Historical Consolidated Database System

20151119AYW

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID1703763
Application reference number20151119AYW
ServiceFM
Application typeL
File prefixBLED
Call signKLVB
Facility ID70676
CommunityCITRUS HEIGHTS, CA
Channel258
Frequency99.500000 MHz
StatusGRANT
Status date2015-11-30
Accepted2015-11-20

Applicant

NameEDUCATIONAL MEDIA FOUNDATION
Address5700 WEST OAKS BLVD, ROCKLIN, CA, 95765, US
Phone9162511600
Email[email protected]

Broadcast facility

Facility ID70676
Call signKLVB
ServiceFM
StatusLICEN
Status date2012-07-30
License expiration2029-12-01
Channel258
Frequency99.500000 MHz
CommunityCITRUS HEIGHTS, CA

Current LMS continuation

The FCC transfer table maps this historical application to BLED-20151119AYW.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIEDUCATIONAL MEDIA FOUNDATIONROCKLIN, CA, US
CNREPWILKINSON BARKER KNAUER, LLP
APCRTMIKE NOVAKPRESIDENT/CEO
CRTENSTEPHEN WILDEROCKLIN, CARF DESIGN ENGINEER

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
FMChannel 258 / 99.500000 MHzLIC / A / CERI LPX-2E-HW N38.64805556, -121.097500001033381259.000 m HAAT

Call sign history

Call signEffectiveRecord changed
KLVB2010-10-012010-10-01
KSTN-FM2010-03-042010-03-04
KLVS1997-09-02
KJFA1989-09-26
851030MG

Related FCC records

System or typeRecordRelationship
FACILITYFacility 70676Concerns Facility
FILING0123e2afff014bccbceac1b6063ebeb7Concerns Station
FILING024cb57233b24c0595abc1b6063ebeb7Concerns Station
FILING04b3c7071df54865a4f0c1b6063ebeb7Concerns Facility
FILING04d363c15c2948ac95cfc1b6063ebeb7Concerns Facility
FILING0c5ad310f86744dda304c1b6063ebeb7Uses Structure
FILING0cc5039b5c5945f182bec1b6063ebeb7Concerns Station
FILING1071185Concerns Station
FILING1076992Uses Structure
FILING1077922Concerns Station
FILING1080102Uses Structure
FILING108939Concerns Station
FILING1092322Concerns Facility
FILING1166122Uses Structure
FILING1167648Concerns Facility
FILING1173509Uses Structure
FILING1175773Concerns Station
FILING1175798Concerns Station
FILING1178535Uses Structure
FILING1190342Uses Structure
FILING1191800Concerns Facility
FILING1192315Concerns Station
FILING1192599Concerns Facility
FILING1195285Uses Structure
FILING1214744df0684d87aa3fc1b6063ebeb7Concerns Station
FILING1241904Concerns Facility
FILING1242535Concerns Facility
FILING1257952Concerns Station
FILING1273011Uses Structure
FILING128485Concerns Station
FILING1291052Uses Structure
FILING1292564Uses Structure
FILING1303572Uses Structure
FILING1309181Concerns Station
FILING1311912Concerns Station
FILING1317307Uses Structure
FILING1319198Uses Structure
FILING1319873Uses Structure
FILING136161Concerns Station
FILING1361847Concerns Station
FILING1364232Uses Structure
FILING1365881Concerns Station
FILING1390732Uses Structure
FILING1422188Concerns Station
FILING1423014Concerns Facility
FILING1432621Uses Structure
FILING143615Concerns Station
FILING1437815Uses Structure
FILING147b031b91ad407b8aa0c1b6063ebeb7Concerns Station
FILING1492379Concerns Station
FILING1492484Concerns Facility
FILING1509816Concerns Facility
FILING151716Concerns Station
FILING152947Concerns Station
FILING1547975Uses Structure
FILING1560826Concerns Station
FILING1561146Concerns Station
FILING1678154Uses Structure
FILING1678238Concerns Station
FILING1686374Concerns Facility
FILING1686525Concerns Facility
FILING1691648Concerns Facility
FILING1693835Concerns Facility