Historical Consolidated Database System

20000428ACK

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID607382
Application reference number20000428ACK
ServiceDT
Application typeP
File prefixBPEDT
Call signWMTJ-DT
Facility ID2174
CommunityFAJARDO, PR
Channel16
StatusGRANT
Status date2002-07-29
Accepted2000-06-07
Cutoff date2001-01-18
Construction permit expiration2004-08-04
Amendment stamped2002-07-19
Last CDBS change2001-09-13

Applicant

NameSISTEMA UNIVERSITARIO ANA G. MENDEZ, INC.
AddressP.O. BOX 21345, RIO PIEDRAS, PR, 00928
Phone7877662700
Email[email protected]

Broadcast facility

Facility ID2174
Call signWMTJ
ServiceDT
StatusLICEN
Status date2019-01-09
License expiration2021-02-01
Channel15
Frequency476.000000 MHz
CommunityFAJARDO, PR

Current LMS continuation

The FCC transfer table maps this historical application to BPEDT-20000428ACK.

Application parties

RoleNameFRNLocationRelationship or certification
APPLISISTEMA UNIVERSITARIO ANA G. MENDEZ, INC.RIO PIEDRAS, PR
CNREPDOW, LOHNES & ALBERTSON, PLLC
APCRTJOSE F. MENDEZPRESIDENT
CRTENJOHN F.X. BROWNE, P.E.BLOOMFIELD HILLS, MICONSULTING ENGINEER

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 16CP / A150.000000 kW ERPD C18.31000000, -65.7947222210114691045.000 m AMSL

Call sign history

Call signEffectiveRecord changed
WMTJ1983-01-24
820507KH

Related FCC records

System or typeRecordRelationship
FACILITYFacility 2174Concerns Facility
FILING03f9a6ebc5ae4c9ea343c1b6063ebeb7Uses Structure
FILING05c4a4be1efe4728b91ecf6212b6c0eaConcerns Facility
FILING0c31b6ded0124b6b9a26c1b6063ebeb7Concerns Station
FILING1017213Concerns Facility
FILING1017244Concerns Facility
FILING1017255Concerns Station
FILING1017680Concerns Station
FILING1020825Concerns Facility
FILING1037257Concerns Station
FILING1079186Uses Structure
FILING1079781Concerns Station
FILING1079802Uses Structure
FILING10e29053a564424382dfcf6212b6c0eaUses Structure
FILING1125841Uses Structure
FILING1135280Uses Structure
FILING1140056Uses Structure
FILING1151518Concerns Station
FILING1155693Uses Structure
FILING1159774Uses Structure
FILING1161793Concerns Station
FILING1169702Uses Structure
FILING1191527Concerns Facility
FILING1201ad68c9dc4d9ab62ec1b6063ebeb7Uses Structure
FILING1222168Concerns Station
FILING1230831Concerns Station
FILING1234090Uses Structure
FILING1236056Concerns Facility
FILING1239957Uses Structure
FILING1248483Uses Structure
FILING1250913Concerns Facility
FILING1251129Uses Structure
FILING1254808Concerns Facility
FILING1256241Concerns Station
FILING1257046Uses Structure
FILING1257194Uses Structure
FILING1264883Concerns Facility
FILING1265466Concerns Station
FILING1266188Concerns Facility
FILING1269019Concerns Facility
FILING1273607Concerns Facility
FILING1279284Concerns Station
FILING1281349Uses Structure
FILING1284973Concerns Station
FILING1290362Concerns Facility
FILING1294336Uses Structure
FILING1294968Uses Structure
FILING1295872Concerns Station
FILING1297547Concerns Station
FILING1299515Concerns Station
FILING1300195Concerns Station
FILING1303850Uses Structure
FILING1305390Concerns Station
FILING1315175Uses Structure
FILING1322543Concerns Facility
FILING1329381Uses Structure
FILING1345258Concerns Facility
FILING1347103Uses Structure
FILING1350878Uses Structure
FILING143859Concerns Facility
FILING165460Concerns Station
FILING1b7cf9c911c64619ab67c1b6063ebeb7Concerns Station
FILING1cf7a4e9569240a792fecf6212b6c0eaConcerns Station