Historical Consolidated Database System

0000177726

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID2047854
Application reference number0000177726
ServiceLD
Application typeML
File prefixBLANK
Call signKPIF-LD
Facility ID130618
CommunityTWIN FALLS, ID
Channel23
StatusSUPER
Status date2022-01-13

Applicant

NameVENTURA MEDIA COMMUNICATIONS, LLC
Address3619 VENTURA AVENUE, FRESNO, CA, 93702, US
Phone5592654326
Email[email protected]

Broadcast facility

Facility ID130618
Call signKKIF-LD
ServiceLD
StatusLICSL
Status date2023-02-13
Channel23
CommunityTWIN FALLS, ID

Current LMS continuation

The FCC transfer table maps this historical application to 0000177726.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIVENTURA MEDIA COMMUNICATIONS, LLCFRESNO, CA, US
CNREPFletcher Heald & Hildreth, PLCArlington, VA
APCRTMark ShirinManaging Member
CRTENChesapeake RF Consultants, LLCYorktown, VA
CRTENdu Treil, Lundin & Rackley, Inc.Sarasota, FL

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 23LIC / A15.000000 kW ERPD E42.72980556, -114.4144166710400351431.600 m AMSL

Call sign history

Call signEffectiveRecord changed
KKIF-LD2022-02-082022-02-08
KPIF-LD2019-11-022019-11-04
KVUT-LD2016-07-122016-07-12
K48OR-D2016-06-202016-06-20

Related FCC records

System or typeRecordRelationship
FACILITYFacility 130618Concerns Facility
FILING00f66e7a6d87403e9b06c1b6063ebeb7Uses Structure
FILING0e21badddf0d496880a9cf6212b6c0eaUses Structure
FILING1124018Uses Structure
FILING1124019Uses Structure
FILING1126125Uses Structure
FILING1126130Uses Structure
FILING112aa9d09b0b4a189410cf6212b6c0eaConcerns Facility
FILING1148177Uses Structure
FILING1148178Uses Structure
FILING1153140Uses Structure
FILING1162918Concerns Station
FILING1238358Uses Structure
FILING1248375Uses Structure
FILING1294818Uses Structure
FILING1302530Uses Structure
FILING1360851Uses Structure
FILING1367096Concerns Facility
FILING1370026Uses Structure
FILING1370800Uses Structure
FILING140771Uses Structure
FILING140985Uses Structure
FILING1426065Uses Structure
FILING1427917Uses Structure
FILING1504778Uses Structure
FILING1634648Concerns Station
FILING1727125Concerns Facility
FILING1731601Concerns Facility
FILING1749392Concerns Station
FILING1758268Concerns Station
FILING1770889Concerns Station
FILING198178Uses Structure
FILING1ad91d3403cc40d88a8dcf6212b6c0eaUses Structure
FILING1c16a7053595412cb34dcf6212b6c0eaUses Structure
FILING2004247Concerns Station
FILING2005651Concerns Station
FILING2016635Concerns Station
FILING2018256Concerns Station
FILING2021293Concerns Facility
FILING2033555Concerns Station
FILING2037427Concerns Station
FILING2043685Concerns Facility
FILING2043756Uses Structure
FILING2045262Uses Structure
FILING2045743Concerns Facility
FILING2046501Concerns Station
FILING2046817Concerns Facility
FILING2046819Concerns Facility
FILING2046852Uses Structure
FILING2048007Uses Structure
FILING2050038Concerns Facility
FILING2188f946be2549c0831bcf6212b6c0eaUses Structure
FILING25076f914e4f16d9014e69b2a2ed2517Uses Structure
FILING25076f915a4e6a8e015a86a89e3017e0Concerns Facility
FILING25076f916267d43b0162985f66904749Concerns Facility
FILING25076f916a6a0ecc016a880790f23375Concerns Facility
FILING25076ff37dda7617017de7e2122a1b48Continued As
FILING275126Uses Structure
FILING275132Uses Structure
FILING285436Uses Structure
FILING285451Uses Structure
FILING287827Uses Structure
FILING402186Uses Structure
FILING507757Uses Structure
FILING537643Concerns Station
FILING553516Uses Structure
FILING554522Uses Structure
FILING592420Uses Structure
FILING592777Uses Structure
FILING600790Uses Structure
FILING601927Uses Structure
FILING602121Uses Structure
FILING609100Uses Structure
FILING620936Uses Structure