Historical Consolidated Database System

20121113ANC

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID1523042
Application reference number20121113ANC
ServiceLD
Application typeP
File prefixBPDTV
Call signK08HN-D
Facility ID56696
CommunityASPEN, CO
Channel8
StatusGRANT
Status date2012-11-29
Accepted2012-11-14
Cutoff date2012-11-13
Construction permit expiration2015-11-29

Applicant

NamePITKIN COUNTY TRANSLATOR DEPARTMENT
Address485 RIO GRANDE PLACE #101, ASPEN, CO, 81611
Phone9709205396
Email[email protected]

Broadcast facility

Facility ID56696
Call signK08HN-D
ServiceLD
StatusLICSL
Status date2022-04-05
License expiration2022-04-01
Channel8
Frequency180.000000 MHz
CommunityASPEN, CO

Current LMS continuation

The FCC transfer table maps this historical application to BPDTV-20121113ANC.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIPITKIN COUNTY TRANSLATOR DEPARTMENTASPEN, CO
CNREPGARVEY SCHUBERT BARERWASHINGTON, DC
APCRTJODI SMITHFACILITIES MANAGER
CRTENJON V BANKSGLENWOOD SPRINGS, COTECHNICAL CONSULTANT

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 8CP / A0.006000 kW ERPD39.22583333, -106.835555561242242589.000 m HAAT

Call sign history

Call signEffectiveRecord changed
K08HN-D2010-07-062010-07-06
K08HN

Related FCC records

System or typeRecordRelationship
FACILITYFacility 56696Concerns Facility
FILING0279ddcf94d04b63832ecf6212b6c0eaConcerns Facility
FILING05f929113d714408b3c5cf6212b6c0eaUses Structure
FILING06c129e3d8454038afd0cf6212b6c0eaConcerns Station
FILING0826f3a0a13342498179cf6212b6c0eaUses Structure
FILING098d7ebebc9943b192aacf6212b6c0eaUses Structure
FILING0b79839560044bb7a09ccf6212b6c0eaUses Structure
FILING1019857Uses Structure
FILING110361132def4e8fa787cf6212b6c0eaUses Structure
FILING1126281Uses Structure
FILING1126293Uses Structure
FILING1143613Uses Structure
FILING1143629Uses Structure
FILING1191456Uses Structure
FILING1319031Uses Structure
FILING1319032Uses Structure
FILING1319036Uses Structure
FILING1319038Uses Structure
FILING1319041Uses Structure
FILING1319139Uses Structure
FILING1319423Uses Structure
FILING1319487Uses Structure
FILING1350195Uses Structure
FILING1366750Uses Structure
FILING1366751Uses Structure
FILING1366752Concerns Facility
FILING1366753Uses Structure
FILING1366754Uses Structure
FILING139967Concerns Facility
FILING140393b3ef09403481a4cf6212b6c0eaUses Structure
FILING1473033Concerns Facility
FILING1523040Uses Structure
FILING1523041Uses Structure
FILING1523043Uses Structure
FILING1523044Uses Structure
FILING1523045Uses Structure
FILING1526330Uses Structure
FILING1526334Uses Structure
FILING1526341Uses Structure
FILING1531986Uses Structure
FILING1531994Uses Structure
FILING1532000Uses Structure
FILING1596856Concerns Station
FILING1656666Concerns Station
FILING1657b2025cc44ca1bf74cf6212b6c0eaUses Structure
FILING171014Concerns Station
FILING1a98d04c78fa4166a34bc1b6063ebeb7Concerns Facility
FILING1b4161890aeb456ebb89c1b6063ebeb7Concerns Facility
FILING240749Concerns Facility
FILING262469Concerns Station
FILING305195Concerns Station
FILING626729Uses Structure
FILING995245Uses Structure
FILING995268Uses Structure
FILING995275Uses Structure
FILING99572Concerns Facility
FILING996947Uses Structure
FILING996948Uses Structure
FILING997399Uses Structure
FILING999914Uses Structure
FILING999947Uses Structure
FILINGc333411ad4bc4dc792b9cf6212b6c0eaContinued As
STRUCTUREASR 1242242Uses Structure