Historical Consolidated Database System

19991027ADN

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID548407
Application reference number19991027ADN
ServiceDT
Application typeP
File prefixBPCDT
Call signWHOT-DT
Facility ID48813
CommunityATHENS, GA
Channel48
StatusGRANT
Status date2001-02-01
Accepted2000-01-10
Construction permit expiration2002-11-01
Amendment stamped2001-01-11

Applicant

NameUSA STATION GROUP PARTNERSHIP OF ATLANTA
AddressATTN: JULIUS GENACHOWSKI, ESQ., 1230 AVENUE OF THE AMERICAS, 15TH FLOOR, NEW YORK, NY, 10022
Phone2124136720
Email[email protected]

Broadcast facility

Facility ID48813
Call signWUVG-DT
ServiceDT
StatusLICEN
Status date2009-06-16
License expiration2021-04-01
Channel18
Frequency494.000000 MHz
CommunityATHENS, GA

Current LMS continuation

The FCC transfer table maps this historical application to BPCDT-19991027ADN.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIUSA STATION GROUP PARTNERSHIP OF ATLANTANEW YORK, NY
CNREPHOGAN & HARTSON
APCRTCHARLES SOMMERVICE PRESIDENT & SECRETARY
CRTENJOSEPH M. DAVIS, P.E.FAIRFAX, VACONSULTING ENGINEER

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 48CP / A1000.000000 kW ERPN H33.80722222, -84.339722221219417350.000 m HAAT

Call sign history

Call signEffectiveRecord changed
WUVG-DT2009-06-232009-06-23
WUVG-TV2004-01-012004-01-02
WUVG2001-11-012001-11-01
WHOT-TV1999-10-15
WNGM-TV1987-02-17
811124KF

Related FCC records

System or typeRecordRelationship
FACILITYFacility 48813Concerns Facility
FILING03202c039bd44424b7e5c1b6063ebeb7Concerns Facility
FILING037abb7788f846989a4cc1b6063ebeb7Concerns Facility
FILING06b0ff637f4842078c5dc1b6063ebeb7Concerns Station
FILING0734b3d5a69b466b8bdfc1b6063ebeb7Concerns Facility
FILING07941e0fd9d84692afc3cf6212b6c0eaConcerns Station
FILING07c40fc27aef4b47ba52c1b6063ebeb7Concerns Station
FILING0ad13d30ff824f39befdc1b6063ebeb7Concerns Station
FILING0c611d7e9e1548a49a52cf6212b6c0eaConcerns Station
FILING0d12f81d9c2b4aed94fdc1b6063ebeb7Concerns Station
FILING0d73ce52f22f4d82a287c1b6063ebeb7Concerns Facility
FILING0de897638b50426cba28cf6212b6c0eaConcerns Facility
FILING0e5acf0731f24263b8dec1b6063ebeb7Concerns Facility
FILING1003956Concerns Station
FILING1006163Concerns Station
FILING1024424Concerns Station
FILING1027693Concerns Facility
FILING1027702Concerns Station
FILING1039801Concerns Station
FILING112420Concerns Facility
FILING1136982Concerns Facility
FILING1140249Concerns Station
FILING1141562Concerns Station
FILING1142291Concerns Station
FILING1157925Concerns Facility
FILING1160999Concerns Facility
FILING117186Concerns Station
FILING1175205Concerns Facility
FILING1180044Concerns Station
FILING1180045Concerns Facility
FILING1180169Concerns Facility
FILING1183765Concerns Station
FILING1185726Concerns Station
FILING1223420Concerns Station
FILING1232934Concerns Station
FILING124920Concerns Station
FILING1255576Concerns Station
FILING1258253Concerns Station
FILING1259505Concerns Station
FILING1278685Concerns Facility
FILING1279145Concerns Facility
FILING1279639Concerns Facility
FILING127996Concerns Station
FILING1295964Concerns Facility
FILING1300320Concerns Facility
FILING1305916Concerns Station
FILING1312880Concerns Station
FILING1322520Concerns Facility
FILING1323762Concerns Station
FILING1338673Concerns Facility
FILING1346613Concerns Facility