Historical Consolidated Database System

20041213ABC

This is a historical CDBS record. CDBS stopped receiving current broadcast application updates in October 2023; newer broadcast activity is maintained in LMS.

Application details

CDBS application ID1034074
Application reference number20041213ABC
ServiceDT
Application typeL
File prefixBLCDT
Call signKBSI-DT
Facility ID19593
CommunityCAPE GIRARDEAU, MO
Channel22
StatusGRANT
Status date2005-03-30
Accepted2004-12-16

Applicant

NameKBSI LICENSEE L.P.
AddressC/O SHAW PITTMAN LLP ATTN K SCHMELTZER, 2300 N STREET, NW, WASHINGTON, DC, 200371128
Phone2026638217
Email[email protected]

Broadcast facility

Facility ID19593
Call signKBSI
ServiceDT
StatusLICEN
Status date2009-05-05
License expiration2022-02-01
Channel36
Frequency602.000000 MHz
CommunityCAPE GIRARDEAU, MO

Current LMS continuation

The FCC transfer table maps this historical application to BLCDT-20041213ABC.

Application parties

RoleNameFRNLocationRelationship or certification
APPLIKBSI LICENSEE L.P.WASHINGTON, DC
CNREPSHAW PITTMAN LLPWASHINGTON, DC
APCRTDAVID B. AMYMANAGER OF GENERAL PARTNER
CRTENJOHN E. HIDLE, P.E.SPRINGFIELD, VACONSULTING ENGINEER

Engineering records

ServiceAssignmentStatus / classPowerAntennaCoordinatesASRHeight
TVChannel 22LIC / A435.000000 kW ERPDIE TFU-26GTH-R 3S220 DC D H37.40638889, -89.562222221005390569.000 m HAAT

Call sign history

Call signEffectiveRecord changed
KBSI1982-06-01
810928KH

Related FCC records

System or typeRecordRelationship
FACILITYFacility 19593Concerns Facility
FILING0752e8b065db4260a351c1b6063ebeb7Concerns Facility
FILING085c06c287da4acaa4a8c1b6063ebeb7Concerns Station
FILING094d7510f58e45bc89bbc1b6063ebeb7Concerns Facility
FILING09651d2dcb71402099cccf6212b6c0eaConcerns Facility
FILING0c79c2c8d20642f683d6c1b6063ebeb7Concerns Facility
FILING0ee7a8ecd0494650ae6fc1b6063ebeb7Concerns Station
FILING0ef5d9bea56c4c8eb4e1c1b6063ebeb7Concerns Facility
FILING1025135Concerns Facility
FILING1040073Concerns Station
FILING104471Concerns Station
FILING1047941Concerns Facility
FILING105692Concerns Facility
FILING1069099Concerns Facility
FILING1081253Concerns Station
FILING1081257Concerns Station
FILING1084660Concerns Facility
FILING1094476Concerns Station
FILING1159952Concerns Station
FILING11db6ff2f2ee4344b0dbcf6212b6c0eaConcerns Facility
FILING1204525Concerns Station
FILING1217956Concerns Facility
FILING1233541Concerns Station
FILING1253378Concerns Facility
FILING1269638Concerns Station
FILING1275429Concerns Station
FILING1287249Concerns Facility
FILING1291846Concerns Facility
FILING1292068Concerns Facility
FILING1294730Concerns Station
FILING1297079Concerns Facility
FILING1304252Concerns Facility
FILING1308862Concerns Station
FILING1320204Concerns Station
FILING135211Concerns Station
FILING140c5337b1b4495aa5c1c1b6063ebeb7Concerns Station
FILING177406Concerns Facility
FILING1b9b67a37bb34361b2b1c1b6063ebeb7Concerns Facility
FILING1ed5041781a14b9b9585c1b6063ebeb7Concerns Facility
FILING1f845d1294674898a001c1b6063ebeb7Concerns Station
FILING1fbc5640a2874143b2e9c1b6063ebeb7Concerns Facility
FILING206135Concerns Station
FILING207608Concerns Facility
FILING210787Concerns Facility
FILING213087Concerns Facility
FILING216490Concerns Facility
FILING217683Concerns Facility
FILING2311096efd104ec887a5c1b6063ebeb7Concerns Station
FILING235a9fbe02c04fcf93a4c1b6063ebeb7Concerns Facility
FILING25076f914e4f16d9014e55bde79719e4Concerns Facility