Historical Consolidated Database System
20040607AAR
This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.
Application details
| CDBS application ID | 997394 |
|---|---|
| Application reference number | 20040607AAR |
| Service | FM |
| Application type | P |
| File prefix | BPED |
| Call sign | WABE |
| Facility ID | 3538 |
| Community | ATLANTA, GA |
| Channel | 211 |
| Frequency | 90.100000 MHz |
| Status | GRANT |
| Status date | 2004-06-15 |
| Accepted | 2004-06-08 |
| Construction permit expiration | 2007-06-15 |
Applicant
| Name | BOARD OF EDUCATION OF THE CITY OF ATLANTA |
|---|---|
| Address | 740 BISMARK ROAD, N.E., ATLANTA, GA, 30324 |
| Phone | 4048278000 |
| [email protected] |
Broadcast facility
| Facility ID | 3538 |
|---|---|
| Call sign | WABE |
| Service | FM |
| Status | LICEN |
| License expiration | 2028-04-01 |
| Channel | 211 |
| Frequency | 90.100000 MHz |
| Community | ATLANTA, GA |
Current LMS continuation
The FCC transfer table maps this historical application to BPED-20040607AAR.
Application parties
| Role | Name | FRN | Location | Relationship or certification |
|---|---|---|---|---|
| APPLI | BOARD OF EDUCATION OF THE CITY OF ATLANTA | ATLANTA, GA | ||
| CNREP | SCHWARTZ, WOODS & MILLER | |||
| APCRT | MIKE HOLIMAN | BOARD CHAIR | ||
| CRTEN | JEFFERSON G. BROCK | ST. SIMONS ISLAND, GA | TECHNICAL CONSULTANT |
Engineering records
| Service | Assignment | Status / class | Power | Antenna | Coordinates | ASR | Height |
|---|---|---|---|---|---|---|---|
| FM | Channel 211 / 90.100000 MHz | CP / C1 / A | D | 33.75888889, -84.33527778 | 1217309 | 277.000 m HAAT |
Call sign history
| Call sign | Effective | Record changed |
|---|---|---|
| WPBA-FM | 1984-05-10 | |
| WABE | 1984-04-10 | |
| WABE-FM | 1981-12-01 |
Related FCC records
| System or type | Record | Relationship |
|---|---|---|
| FACILITY | Facility 3538 | Concerns Facility |
| FILING | 1015294 | Concerns Facility |
| FILING | 1016283 | Concerns Facility |
| FILING | 1017980 | Concerns Facility |
| FILING | 1018598 | Uses Structure |
| FILING | 1045390 | Concerns Facility |
| FILING | 1107592 | Concerns Facility |
| FILING | 1144079 | Uses Structure |
| FILING | 1163349 | Concerns Station |
| FILING | 1198644 | Concerns Facility |
| FILING | 121310 | Concerns Station |
| FILING | 137566b5a5fa45729fe1c1b6063ebeb7 | Concerns Station |
| FILING | 143190 | Concerns Station |
| FILING | 1454054 | Concerns Facility |
| FILING | 1454066 | Concerns Station |
| FILING | 1498792 | Concerns Station |
| FILING | 1501272 | Concerns Facility |
| FILING | 1510495 | Concerns Station |
| FILING | 151465 | Concerns Station |
| FILING | 1521585 | Uses Structure |
| FILING | 177547 | Concerns Facility |
| FILING | 186227 | Concerns Facility |
| FILING | 18e815ea1a134b89bd41c1b6063ebeb7 | Concerns Facility |
| FILING | 194574 | Concerns Facility |
| FILING | 203fc507b0e847739ec1c1b6063ebeb7 | Concerns Station |
| FILING | 217308 | Concerns Station |
| FILING | 226641c762fd40c28281c1b6063ebeb7 | Concerns Station |
| FILING | 25076f914fe0efff015042adb4b73440 | Uses Structure |
| FILING | 36567 | Concerns Station |
| FILING | 48058 | Concerns Station |
| FILING | 485156 | Concerns Station |
| FILING | 485157 | Concerns Station |
| FILING | 485158 | Concerns Facility |
| FILING | 485159 | Concerns Station |
| FILING | 500287 | Concerns Facility |
| FILING | 501801 | Uses Structure |
| FILING | 508859 | Concerns Facility |
| FILING | 517466 | Concerns Station |
| FILING | 5313 | Concerns Station |
| FILING | 55155 | Concerns Station |
| FILING | 56746 | Concerns Station |
| FILING | 58671 | Concerns Station |
| FILING | 591332 | Concerns Facility |
| FILING | 6413 | Concerns Station |
| FILING | 702529 | Concerns Facility |
| FILING | 702532 | Concerns Station |
| FILING | 88681 | Concerns Station |
| FILING | ada4c6debb7d46d9a8d0c1b6063ebeb7 | Continued As |
| STRUCTURE | ASR 1217309 | Uses Structure |