Historical Consolidated Database System

0000006408

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID2002242
Application reference number0000006408
ServiceDC
Application typeL
File prefixBLANK
Call signDWLPH-CD
Facility ID9614
CommunityMIAMI, FL
Channel44
StatusPRCAN
Status date2017-08-08
Accepted2015-12-03

Applicant

NameLOCUSPOINT WLPH LICENSEE, LLC
Address6200 STONERIDGE MALL ROAD, SUITE 300, PLEASANTON, CA, 94588, US
Phone4153073528
Email[email protected]

Broadcast facility

Facility ID9614
Call signDWLPH-CD
ServiceDC
StatusLICAN
Status date2017-08-08
License expiration2021-02-01
Channel44
CommunityMIAMI, FL

Current LMS continuation

The FCC transfer table maps this historical application to 0000006408.

Application parties

RoleNameFRNLocationRelationship or certification
APPLILOCUSPOINT WLPH LICENSEE, LLCPLEASANTON, CA, US
CNREPWILKINSON BARKER KNAUERWASHINGTON, DC
APCRTIan MilneGeneral Manager - Station Operations
CRTENLocusPoint NetworksPLEASANTON, CA

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 44LIC / A15.000000 kW ERPDIE TUA-M-C3 SPECIAL D H25.97072222, -80.208833331027529275.800 m AMSL

Call sign history

Call signEffectiveRecord changed
WLPH-CD2017-08-09
WLPH-CD2014-02-272014-02-27
WHDT-CD2011-03-242011-03-24
WHDT-LD2009-07-082009-07-08
WHDT-LP2007-07-202007-07-20
WHDT-LP1996-02-01
WHDT-LD1996-02-012007-02-05
W55BO1989-11-24
W25AL1987-09-21
8403087K

Related FCC records

System or typeRecordRelationship
FACILITYFacility 9614Concerns Facility
FILING0109e8f4822a479db48bc1b6063ebeb7Uses Structure
FILING0c9abf1507924c61bdcbcf6212b6c0eaConcerns Station
FILING0c9e56989c39472ea0eecf6212b6c0eaUses Structure
FILING1017422Concerns Station
FILING1017429Concerns Facility
FILING1039db169d2144eba243c1b6063ebeb7Concerns Station
FILING108025Concerns Station
FILING1101531Concerns Facility
FILING1102989Concerns Facility
FILING1107905Uses Structure
FILING1146138Uses Structure
FILING1156799Uses Structure
FILING116889Concerns Facility
FILING119302Concerns Station
FILING11b5fc4a42d74d92bf54c1b6063ebeb7Concerns Facility
FILING124541Concerns Station
FILING1246803Concerns Station
FILING1278989Uses Structure
FILING1295778Uses Structure
FILING1319009Uses Structure
FILING1319012Uses Structure
FILING1324304Uses Structure
FILING1332776Uses Structure
FILING1360091Uses Structure
FILING137504Concerns Station
FILING1391468Concerns Station
FILING1394465Uses Structure
FILING1400280Uses Structure
FILING1400900Uses Structure
FILING141341Concerns Station
FILING1414240Uses Structure
FILING141497Uses Structure
FILING1420534Uses Structure
FILING1442271Uses Structure
FILING1474390Concerns Facility
FILING147457Concerns Station
FILING1476485Concerns Station
FILING1518589Concerns Facility
FILING1518881Concerns Station
FILING1532526Concerns Facility
FILING1580136Concerns Station
FILING1602648Concerns Facility
FILING1624832Concerns Facility
FILING1627873Concerns Station
FILING1630840Concerns Station
FILING1633771Concerns Station
FILING1633773Concerns Facility
FILING164207Concerns Facility
FILING1643255Concerns Station
FILING1643433Concerns Facility
FILING1645007Concerns Facility
FILING1652419Uses Structure
FILING1662676Concerns Facility
FILING1667274Concerns Station
FILING1672169Concerns Facility
FILING1682401Uses Structure