                                      Radiation Level
Region                               with Max. Power             Hazard Assessment
                                         (mWicm*)
Far Field, R = 7.38 m                     0.73                   Complies with Guidelines

Near Field, R, = 3.07 m                   4.53                   Potential Hazard (accessible to
                                                                 operating personnel, complies with
                                                                 guidelines for operating personnel; will
                                                                 be entered only with power off)

Transition Region, R                    <4.53                    Potential Hazard (accessible to
R, <R, <R;                                                       operating personnel, complies with
                                                                 guidelines for operating personnel; will
                                                                 be entered only with power off)

Between Feed and Reflector               <318                    Potential Hazard (accessible to
                                                                 operating personnel, will be entered
                                                                 only with power off)

Reflector Surface                         1.41                   Potential Hazard (accessible to
                                                                 operating personnel, complies with
                                                                 guidelines for operating personnel; will
                                                                 be entered only with power off)

Level Around Antenna                      <4.53                  Potential Hazard (accessible to
                                                                 operating personnel, complies with
                                                                 guidelines for operating personnel; will
                                                                 be entered only with power off)


CONCLUSION: Based on the above analysis it is concluded that harmful levels of radiation will
not exist in regions normailly occupied by the public or the earth—station‘s operating personnel. The
earth station is marked with the standard radiation hazard warnings warning personnel! to avoid
the area in front of the reflector when the transmitters are operational. To ensure compliance with
the safety limits, the earth station transmitters will be turned off whenever maintenance and repair
personnel are required to work in an area where the radiation level exceeds the level
recommended by applicable guidelines. Additionally, access to the earth station is controlled by
the operator.
                                            September 29, 1997                                       KE2ZXAE