Historical Consolidated Database System

20050928AQQ

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID1126330
Application reference number20050928AQQ
ServiceFM
Application typeP
File prefixBPH
Call signWOXY
Facility ID3653
CommunityMASON, OH
Channel249
Frequency97.700000 MHz
StatusGRANT
Status date2006-06-01
Accepted2005-09-30
Construction permit expiration2009-06-01
Amendment stamped2006-04-17

Applicant

NameFIRST BROADCASTING CAPITAL PARTNERS, LLC
Address750 NORTH ST. PAUL, 10TH FLOOR, DALLAS, TX, 75201
Phone2148555582
Email[email protected]

Broadcast facility

Facility ID3653
Call signWOXY
ServiceFM
StatusLICEN
License expiration2028-10-01
Channel249
Frequency97.700000 MHz
CommunityMASON, OH

Current LMS continuation

The FCC transfer table maps this historical application to BPH-20050928AQQ.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIFIRST BROADCASTING CAPITAL PARTNERS, LLCDALLAS, TX
CNREPVINSON & ELKINS, LLPWASHINGTON D.C., DC
APCRTHAL ROSESENIOR VICE PRESIDENT
CRTENW. JEFFREY REYNOLDSSARASOTA, FLTECHNICAL CONSULTANT

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
FMChannel 249 / 97.700000 MHzCP / A / AN39.46333333, -84.376944441012366152.000 m HAAT

Call sign history

Call signEffectiveRecord changed
WOXY

Related FCC records

System or typeRecordRelationship
FACILITYFacility 3653Concerns Facility
FILING00a4503a9069450ebd9fc1b6063ebeb7Concerns Station
FILING048a08596b884552a4b6c1b6063ebeb7Concerns Station
FILING1002885Concerns Station
FILING1019210Concerns Station
FILING1051492Concerns Station
FILING1070321Concerns Station
FILING10874Concerns Station
FILING1089025Concerns Facility
FILING1105918Concerns Facility
FILING110884Concerns Station
FILING1115920Uses Structure
FILING1218485Concerns Station
FILING122313Concerns Facility
FILING129391Concerns Facility
FILING1296851Concerns Facility
FILING129e989f6e1145a7a5d2c1b6063ebeb7Uses Structure
FILING1313087Concerns Station
FILING1380a802dc954d51bc04c1b6063ebeb7Concerns Station
FILING1419804Concerns Station
FILING1495048Concerns Station
FILING1500304Concerns Facility
FILING1500431Concerns Station
FILING1506112Concerns Facility
FILING163fe10bd6a748c5916cc1b6063ebeb7Concerns Station
FILING1655849Concerns Facility
FILING1670084Concerns Facility
FILING1670596Concerns Facility
FILING1674511Concerns Facility
FILING1675315Concerns Station
FILING1710979Concerns Station
FILING178a7e026f8842f4b308c1b6063ebeb7Concerns Station
FILING1795896Concerns Facility
FILING1796586Concerns Station
FILING1798142Concerns Facility
FILING1801775Concerns Facility
FILING1818484Concerns Station
FILING1819869Concerns Station
FILING1b954f2242ce48bc8205c1b6063ebeb7Concerns Facility
FILING1bcdac33483241359265c1b6063ebeb7Concerns Facility
FILING1d479beb34874aec9f0bc1b6063ebeb7Concerns Station
FILING226304Concerns Facility
FILING228f348e1d3d41c797a2c1b6063ebeb7Concerns Station
FILING292814Concerns Station
FILING30304Concerns Facility
FILING43231Concerns Facility
FILING486120Concerns Facility
FILING486121Concerns Facility
FILING486122Concerns Facility
FILING486123Concerns Station
FILING504436Concerns Station
FILING526664Concerns Facility