Historical Consolidated Database System

0000078007

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID2022137
Application reference number0000078007
ServiceLD
Application typeSTA
File prefixBLANK
Call signWGDV-LD
Facility ID187979
CommunitySALISBURY, MD
Channel28
StatusGRANT
Status date2019-07-30
Accepted2019-07-13

Applicant

NameMARQUEE BROADCASTING, INC.
Address4400 BROOKEVILLE ROAD, BROOKEVILLE, MD, 20833, US
Phone3016619610
Email[email protected]

Broadcast facility

Facility ID187979
Call signWGDV-LD
ServiceLD
StatusLICEN
Status date2016-09-12
Channel28
CommunitySALISBURY, MD

Current LMS continuation

The FCC transfer table maps this historical application to 0000078007.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIMARQUEE BROADCASTING, INC.BROOKEVILLE, MD, US
APCRTPatricia LanePresident
CRTENCarl E. Smith Consulting Engineers0008539470Bath, OH

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 28CP / A15.000000 kW ERPN H1043201152.400 m AMSL

Call sign history

Call signEffectiveRecord changed
WGDV-LD2016-02-162016-02-16
W32EK-D2012-05-292012-05-29

Related FCC records

System or typeRecordRelationship
FACILITYFacility 187979Concerns Facility
FILING0f457d42fcdd4a4ab6b7cf6212b6c0eaUses Structure
FILING0fde81d78261439ebdfdcf6212b6c0eaConcerns Facility
FILING1234036Uses Structure
FILING1251407Uses Structure
FILING1257838Uses Structure
FILING1271105Uses Structure
FILING1316609Uses Structure
FILING1322990Uses Structure
FILING1324f1e08f7845cd9df9cf6212b6c0eaUses Structure
FILING1395891Concerns Station
FILING1452049Concerns Station
FILING1452385Concerns Station
FILING1693915Concerns Station
FILING1718736Concerns Station
FILING1c6f9b86f5144fe0acb0cf6212b6c0eaConcerns Station
FILING2002826Concerns Facility
FILING2002988Concerns Facility
FILING2003130Concerns Facility
FILING2003197Concerns Facility
FILING2003786Concerns Station
FILING2006271Uses Structure
FILING2011040Concerns Station
FILING2011041Concerns Station
FILING2013920Concerns Facility
FILING2016229Uses Structure
FILING2016772Uses Structure
FILING2034723Concerns Facility
FILING2035807Uses Structure
FILING2036539Uses Structure
FILING2036848Concerns Facility
FILING2039023Uses Structure
FILING2039456Uses Structure
FILING2039904Concerns Station
FILING2039959Uses Structure
FILING2040516Uses Structure
FILING2047020Uses Structure
FILING25076f914e1cdcc3014e27424ec718bbUses Structure
FILING25076f91538b297b0153a025531e1bcaUses Structure
FILING25076f91544e958001550cee398851fbUses Structure
FILING25076f9155269a9501557e83ab4c5cedConcerns Facility
FILING25076f91571f5d14015720759a3702acConcerns Station
FILING25076f91571f5d140157208fa8c702ccConcerns Station
FILING25076f91571f5d140157209192c802daConcerns Station
FILING25076f915cef73c3015d1308d69c2926Uses Structure
FILING25076f916360b30001636fd392212787Uses Structure
FILING25076f916383e2fc0163b854d7b912daConcerns Facility
FILING25076f916bd8cd91016be810846238d1Continued As
FILING422479Uses Structure
FILING497282Uses Structure
FILING528855Uses Structure
FILING562467Uses Structure
FILING667668Uses Structure
STRUCTUREASR 1043201Uses Structure