Historical Consolidated Database System

0000087610

BOARD OF TRUSTEES OF SOUTHERN ILLINOIS UNIVERSITY

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID2033579
Application reference number0000087610
ServiceDT
Application typeMP
File prefixBLANK
Call signWMEC
Facility ID70537
CommunityMACOMB, IL
Channel36
StatusGRANT
Status date2019-10-30
Accepted2019-10-30
Cutoff date2019-10-29

Applicant

NameBOARD OF TRUSTEES OF SOUTHERN ILLINOIS UNIVERSITY
FRN0001842533
Address1003 COMMUNICATIONS BUILDING, MAILCODE 6602, CARBONDALE, IL, 62901, US
Phone6184536181
Email[email protected]

Broadcast facility

Facility ID70537
Call signWMEC
ServiceDT
StatusLICEN
Status date2009-05-05
License expiration2021-12-01
Channel36
Frequency602.000000 MHz
CommunityMACOMB, IL

Current LMS continuation

The FCC transfer table maps this historical application to 0000087610.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIBOARD OF TRUSTEES OF SOUTHERN ILLINOIS UNIVERSITY0001842533CARBONDALE, IL, US
CNREPFoster Garvey PCWASHINGTON, DC
APCRTJ Kevin DorseyInterim President
CRTENGreg Best Consulting, Inc.Stilwell, KS

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 36CP MOD / A100.000000 kW ERPN E40.39827778, -90.731805561018309327.100 m AMSL

Call sign history

Call signEffectiveRecord changed
WMEC1989-04-01
WIUM-TV1984-05-07
820510KX

Related FCC records

System or typeRecordRelationship
COMPANYCox Radio, Inc.Filed By
FACILITYFacility 70537Concerns Facility
FILING021008812a2349699051c1b6063ebeb7Concerns Station
FILING0339121d0c1d42bd8e9bc1b6063ebeb7Uses Structure
FILING079bc346bd8248b69c12c1b6063ebeb7Filed By
FILING0fe099354e394a938896c1b6063ebeb7Filed By
FILING1020763Concerns Facility
FILING1027615Concerns Station
FILING1035713Uses Structure
FILING1037059Concerns Facility
FILING103942Concerns Station
FILING1065646Uses Structure
FILING1067637Concerns Facility
FILING1067640Concerns Station
FILING1067647Concerns Facility
FILING107d6b7dd98e49bb8de9cf6212b6c0eaConcerns Facility
FILING1098507Concerns Station
FILING1159017Concerns Facility
FILING1181143Uses Structure
FILING118d0f4ad4f24703a679c1b6063ebeb7Uses Structure
FILING1200763Uses Structure
FILING1219418Concerns Facility
FILING1231059Concerns Station
FILING1255651Concerns Facility
FILING1272549Concerns Station
FILING1275232Concerns Station
FILING1288731Concerns Station
FILING1289316Concerns Facility
FILING1290948Concerns Facility
FILING1294020Concerns Station
FILING1294035Concerns Facility
FILING1305827Concerns Facility
FILING1305846Concerns Station
FILING1323695Concerns Station
FILING1343262Concerns Facility
FILING1408024Concerns Station
FILING1440292Uses Structure
FILING1451335Uses Structure
FILING1454366Concerns Station
FILING1520087Concerns Station
FILING1558404Concerns Facility
FILING1558408Concerns Station
FILING1589111Concerns Facility
FILING1656159Concerns Station
FILING175724Concerns Station
FILING2006007Concerns Facility
FILING2019608Concerns Station
FILING2034067Uses Structure
FILING2034146Filed By
FILING2034225Concerns Facility
FILING2036201Concerns Station
FILING208318Concerns Facility
FILING20a1877d2a8d424daf44c1b6063ebeb7Filed By
FILING20cf41c295254116a628c1b6063ebeb7Concerns Station
FILING2155c943c7704dfa98b0c1b6063ebeb7Filed By
FILING2243d93d0b8744f09460c1b6063ebeb7Filed By
FILING228897Concerns Station